1. Catalogs
  2. M&C TechGroup Germany GmbH
  3. Electrically heated valves series V3/2-H, MV3/2-H
video corpo

Electrically heated valves series V3/2-H, MV3/2-H

Electrically heated valves series V3/2-H, MV3/2-H

Electrically heated valves series V3/2-H, MV3/2-H

Product catalog summary
Overview: The document provides technical specifications and features of electrically heated valves from M&C TechGroup, specifically the V3/2-H and MV3/2-H series. These valves are designed for use in analysis techniques where maintaining temperatures above the sample gas dew point is critical.
Specifications: The valves are electrically heated up to 180°C and include an integrated thermostat. They are designed to prevent cold bridges and are easy to maintain. The V3/2-H/PE version includes position identification.
Applications: These valves are used for switching or cutting off sample and test gases, ensuring temperatures remain above the dew point to avoid condensation.
Design and Features: The valves are mounted on a plate, insulated, and equipped with a high-capacity heating element. The temperature is adjustable via an integrated thermostat, with a high-temperature limiter and low-temperature alarm. The enclosure includes a bushing for a dial thermometer and quick-acting closures.
Technical Data: The valves operate at a maximum pressure of 30 bar and a sample gas temperature of up to 180°C. They are suitable for ambient temperatures between -25°C and +60°C and storage temperatures up to +80°C. The power supply for solenoid valves is 24V DC, and the main power supply is 230V 50Hz, with an optional 115V 60Hz.
Materials and Construction: Sample contacting parts are made from stainless steel 316Ti and PTFE, with options for FFKM and FPM. The valves are designed for wall mounting and have a degree of protection rated at IP 54.
Dimensions and Weight: The dimensions are 350 x 320 x 150 mm for the V3/2-H and 350 x 320 x 135 mm for the MV3/2-H, with weights of 7.5 kg and 8 kg, respectively.
See more

Catalog excerpts

Electrically heated valves series V3/2-H, MV3/2-H-1

Embracing Challenge Special Features ■ Electrically heated up to max. 180 °C ■ Integrated thermostat ■ Status contact output ■ Sure connection technique ■ No cold bridges ■ Easy to maintain ■ Option ball valve with position identification [ IVteC®] Electrically heated valves series V3/2-H, MV3/2-H Version V3/2-H /PE, 3/2-way ball valve, electrically heated up to 180 °C, Version MV3/2-H, 3/2-way solenoid valve, electrically heated up to 180 °C Application In analysis technique, often temperatures must be kept above the sample gas dew point. Therefore, it is absolutely necessary to avoid cold bridges. In order to ensure this, the temperature regulated M&C three-way valves V3/2-H and MV3/2 H are used for the cut-off or switching-over of sample gases and test gases up to an operating temperature of 180 °C. Description The M&C electrically heated valves are fixed on a mounting plate, decoupled from heat and covered with an insulated enclosure. The heater consists of a heating element with high capacity. The temperature is adjustable on the integrated thermostat up to 180 °C with high temperature limiter and low temperature alarm. The heat insulated enclosure with a bushing for the dial thermometer is equipped with quick acting bentlever closures. The connection box with integrated thermostat is installed outside the enclosure on the mounting plate. Version V3/2-H/PE has got an additional connecting box for the contact output of the position identification. The power supply for the solenoid valves version MV3/2-H is 24V DC and the additional connecting box is installed on the mounting plate. In order to prevent cold bridges, the connecting fittings are heated by means of thermal conducting jaws. The electrically heated sample lines type 3/4/5-N/M/H - see data sheet 3.1 - are fixed with mounting brackets. Technical specifications and illustrations are without obligation, subject to modifications. 03.96/11.06 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany [email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-

 Open the catalog to page 1
Electrically heated valves series V3/2-H, MV3/2-H-2

Dimensions Electrically heated 3/2-way ball valve, version V3/2-H Alarm contact min. temperature Power in Electrically heated 3/2-way ball valve with position identification, version V3/2-H/PE ø 6,5 left right Contact output position switch Terminals Indicator 50-250° C Alarm contact min. temperature Power in Electrically heated 3/2-way solenoid valve, version MV3/2-H ø 6,5 Terminals solenoid valve 24V DC 15W currentless open from P2 to A P2 Terminals Indicator 50-250°C Alarm contact min. temperature Power in M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany [email protected]...

 Open the catalog to page 2
Electrically heated valves series V3/2-H, MV3/2-H-3

Part-No. Position identification Nominal width / Cv-value Operating pressure Sample gas temperature Ambient temperature Storage temperature Gas connections Temperature controller Operating temperature Dial thermometer Low temperature alarm contact Position identification Power supply solenoid valves Power supply Electrical connections Degree of protection / Electrical standard Dimensions Weight Stacknant volume Materials of sample contacting parts Mounting max. +180 °C -25 to +60 °C -25 to +80 °C tube connectors 06 mm, optional 01/4" type Swagelok capillary thermostat with high temperature limiter...

 Open the catalog to page 3