cad

IMPULSE®?G+/VG+ Series 4 Full Brochure
6Pages

{{requestButtons}}

Catalog excerpts

IMPULSE®?G+/VG+ Series 4 Full Brochure - 1

CAPABILITIES IMPULSE®•G+ Series 4 Ratings Class of Service 200-240 Vac, 3.0 to 415 AMP (0.75 to 150 HP) 400-480 Vac, 1.8 to 605 AMP (0.75 to 500 HP) 575-600 Vac, 1.7 to 200 AMP (1 to 200 HP) CMAA Class A-F Service AISE TR6 Class 1 to 4 ASME HST – 4M H1 to H5 Speed Range 40:1 in V/F Mode (15 preset V/F Patterns, 1 Adjustable) 200:1 in Open Loop Vector Mode Speed Control Methods Up to 17 Distinct Speeds (Stepped) 2-Step Infinitely Variable 3-Step Infinitely Variable Analog Signal (0–10 Vdc, 4–20 mA, ±10 Vdc) Digital Pulse Train Input (32 KHz Max) Radio Drive Serial Interface (RDSI) Programmable Terminals (8) 120 Vac Inputs (3) Digital Dry Contact Relay Outputs (1A Max @ 250 Vac, 1A Max @ 30 Vdc, Form A) (1) Dedicated Fault Relay Output (1A Max @ 250 Vac, 1A Max @ 30 Vdc, Form C) (3) Analog Inputs (0-10 Vdc and ±10 Vdc (20K ), 4-20ma (250)) (2) Analog Outputs (0-10 Vdc and ±10 Vdc Max Current 2mA, 4-20ma (500)) (Consult factory for additional analog/digital input/output option cards) Certification UL, cUL, CSA (CE available upon request) Rated input power supply volts 3-phase 200–240 Vac, 380–480 Vac, or 500-600 Vac; 50 or 60 Hz and frequency Allowable input voltage fluctuation +10% or -15% of nominal, 3-phase Allowable input frequency fluctuation ±5% of nominal Control method Fully digital; sine-wave, V/F control, open loop vector control, flux vector control Maximum output voltage (Vac) Max output voltage 3-phase, 200/208/230/240/380/400/415/440/460/480 500/575/600V (proportional to input voltage) Rated output frequency (Hz) 0 to 150 Hz (consult factory for applications above 150 Hz) Output frequency accuracy 0.01% — with digital reference command, -10° to 40°C; 0.1% — with analog reference command; 10 bits/10V; 25°C, ±10°C Traverse Motions Worm Gear and Mechanical Load Brake Hoists IMPULSE®•VG+ Series 4 Ratings Class of Service Speed Range Speed Control Methods Programmable Terminals Applications 200-240 Vac, 3.0 to 415 AMP (0.75 to 150 HP) 400-480 Vac, 1.8 to 605 AMP (0.75 to 500 HP) 575-600 Vac, 1.7 to 200 AMP (1 to 200 HP) CMAA Class A-F Service AISE TR6 Class 1 to 4 ASME HST – 4M H1 to H5 1500:1in Flux Vector Mode Up to 17 Distinct Speeds (Stepped) 2-Step Infinitely Variable 3-Step Infinitely Variable Analog Signal (0–10 Vdc, 4–20 mA, ±10 Vdc) Digital Pulse Train Input/Output (32 KHz Max) Radio Drive Serial Interface (RDSI) (8) 120 Vac Inputs (3) Digital Dry Contact Relay Outputs (1A Max @ 250 Vac, 1A Max @ 30 Vdc, Form A) (1) Dedicated Fault Relay output (1A Max @ 250 Vac, 1A Max @ 30 Vdc, Form C) (3) Analog Inputs (0-10 Vdc and ±10 Vdc (20K), 4-20ma (250)) 2) Analog Outputs (0-10 Vdc and ±10 Vdc Max Current 2mA, 4-20ma (500)) (1) Single line driver/open collector encoder option card with 5/12 Vdc (200ma) power supply (Consult factory for additional analog/digital input/output and encoder option cards) Traverse Motions (Consult factory) Non-Mechanical Load Brake Hoists Frequency reference resolution 0.01 Hz Overload capacity 150% of rated load for 1 minute Remote frequency reference sources 0–10 Vdc (20); 4–20 mA (250); ±10 Vdc; serial (RS-485) Acceleration/deceleration times 0.1 to 25.5 sec — 4 sets; 8 parameters are independently adjustable Braking torque 150% or more with dynamic braking (optional) Electronic thermal overload relay; UL recognized (I2T) Overcurrent protection level (OC) 200% of rated current UNSURPASSED PRODUCT SUPPORT THE NEXT GENERATION OF CRANE PERFORMANCE As always, you can count on Magnetek and IMPULSE® drives to help you achieve the maximum performance and reliability of your overhead material handling system, including: • • • • Three-year warranty Magnetek Service Technicians on-call 24/7/365 On-site and in-house product training programs Fully tested prior to shipment Digital: 0.01 Hz; analog: 0.03 Hz (at 60 Hz) Output frequency resolution Motor overload protection Applications NEW! Specification Value and Information for all IMPULSE®• G+ and VG+ Series 4 Models Circuit protection For more information, contact Magnetek Material Handling or your local Magnetek Sales Representative. Ground fault and blown-fuse protection Overvoltage protection level For maximum control exibility, match the IMPULSE•G+/VG+ Series 4 with SBP®/SBP2® Pendant Pushbutton Stations or Magnetek’s extensive line of Radio Remote Crane Controls. 410 Vdc (200V), 820 Vdc (400V), 1040 Vdc (600V) Undervoltage protection level 190 Vdc (200V), 380 Vdc (400V), 475 Vdc (600V) Heatsink over temperature Thermostat trips at 105°C Four quadrant torque limit selection Separate functions for FORWARD, REVERSE, REGEN; all selectable from 0–300% Stall prevention Separate functions for acceleration, at-speed and constant horsepower region Other protection features Speed deviation, overspeed, mechanical brake failure, lost output phase, lost input phase, failed-oscillator, PG-disconnect, mechanical overload, roll-back detection, internal braking transistor failure, and built in watchdog DC bus voltage indication Charge LED is on until DC bus voltage drops below 50 Vdc Location Indoors; requires protection from moisture, corrosive gases and liquids Ambient operating temperature 14° to 140°F (-10° to 60°C). Consult factory for high ambient applications Storage temperature -4° to 158°F (-20° to 70°C) Humidity 95% relative; noncondensing Vibration 1 G for 10-20 Hz 0.6 G for 20-55 Hz (2003-2180, 4001-4150, 5001-5077) 0.2 G for 20-55 Hz (2215-2415, 4180-41090. 5099-5200) & Elevation 3300 ft. (1000m) or less 9900 ft. (3000m) or less with current derating Safety Standard UL 508C A d j u s t a b l e N49 W13650 Campbell Drive Menomonee Falls, WI 53051 Toll-Free Phone 800.288.8178 Toll-Free Fax 800.298.3503 Phone 262.783.3500 Fax 262.783.3510 email sales@magnetek.com WWW.MAGNETEKMH.COM Pub No. G+_VG+Series4 © Magnetek, Inc. 2011 F r e q u e n c y C r a n e C o n t r o l s

Open the catalog to page 1

All Magnetek catalogs and technical brochures

  1. MH445_SBN

    2 Pages

  2. IMPULSE®?R

    2 Pages

  3. IMPULSE®?T

    2 Pages

  4. ReFlx® 120

    2 Pages

  5. Enrange 300T

    2 Pages

  6. MAC.2000

    2 Pages