Peltier Gas Cooler Series ECP® - 1

Embracing Challenge Peltier Gas Cooler Series ECP® Version ECP1000C with 1 x 150 Nl/h Version ECP2000C with 2 x 150 Nl/h Version ECP3000C with 1 x 350 Nl/h Special Features ■ Ambient temperature from +5 to +50 °C [41 to 122 °F] (no extra charge) ■ Outlet dew point adjustable from +2 to +15 °C [35.6 °F to 59 °F] ■ Dew point stability ± 0.1 °C [± 0.18 °F] ■ Control setpoint selectable between: absolute value mode or AT mode ■ Optional measurement of the gas outlet temperature in the gas path ■ Ready for use in less than 3 minutes ■ Option: configurable mA output (no shielding necessary) ■ Integrated evaluation for liquid alarm sensors ■ Configurable, potential-free alarm output ■ Universal power supply ■ Mounting option for up to two SR25.2-W peristaltic pumps below the unit ■ Compact design, low weight ■ Jet-Stream heat exchangers available in various materials ■ Compatible with previous version Application The M&C gas coolers of the ECP® series are used in analytical technology to reduce the dew point of humid gases in order to prevent condensation in the analyzer. By setting an extremely stable gas outlet dew point, water vapor cross-sensitivities and volumetric errors are minimized. The compact, lightweight design makes the ECPX000C units particularly suitable for portable and compact stationary gas conditioning systems. Description With the upgraded version ECPX000C, M&C combines the solid advantages of the ECPX000 devices with new future-oriented features, a significant increase in cooling capacity, more functions and improved service friendliness. The ECPX000C gas cooler can be operated in ambient temperatures of up to 50 °C as standard. It is characterized by a very high dew point stability of < ±0.1 °C. The broadband power supply makes the cooler universally usable. Plug-in electrical connections for power and alarm relays are standard. The connections of the configurable mA outputs (optional) are also supplied as plug-in versions. The ECPX000C is equipped with a wear-free, capacitive control and display panel for improved handling of the cooler. The absolute value control implemented by the previous ECPX000 version has been extended by the differential temperature mode. The cooling capacity has almost doubled compared to the previous version. The ECPX000C gas cooler is ready for use in less than 3 minutes under normal operating conditions. The housings of the three ECPX000C devices have the same compact dimensions and are compatible with previous versions. The units can be opened from the front for easier maintenance. The condensate can be discharged externally by peristaltic pumps, traps or collecting vessels. Up to two peristaltic pumps for condensate removal can be mounted directly below the unit. Technical specifications and illustrations are without obligation, subject to modifications. 10.18 - 1.03.01 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-

Open the catalog to page 1
Peltier Gas Cooler Series ECP® - 2

* Drawing shows ECP2000C with two optional SR25.2-W peristaltic pumps Dimensions in mm [inches] Heated sample line 4M4/6 Universal filter FP-2T-D with liquid alarm LA1 Aerosol filter CLF-5/W optional according to application 5 Alternative: trap with float or condensate collection vessel Technical Data Gas Cooler Series EC® Part No. without heat exchangers Number of possible heat exchangers Gas flow rate per heat exchanger Ambient temperature Storage temperature Sample outlet dew point Dew point stability Sample inlet temperature Gas inlet water vapor saturation Total cooling capacity at +25...

Open the catalog to page 2
Peltier Gas Cooler Series ECP® - 3

Part No. without heat exchangers Ready for use Max. loudness Electrical connection Signal input and output Status alarm: 2 changeover contacts Case protection Electrical standard EMC standard Case color Method of mounting Case dimensions (W x H x D) Weight without heat exchangers < 3 min. (at 25 °C ambient temperature and with no load applied) 58 dBA Power: pluggable via solenoid valve plug type A Alarm relay: pluggable via solenoid valve plug type B mA: when purchasing the mA option, pluggable via Phoenix circular connector 1681101 One mA output per channel possible (no shielding required)...

Open the catalog to page 3
Peltier Gas Cooler Series ECP® - 4

Cooling Capacity ECP1000C Cooling capacity with physical capacity limitation due to different heat exchanger materials GLASS PVDF Outside the specified ambient temperature Outside the specified ambient temperature GLASS PVDF ECP3000C Cooling capacity with physical capacity limitation due to different heat exchanger materials Outside the specified ambient temperature GLASS PVDF ECP2000C Cooling capacity with physical capacity limitation due to different heat exchanger materials Maximum Inlet Dew Point ECP1000C with glass heat exchanger ECP2000C with glass heat exchanger Water vapor inlet dew...