1. Catalogs
  2. Madison Company
  3. Radar Non-Contact Level Sensors (R Series)

Radar Non-Contact Level Sensors (R Series)

Radar Non-Contact Level Sensors (R Series)

Radar Non-Contact Level Sensors (R Series)

Product catalog summary
Overview: Madison Company offers a series of low-cost radar sensors designed for continuous level measurement, particularly suitable for applications where non-contact liquid level measurement is required, and ultrasonic sensors are not viable. These sensors are ideal for reflective liquids with foaming surfaces or vapor conditions.
Features:
  • Non-contact and continuous level measurement.
  • Pulse radar measurement range from 10 inches to 100 feet (0.254m to 30m).
  • Networkable with multi-sensor capabilities and available software.
  • Programmable and push-button calibration.
Applications: Suitable for various liquids and solids, including food and beverage, water, and pharmaceuticals.
Electrical Specifications:
  • Power Options: 12 to 30 VDC, 0.07 Amps max at 24 VDC.
  • Output: 4-20 mA with 6.1 uA resolution; optional RS232 or RS485 communications port.
Operational Specifications:
  • Accuracy: ±0.25% of max target range in air.
  • Frequency: 5.8 GHz or 6.3 GHz.
  • Transmitter Power: 50 uW average.
  • Calibration and diagnostics via communications port.
Environmental Specifications:
  • Operating Temperature Range: -40˚C to 60˚C (-40˚F to 140˚F).
  • Installation Category: Class II.
  • Approvals: FCC Part 15 and CE for 5.8 GHz models.
Mechanical Specifications:
  • Conduit Entry: 1/2” NPT standard.
  • Housing: Aluminum or optional stainless steel 316L.
  • Ingress Protection: NEMA 4 (IP65).
Options:
  • PTFE antenna or sanitary PTFE antenna.
  • 1.5” or 2” NPT PTFE decoupler for high-temperature applications.
  • Sanitary designs and antenna extensions available.
Sanitary "Smart" Radar Level Measurement Sensors:
  • Programmable and push-button calibration.
  • Output: 4-20 mA/20-4 mA, PLC compatible (Modbus RTU).
  • Standard sanitary unit features aluminum housing and polypropylene antenna.
Model Specifications:
  • R3-50S: 3-wire, DC, range up to 50 feet (15m), resolution 0.22 inches (5.7mm).
  • R3-100S: 3-wire, DC, range up to 100 feet (30m), resolution 0.44 inches (11mm).
Process Specifications:
  • Temperature: PTFE Rod -40˚C to 204˚C (-40˚F to 400˚F) with tri-clamp.
  • Pressure: 1-10 BAR, 15-150 PSI.
Contact Information: Madison Company, 27 Business Park Drive, Branford, CT 06405, Phone: 800-466-5383, Email: [email protected]
See more

Catalog excerpts

Radar Non-Contact Level Sensors (R Series)-1

R Series Radar Level Sensors Madison Company offers a series of low-cost radar sensors for continuous level measurement. This product series offers a logical extension to the ultrasonic sensor series, where application conditions are in need of non-contact liquid level measurement, and where ultrasonic level measurement is not acceptable. As with all Madison products, this radar technology can be designed for your specific level measurement needs, providing unique considerations for materials to be measured, vessel configuration and system interface. These radar level sensors are ideal for reflective liquids that have a foaming surface or vapor conditions beyond ultrasonic wave capabilities. Features • • • • • Non-contact measurement Continuous level measurement Pulse radar measurement range 10” to 100’ (0.254m to 30m) Networkable, multi-sensor with available software Programmable and push-button calibration NC Applications • Various liquids and solids Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com © Copyright Madison Company – 6/08 NC-19

 Open the catalog to page 1
Radar Non-Contact Level Sensors (R Series)-2

Specifications Electrical: Power Options – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC R load = (Vs–6)/24 mA Output – 4-20 mA, 6.1 uA resolution; 750 ohms Optional RS232 or RS485 communications port Operational: Accuracy – ±0.25% of max. target range (in air) Frequency – 5.8 GHz or 6.3 GHz Loss of Echo Hold – 30 seconds, 22 mA output Transmitter Power – 50 uW average Calibration – Programmable via communications port Diagnostics (Echo Profile) – Via programmable port Antenna – Dielectric rod Environmental: Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F) Installation Category – Class...

 Open the catalog to page 2
Radar Non-Contact Level Sensors (R Series)-3

Standard sanitary unit features aluminum housing, Sanitary "Smart" Radar Level Measurement Sensors Minimum distance starts at the lower tip of the antenna. Programmable and push-button calibration Output: 4-20 mA/20-4 mA (isolated on 4-wire models only) Madison Company • (203)488-4477 • (800)466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com © Copyright Madison Company - 6/10 NC-21

 Open the catalog to page 3
Radar Non-Contact Level Sensors (R Series)-4

Specifications Electrical: Power – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC R Load = (Vs–6)/24 mA Output – 4-20 mA output, 6.1 uA resolution; 750 ohms RS232 or RS485 communications port Operational: Operation – Pulse radar Accuracy – ± 0.1% of maximum range in lab using 4-20 mA current output ± 0.25% of maximum range (typically in field) Frequency – 5.8 GHz or 6.3 GHz Loss of Echo Hold – 30 seconds, 22 mA output time Transmitter Power – 50 uW average Calibration – Programmable via communications port or push button Diagnostics (Echo Profile) – Via communications port Antenna Dielectric Rod –...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.