Radar Non-Contact Level Sensors (R Series)
4Pages

{{requestButtons}}

Catalog excerpts

Radar Non-Contact Level Sensors (R Series) - 1

R Series Radar Level Sensors Madison Company offers a series of low-cost radar sensors for continuous level measurement. This product series offers a logical extension to the ultrasonic sensor series, where application conditions are in need of non-contact liquid level measurement, and where ultrasonic level measurement is not acceptable. As with all Madison products, this radar technology can be designed for your specific level measurement needs, providing unique considerations for materials to be measured, vessel configuration and system interface. These radar level sensors are ideal for reflective liquids that have a foaming surface or vapor conditions beyond ultrasonic wave capabilities. Features • • • • • Non-contact measurement Continuous level measurement Pulse radar measurement range 10” to 100’ (0.254m to 30m) Networkable, multi-sensor with available software Programmable and push-button calibration NC Applications • Various liquids and solids Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • info@madisonco.com • www.madisonco.com © Copyright Madison Company – 6/08 NC-19

Open the catalog to page 1
Radar Non-Contact Level Sensors (R Series) - 2

Specifications Electrical: Power Options – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC R load = (Vs–6)/24 mA Output – 4-20 mA, 6.1 uA resolution; 750 ohms Optional RS232 or RS485 communications port Operational: Accuracy – ±0.25% of max. target range (in air) Frequency – 5.8 GHz or 6.3 GHz Loss of Echo Hold – 30 seconds, 22 mA output Transmitter Power – 50 uW average Calibration – Programmable via communications port Diagnostics (Echo Profile) – Via programmable port Antenna – Dielectric rod Environmental: Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F) Installation Category –...

Open the catalog to page 2
Radar Non-Contact Level Sensors (R Series) - 3

Standard sanitary unit features aluminum housing, Sanitary "Smart" Radar Level Measurement Sensors Minimum distance starts at the lower tip of the antenna. Programmable and push-button calibration Output: 4-20 mA/20-4 mA (isolated on 4-wire models only) Madison Company • (203)488-4477 • (800)466-5383 • Fax (203) 481-5036 • info@madisonco.com • www.madisonco.com © Copyright Madison Company - 6/10 NC-21

Open the catalog to page 3
Radar Non-Contact Level Sensors (R Series) - 4

Specifications Electrical: Power – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC R Load = (Vs–6)/24 mA Output – 4-20 mA output, 6.1 uA resolution; 750 ohms RS232 or RS485 communications port Operational: Operation – Pulse radar Accuracy – ± 0.1% of maximum range in lab using 4-20 mA current output ± 0.25% of maximum range (typically in field) Frequency – 5.8 GHz or 6.3 GHz Loss of Echo Hold – 30 seconds, 22 mA output time Transmitter Power – 50 uW average Calibration – Programmable via communications port or push button Diagnostics (Echo Profile) – Via communications port Antenna Dielectric Rod...

Open the catalog to page 4