Gas Sample Probe Series SP® ^5^ Electrically heated, compact version with weather protection cover and test gas connection as standard SP180-H-EX2 T2, SP180-H-EX2 T3, SP180-H-EX2 T4 SP180-H-EX1 T2, SP180-H-EX1 T3, SP180-H-EX1 T4 SP180-H Special Features ■ Sampling of dust loaded process gases ■ Small volume, fast response time ■ Easy mounting and maintenance ■ Self-regulated electrical heating ■ Three EX-Versions: SP180-H-EX2 T2 to T4 with Ex-certification according to ATEX, suitable for use in Ex zone 2 ■ Three EX-Versions: SP180-H-EX1 T2 to T4 with Ex-certification according to ATEX, suitable for use in Ex zone 1 ■ IECEX for zone 1 ■ Alarm contact for low temperature ■ With new isolation cover for outdoor mounting ■ Test gas connection according to EN14181 for test gas feeding via filter element available as standard ■ In-situ probe tube optional Application The M&C gas sample probe version SP180-H... is applicable for continuous gas sampling. The compact design requires only limited space. The gas sample probe is equipped with a new protective cover and thus also suitable for outdoor mounting. Description The design of the M&C probe version SP180-H... guarantees simple mounting, safe operation and problem-free maintenance. Changing the external filter element needs no tools and no disassembling of the sample line. For the change of the filter element the complete filter assembly is removed out of the probe head. Easy checkup of the filter element and the gaskets, cleaning the filter area of the probe head respectively the insitu probe tube without dismounting the sample probe are only a few advantages of the M&C probe. In the heated filter housing out of stainless steel the 2 micron ceramic filter element is located. More filter element materials are available as option. The compact design and the new all-round heat insulation and weather protection ensures an optimized heat distribution as well as safe operation without dew point lower deviation in the filter or flange area. The gas sample probe can be heated up to 180 °C [356 °F] with special self-regulating heating elements within a range of 110 V to 240 V without switching. No temperature controller respectively temperature limitation is necessary. The separate thermo switch enables a low temperature monitoring (<160 °C [320 °F], NO). For electrical connection a junction box with terminals is mounted. The gas sample probe SP180-H... has a calibration gas connection as standard according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The versions SP180-H-EX2 T2, SP180-H-EX2 T3 and SP180-H-EX2 T4 are suitable for usage in Ex zone 2. The alarm contact for low temperature corresponds to the temperature classes of the Ex-versions. The versions SP180-H-EX1 T2, SP180-H-EX1 T3 and SP180-H-EX1 T4 are suitable for usage in Ex zone 1. The alarm contact for low temperature corresponds to the temperature classes of the Ex-versions. The stainless steel insitu probe tube SP210/ SS (option) is screwed into the DN65 PN6 mounting flange. The maximum operating temperature of the tube out of stainless steel is 600 °C [1112 °F]. The non-explosion-proof version SP180-H can be used in combination with the heated probe tubes SP30-H or SP35-H (see data sheet 2.15) for long and cold connection pieces or for process temperatures lower than the dew point. For solution of specific sampling problems you can find more filter elements, probe tubes and pre-filters in our wide range of M&C probe accessories (data sheets 2.14 and 2.17). Technical specifications and illustrations are without    M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany obligation, subject to modifications. 07.18 - 1.03.00    info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +4

 Open the catalog to page 1

Technical Data SP180-H, SP180-H-EX2 Series SP® Part No. Protective cover Outdoor mounting Sample temperature Sample pressure Ambient temperature Connection sample outlet Connection calibration gas / back purge Power supply Power consumption Electrical connection Mounting flange Material of sample contacting parts Degree of protection / Electrical equipment standard Yes Max. 600 °C [1112 °F]* 0.4 to 6 bar abs. (-40 °C) -25 °C to +80 °C** -20 °C to +80 °C -20 °C to +80 °C ((~-40 °F) ~-13 °F to [~-4 to +176 °F] [~-4 to +176 °F] +176 °F]** Max. 1 g/m3 70 ml type S-2K, filter porosity 2 µm,...

 Open the catalog to page 2

Protective cover    yes Outdoor mounting    yes Sample temperature    Max. 600 °C [1112 °F]* Dust load    Max. 1 g/m3 Filter chamber volume    70 ml Filter element    Type S-2K, filter porosity 2 |jm, ceramic (others on request) self-regulating    self-regulating    self-regulating Ready for operation    After 2 hours Low temperature alarm contact, alarm point    < 130 °C [266 °F], NO    < 130 °C [266 °F], NO    < 90 °C [194 °F],    NO Low temperature alarm contact, contact rating    250 V - 1.5 A AC Connection sample outlet    1/4"-NPT inside with Swagelok tube connector 0 6 x 1 mm (DN4/6)...

 Open the catalog to page 3

All M&C TechGroup Germany GmbH catalogs and technical brochures

  1. Pump series MP

    4 Pages

  2. Cooler EC30C

    3 Pages

  3. ECPX000C

    4 Pages

  4. FPF-0.1GF

    2 Pages

  5. FP-2GF

    4 Pages

  6. SP2000/V20

    3 Pages

  7. SP2000/PV

    2 Pages

  8. PSP4000-H

    4 Pages

  9. SP3000/Ex

    4 Pages

  10. PSP4000-H/C

    4 Pages

  11. SP3200/EX

    6 Pages

  12. SP3100/EX

    6 Pages

  13. SP2500-H/C/I/BB

    4 Pages

  14. SP2020-H

    2 Pages

  15. SP2200-H/C/I/BB

    2 Pages

  16. SP2300-H

    4 Pages

  17. SP10-H

    3 Pages

  18. SP10

    3 Pages

  19. SP2100-H

    2 Pages

Archived catalogs

  1. SP3000/EX

    4 Pages