Catalog excerpts
DISC VALVE HYDRAULIC MOTORS CONTENTS Page “M+S HYDRAULIC” can accept no responsibility for possible errors in catalogues, brochures and other printed material. “M+S HYDRAULIC” reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
Open the catalog to page 2DISC VALVE HYDRAULIC MOTORS GENERAL INFORMATION: Orbit motors convert hydraulic energy (pressure, oil flow) into mechanical energy (torque, speed). Hydraulic orbit motors operate on the principle of an internal gear (rotor) rotating within a fixed external gear (stator). The internal gear transmits the torque generated by the application of pressure from hydraulic oil fed into motor which is then delivered via the motor's output shaft. Orbit motors have high starting torque and constant output torque at wide speed range. The output shaft runs on tapered roller bearings and can absorb high...
Open the catalog to page 3HYDRAULIC MOTORS MS APPLICATION » » » » » » » Conveyors Metal working machines Agricultural machines Road building machines Mining machinery Food industries Special vehicles etc. » Model - Disc valve, roll-gerotor » Flange and wheel mount » Short motor » Motor with Drum Brake » Tacho connection » Speed sensoring » Side and rear ports » Shafts - straight, splined and tapered » SAE, Metric and BSPP ports » Other special features daNm [lb-in] Max. Pressure Drop, Max. Oil Flow, Permissible Shaft Loads Pressure fluid Mineral based- HLP(DIN 51524) or HM(ISO 6743/4) Temperature range, Optimal...
Open the catalog to page 4SPECIFICATION DATA Displacement, cm³/rev [in³/rev] [RPM] Max. Torque daNm [lb-in] Max. Output kW [HP] Max. Pressure Drop bar [PSI] with Drain Line Max. Starting Pressure with Unloaded Shaft, bar [PSI] at max. press. drop cont. daNm [lb-in] Min. Speed***, [RPM] Weight, kg [lb] For Rear Ports + 0,40 [.88] * Intermittent operation: the permissible values may occur for max. 10% of every minute. ** Peak load: the permissible values may occur for max. 1% of every minute. *** For speeds lower than given, consult factory or your regional manager. 1. Intermittent speed and intermittent pressure must...
Open the catalog to page 5SPECIFICATION DATA (continued) Displacement, cm³/rev [in³/rev] daNm [lb-in] with Drain Line Max. Starting Pressure with Unloaded Shaft, bar [PSI] Min. Starting Torque at max. press. drop cont. 56 [4960] daNm [lb-in] * Intermittent operation: the permissible values may occur for max. 10% of every minute. ** Peak load: the permissible values may occur for max. 1% of every minute. *** For speeds lower than given, consult factory or your regional manager. 1. Intermittent speed and intermittent pressure must not occur simultaneously. 2. Recommended filtration is per ISO cleanliness code 20/16. A...
Open the catalog to page 6FUNCTION DIAGRAMS The function diagrams data is for average performance of randomly selected motors at back pressure o 5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122 F]. 7
Open the catalog to page 7FUNCTION DIAGRAMS The function diagrams data is for average performance of randomly selected motors at back pressure o 5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122 F]. 8
Open the catalog to page 8FUNCTION DIAGRAMS The function diagrams data is for average performance of randomly selected motors at back pressure o 5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122 F]. 9
Open the catalog to page 9FUNCTION DIAGRAMS The function diagrams data is for average performance of randomly selected motors at back pressure o 5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122 F]. 10
Open the catalog to page 10FUNCTION DIAGRAMS The function diagrams data is for average performance of randomly selected motors at back pressure o 5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122 F]. 11
Open the catalog to page 11FUNCTION DIAGRAMS The function diagrams data is for average performance of randomly selected motors at back pressure o 5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122 F].
Open the catalog to page 12DIMENSIONS AND MOUNTING DATA MS, MSF, MSA, MSW Port A Port B Port Dim. See Page 16 mm [in] C: 2xM10-12 mm [.47 in] depth P(A,B): 2xG1/2 or 2xM22x1,5-15 mm [.59 in] depth T: G ¼ or M14x1,5- 12 mm [.47 in] depth (plugged) Standard Rotation Viewed from Shaft End Port A Pressurized - CW Port B Pressurized - CCW Reverse Rotation Viewed from Shaft End Port A Pressurized - CCW Port B Pressurized - CW * -For Rear Ported Motors. 13
Open the catalog to page 13DIMENSIONS AND MOUNTING DATA - MSQ SL Shaft C Shaft C Port A Port Dim. See Page 16 Standard Rotation Viewed from Shaft End Port A Pressurized - CW Port B Pressurized - CCW C: 2xM10-12 mm [.47 in] depth P(A,B): 2xG1/2 or 2xM22x1,5-15 mm [.59 in] depth T: G ¼ or M14x1,5- 12 mm [.47 in] depth (plugged) Type * -For Rear Ported Motors. 14 Reverse Rotation Viewed from Shaft End Port A Pressurized - CCW Port B Pressurized - CW
Open the catalog to page 14MOUNTING SAE A-4 Mount (4 Holes) 6,1±0,25 [.24±.0098] Q Square Mount (4 Holes) F Magneto Mount (4 Holes)
Open the catalog to page 15Side Ports Reverse Rotation Viewed from Shaft End Port A Pressurized - CCW Port B Pressurized - CW C: 2xM10-12 mm [.47 in] depth P(A,B): 2xG1/2 or 2xM22x1,5-15 mm [.59 in] depth T: G ¼ or M14x1,5- 12 mm [.47 in] depth (plugged) MOTORS WITH TACHO CONNECTION max L Standard Rotation Viewed from Shaft End Port A Pressurized - CW Port B Pressurized - CCW
Open the catalog to page 16SHAFT EXTENSIONS K - tapered 1:10, Parallel key B6x6x20 DIN 6885 Max. Torque 95 daNm [8400 lb-in] Max. Torque 95 daNm [8400 lb-in] Max. Torque 20 daNm [1770 lb-in] Max. Torque 77 daNm [6815 lb-in] 76±1 [2.992±.039] Max. Torque 77 daNm [6815 lb-in] S=41 Tightening torque 20±1 daNm [1770±88.5 lb-in] Max. Torque 77 daNm [6815 lb-in] MAX. PERMISSIBLE SHAFT SEAL PRESSURE Max. return pressure without drain line or max. pressure in the drain line 1: Drawing for Standard Shaft Seal 2: Drawing for High Pressure Seal ("U" Seal) - continuous operations - intermittent operations
Open the catalog to page 17All M+S Hydraulic PLC catalogs and technical brochures
-
E5-STEERINGUNIT
54 Pages
-
E4-ACCESSORIES
67 Pages
-
E3-HEAVY DUTY
53 Pages
-
E1-SPOOLVALVE
123 Pages
-
HEAVY DUTY HYDRAULIC MOTORS
53 Pages
-
Hydraulic Motors MLHS MLHT MLHV
55 Pages
-
Hydraulic Motors MLHM MLHP MLHR MLHH
103 Pages