Gas Sample Probe Series SP® - Version SP2100-H
2Pages

{{requestButtons}}

Catalog excerpts

Gas Sample Probe Series SP® - Version SP2100-H - 1

Embracing Challenge SP2100-H Special Features ■ Sampling of dust-loaded process gases ■ Small volume, fast response time ■ Self-regulating electrical heating ■ Alarm contact for low temperature ■ In-situ probe tube 1 m [3.28 ft] long ■ Easy mounting and maintenance Application The patented M&C gas sample probe version SP2100-H is used for continuous gas sampling. Due to the compact design, only a small amount of space is required for installation. The gas sampling probe needs to be installed in a weather-protected place. Description The design of the M&C probe version SP2100-H is geared towards simple mounting, safe operation and problem-free maintenance. The filter element can be replaced without tools and without dismantling the sample line. During the filter change, the filter holder is completely removed from the filter chamber. Easy inspection of the sealing elements, straightforward cleaning of the filter chamber and the possibility of pushing-through the sample tube without removing the probe are just a few of the many advantages offered by the M&C probes. The large-area ceramic depth filter element with 2 qm filter porosity is located in a heated filter chamber made of stainless steel. The compact design and the heat insulation on all sides guarantee optimum heat distribution and safe operation without temperatures falling below the dew point in the filter or probe flange area. The gas sampling probe is heated up to +180 °C by special self-regulating heating elements. The mains voltage ranges from 110 V to 240 V without any necessary switching. An external temperature controller or temperature limitation is not required. A separate thermal switch (< 160 °C, NO) is provided for low temperature monitoring. The electrical connections are located in a terminal box. The scope of delivery includes a 1 m long stainless steel sample tube which is screwed into the mounting flange. The max. sample temperature for this is 600 °C [1112 °F]. The heated double-jacket extraction tubes SP30-H or SP35-H are used for long and cold assembly stubs or when the dew point in the process chamber is underrun. To meet specific sampling requirements, you will find additional sampling tubes and prefilters in the extensive range of M&C probe accessories. Technical specifications and illustrations are without obligation, subject to modifications. 01.19 - 1.00.01 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-

Open the catalog to page 1
Gas Sample Probe Series SP® - Version SP2100-H - 2

Technical Data Probe series SP® 10S9005 Calibration flange, DN 65 PN 6 with 1/8" NPT connection including flange gasket and screw set Standard, other versions on request. AP pressure loss with new filter element S-2K150 7 1 1 20 35 mbar T90 time - without sample tube/pre-filter - 6.0 3.5 1.0 < 0.5 sec M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany Technical specifications and illustrations are without info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 obligation, subject to modifications. 01.19 - 1.00.01

Open the catalog to page 2

All M&C TechGroup Germany GmbH catalogs and technical brochures

  1. EC-30/FD

    3 Pages