Water Analysis NANOCOLOR analysis system NANOCOLOR® analysis system nn Expertise nn Continuity nn Passion www.mn-net.com www.mn-net.com

 Open the catalog to page 1

NANOCOLOR® analysis system 40 years of expertise, continuity and passion for our customers For over 40 years, MACHEREY-NAGEL has been developing solutions in the field of photometry. Continuous equipment and software development, extraordinary close customer relations and passion for our work allow us to offer you the NANOCOLOR® system with high reliability and quality. nnISO-certified production in Germany ensuring highest quality “Made in Germany“ nnConsistent quality from batch to batch – no LOT-specific updates required nnSDS, user manuals and LOT-specific certificates nnIntensive...

 Open the catalog to page 2

Test tubes in convenient packaging for safe and easy handling NANOCOLOR® reagents impress by easy handling and are suited for routine analysis, self-monitoring and process control. 16 mm round tubes with pre-dosed reagents guarantee a maximum safety for the user. ■ Rugged boxes with perfect light protection ■ Color-coded labels with all important information ■ Colored pictograms on package lid for perfect test execution ■ Convenient and safe removal of test tubes ■ Describable top-label enabling an explicit allocation of test tubes ■ Wide test tube openings for easy handling and safe...

 Open the catalog to page 3

NANOCOLOR® analysis system The perfect COD test for each and every user For one of the most important parameters for determination of industrial and municipal waste water MACHEREY-NAGEL offers you even 12 different tests and measurement ranges. At the same time our COD tests allow safe handling without any risk from escaping dichromate and mercury gases. Even after the REACH restrictions in 2017, our customers can continue using our NANOCOLOR® COD cuvette tests without limitation. nn12 measurement ranges for all requirements and demands nnReaction base according to ISO 6060 nn7 COD tests...

 Open the catalog to page 4

Time-saving and reliable analysis of total nitrogen The proven NANOCOLOR® total nitrogen tests are perfectly suited for the reliable determination of total nitrogen in waste water. Beside reproducible results they offer you a very simple and fast handling. ■ One single test tube for each digestion ■ Less testing steps through prefilled digestion reagents ■ No contamination since digestion tubes are never used twice ■ No cleaning of digestion tubes required ■ Safe results through sufficiently large sample volumes

 Open the catalog to page 5

NANOCOLOR® analysis system Smart photometry Spectrophotometers NANOCOLOR® UV/VIS II and VIS II MACHEREY-NAGEL is revolutionizing your daily laboratory work with the spectrophotometers NANOCOLOR® UV/VIS II and NANOCOLOR® VIS II and combines a superior quality, high-tech electronic device with an outstanding usability. Operate this innovative photometers like your smartphone or tablet and enjoy the intuitive, icon-based operation every day in a new way. Due to the clearly arranged and high-resolution touch screen display, the daily measurement routine will become a pleasure. nnRevolutionary...

 Open the catalog to page 6

NANOCOLOR® analysis system Automatic turbidity check for tube tests Despite careful working procedures and constant quality control, turbidity is often underestimated as a source of error in photometric water analysis which can lead to significant deviations in measuring values up to 30 %. To increase result safety for users, MACHEREY-NAGEL has integrated a unique turbidity control function (NTU-Check) for tube tests into our spectrophotometers. nnInnovative and unique solution for turbidity problems, warns in case of potential interferences nnElimination of a frequently underestimated...

 Open the catalog to page 7

Convenient data export to LIMS and other standard PC-programs In modern laboratories dealing with water and waste water analysis, the combination of the different data sets and test results is getting more and more important. Using the free of charge NANOCOLOR® PC software, the data from NANOCOLOR® spectrophotometers can be elegantly integrated into various laboratory information systems. This is going to be easier and even more efficient employing novel photometer updates. ■ Free of charge PC software with numerous additional features ■ Easy data transfer to Microsoft® Excel ■ Automated...

 Open the catalog to page 8

Future-proof heating blocks for reliable sample digestion The NANOCOLOR® heating blocks enable a fast and safe performance of all required digestions. The preprogrammed standard parameter for all routine digestions, e.g., for COD, TOC, total nitrogen, total phosphate and metals help avoid errors. ■ 2 separate heating units for parallel rapid digestion of COD, total nitrogen and total phosphate ■ Touch screen with intuitive menu navigation for easy handling ■ Lockable protective lids and safety covers for maximum protection ■ USB interface for future-proof PC connection ■ Graphical...

 Open the catalog to page 9

NANOCOLOR® analysis system NANOCOLOR® USB T-Set and T-Set Automatic heating block control and calibration The unique NANOCOLOR® T-Set is an electronic temperature sensor for temperature control and fully automatic calibration of the heating blocks. The user can check the heating blocks independently with the NANOCOLOR® T-Set for internal quality control purposes. nnCalibrated temperature sensors made to monitor digestion temperatures nnEasy monitoring of temperature stability through external recordings of heating curves nnNANOCOLOR® T-Set also suitable as a universal thermometer for...

 Open the catalog to page 10

Quality control for photometric water analysis With the NANOCONTROL system MACHEREY-NAGEL offers you a complete range of products for analytical quality control for all analyses carried out with our NANOCOLOR® system. It gives you options to check all NANOCOLOR® reagents and test kits, photometers, heating blocks and your personal handling and work flow, thus providing 360 degree feedback on your analytical work. ■ Measurement of single and multi standards with NANOCONTROL ■ Plausibility checks with NANOCONTROL addition solutions ■ Heating block inspection with the NANOCOLOR® T-Set ■...