Overview: The document provides detailed information on the electrically heated sample lines Type 3/4-N/M-S by M&C TechGroup Germany GmbH, designed for use in gas analysis systems. These lines are used to prevent errors and provide frost protection during the transport of sample gas.
Specifications:
  • Temperature Ranges: Two options available - N=100°C and M=200°C.
  • Tube Types: Type 3 with non-interchangeable PTFE tube and Type 4 with interchangeable PTFE tube.
  • Tube Dimensions: Available in DN 4/6 mm or DN 6/8 mm.
  • Operating Temperature: Maximum of +100°C for Type N and +200°C for Type M.
  • Power Consumption: 100 W/m for both DN 4/6 and DN 6/8.
  • Pressure Limits: Type 3 supports up to 5 bar g, while Type 4 supports up to 3 bar g.
  • Ambient Temperature: Ranges from -20°C to +60°C.
  • Electrical Connections: Includes a 1.5 m cable for power and PT100-sensor connection, with a standard power supply of 230V AC.
  • Sample Line Length: Maximum length of 30 meters.
Construction: The sample line consists of a medium tube, heat conductor, high-performance heating, and two layers of thermal insulation, covered by a nylon plaiting. The ends are finished with heat-resistant silicone materials, ensuring complete heating.
Applications: Suitable for stationary, inside, and outside mounting with a minimum bending radius of 400 mm.
Options and Customization: Various inlet and end connection styles are available, including types D/Z and C/Y. The sample lines can be customized for different power requirements (115VAC instead of 230VAC) and other specifications upon request.
Ordering Information: Customers need to specify line type, temperature range, line length, tube dimension, and connection types when placing an order.
See more

Catalog excerpts

Electrically Heated Sample Lines Type 3/4-N/M-S for permanent installation-1

Embracing Challenge Type 4-N(M) 4/6 C/Y Special Features ■ Regulation with external temperature controller ■ Completely assembled ■ PTFE-tube non interchangeable, Type 3/ ■ PTFE-tube interchangeable, Type 4/ ■ Tube 4/6 or 6/8 mm, DN.. ■ 2 temperature ranges, N=100°C, M=200°C [ IVteC®] Electrically Heated Sample Lines Type 3/4-N/M-S for permanent installation Type 3 with PTFE tube non interchangeable Type 4 with PTFE tube interchangeable Application The electrically heated M&C-sample lines series 3/4/-N/M-S may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point). Description The electrically heated M&C-sample lines 3/4-N/M-S are supplied according to clients requirements completely fabricated in the factory with connections and ends to a fixed length. Several options can be supplied: Two different temperature versions (N-100 °C/ M-200 °C), two tube versions (3/4) with either DN 4/6 or DN 6/8 mm each as well as inlet and end connections. The construction of the sample line consists of a medium tube, a heat conductor and the axial taped high performance heating followed by a further two layers of thermal insulation. The outer cover is a nylon plaiting. The ends of the sample line are finished with heat resistant Silicone materials, and the entire construction ensures that the complete sample line is properly heated, including the ends. The sample line is equipped with a PT100 for temperature detection. Technical specifications and illustrations are without obligation, subject to modifications. 10.04/06.06 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany [email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

 Open the catalog to page 1
Electrically Heated Sample Lines Type 3/4-N/M-S for permanent installation-2

Type 3 with PTFE tube non interchangeable Type 4 with PTFE tube interchangeable Sample line length „LL Sample lines Type 3/4-N/M Operating temperature, max. Power consumption at DN 4/6 Power consumption at DN 6/8 Pressure, max. Ambient temperature, max. Tube DN Sample line inlet and end connections Electrical connections Power supply PT100-Sensor position Weight Sample line max. length Sample line inlet and outlet seal connections Thermal insulation Outer cover Application fields / smallest bending radius 100 W/m 100 W/m Type 3 = 5 bar g, Type 4 = 3 bar g -20 °C up to + 60 °C optional 4/6 or...

 Open the catalog to page 2
Electrically Heated Sample Lines Type 3/4-N/M-S for permanent installation-3

Description Sample lines per meter Electrically heated sample line type 3 with non interchangeable PTFE tube, max. 100 °C Electrically heated sample line type 3 with non interchangeable PTFE tube, max. 200 °C Electrically heated sample line type 3 with non interchangeable PTFE tube, max. 100 °C Electrically heated sample line type 3 with non interchangeable PTFE tube, max. 200 °C Electrically heated sample line type 4 with interchangeable PTFE tube, max. 100 °C Electrically heated sample line type 4 with interchangeable PTFE tube, max. 200 °C Electrically heated sample line type 4 with interchangeable...

 Open the catalog to page 3

All M&C TechGroup Germany GmbH catalogs and technical brochures

  1. EC-30/FD

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.