Series 37 - 1

Direct solenoid and solenoid pilot operated valvesSeries 37 individual mounting Series Inline Manual operator Armature Coil Push pin Pole piece "D" seal Poppet Valve return spring SERIES FEATURES • Balanced poppet equals consistent high shifting forces. • Valve shifting forces are consistent and independent of pressure fluctuations. • High solenoid and return spring forces ensure high speed and precise repeatability. • Built-in wear compensation - valve stroke is shorter than solenoid stroke. • Constant high flow maintained throughout the pressure range. • Exhaust contaminants are isolated from the solenoid. • Full flow exhaust. • Universal porting - 6 functions in one valve. Consult "Precautions" page 327 before use, installation or service of MAC Valves..

Open the catalog to page 1
Series 37 - 2

Direct solenoid and solenoid pilot operated valves Series 37 Function Port size Flow [Max] Individual mounting OPERATIONAL BENEFITS 1. Balanced poppet equals consistent high shifting forces. 2. Valve shifting forces are consistent and independent of pressure fluctuations. 3. High solenoid and return spring forces ensure high speed and precise repeatability. 4. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 5. Constant high flow maintained throughout the pressure range. 6. Exhaust contaminants are isolated from the solenoid. 7. Full flow exhaust. 8....

Open the catalog to page 2
Series 37 - 3

TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 5.2 W coil) Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p 0°F to 120°F (-18°C to +50°C) 5.2 W : (0.5 Cv) - 2.4 W : (0.35 Cv) Class A wire (#22 AWG x 18), continuous duty -15% to +10% of nominal voltage 5.2 W - 2.4 W Energize : 16.9 ms De-energize : 6.7 ms Options : • BSPP ports Dimensions shown are metric (mm) Shown with Mini Square Connector...

Open the catalog to page 3
Series 37 - 4

Direct solenoid and solenoid pilot operated valves Series 37 Function Port size Flow [Max] Individual mounting Series OPERATIONAL BENEFITS 1. Balanced poppet equals consistent high shifting forces. 2. Valve shifting forces are consistent and independent of pressure fluctuations. 3. High solenoid and return spring forces ensure high speed and precise repeatability. 4. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 5. Constant high flow maintained throughout the pressure range. 6. Exhaust contaminants are isolated from the solenoid. 7. Full flow exhaust. 8....

Open the catalog to page 4
Series 37 - 5

Series 37 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : Class A wire (#22 AWG x 18), continuous duty Voltage range : Response times : • BSPP ports • Sandwich regulator - see “Regulator” Section Dimensions shown are metric (mm) G CIRCUIT BOARD OPTION FLYING LEAD OPTION (SHOWN WITH 1/4" PORTS) (SHOWN WITH 1/8" PORTS) 17.5 WIDE VALVE BODY 17.5 & 19.5 WIDE VALVE BODIES PLUG-IN OPTION (SHOWN WITH 1/8" PORTS) 19.5 WIDE VALVE BODY Consult “Precautions” page 327 before...

Open the catalog to page 5
Series 37 - 6

Codification table for voltages / Manual operators / Electrical connections - Solenoid valves 37 & 47 Series Consult “Precautions” page 327 before use, installation or service of MAC Valves

Open the catalog to page 6
Series 37 - 7

BL BA with full wave rectifier & ground wire VOLTAGE BT BA with full light (use connector with rectifier) H-XX X-X XX PLUG-IN CONNECTOR FA Base plug-in FB FA with ground wire FC FA with light FD FA with light & ground wire FE FA with suppression diode FF FA with suppression diode & ground wire FG FA with suppression diode & light FH FA with suppression diode plus light & ground wire FK FA with full wave rectifier FL FA with full wave rectifier & ground wire *FN FA with suppression diode plus blocking diode *FP FA with suppression diode...

Open the catalog to page 7

All MAC Valves catalogs and technical brochures

  1. PV03 Series

    3 Pages

  2. Series 38

    15 Pages

  3. Series 72

    4 Pages

  4. Series 77

    6 Pages

  5. Series 100

    13 Pages

  6. Series 200

    18 Pages

  7. Series 1100

    5 Pages

  8. 92 MAConnect

    20 Pages

  9. 82 series

    24 Pages

  10. 77 series

    6 Pages

  11. 82 MAConnect

    24 Pages

  12. Bullet Valve

    24 Pages

  13. 38 series

    15 Pages

  14. 33 series

    5 Pages

  15. 32 series

    17 Pages

  16. 35L

    14 Pages

  17. 31 series

    9 Pages

  18. 700

    10 Pages

  19. 1100

    5 Pages