Overview: The document provides detailed specifications and features of M&C TechGroup's explosion-proof electrically heated sample lines, designed for use in gas analysis systems. These lines are suitable for installation in explosion zones 1, 2, 21, and 22, and are available in different configurations to meet various application needs.
Specifications: The sample lines are available in three types: Type 3 with non-interchangeable PTFE tube, Type 4 with interchangeable PTFE tube, and Type 5 with non-interchangeable stainless steel tube. They come in two temperature ranges, N (100°C) and M (200°C), and support hose/tube diameters of 4/6, 6/8, or 8/10 mm. The lines are designed to operate at a maximum ambient temperature of 65°C and are powered by a 230V AC supply.
Construction: The sample lines feature a robust construction with a medium tube/pipe inside a thermally conductive stainless steel mesh, which provides protection and support. The heat conductor is coiled around this mesh, followed by two layers of thermal insulation, and an outer cover made of polyamide. The ends are finished with heat-resistant silicone materials.
Applications: These sample lines are used to prevent errors and provide frost protection during the transport of sample gas from the sample point to the gas conditioning system or directly to a heated analyzer. They are equipped with two Ex-PT100 sensors for temperature detection, ensuring safe operation in explosive environments.
Technical Data: The sample lines have a power consumption of 100 W/m and can handle pressures up to 5 bar for Type 3, 3 bar for Type 4, and 100 bar for Type 5. The maximum sample line length is 30 meters for 230V and 13 meters for 115V configurations.
Options and Accessories: The document lists various inlet and end connection parts, as well as options for different power supplies and additional heating circuits. An explosion-proof temperature controller is available, which includes a temperature limiter and external control panel, suitable for Ex-Zone 1 and 21.
Ordering Information: Customers are advised to specify the line type, temperature range, line length, tube dimension, inlet and end connection parts, and temperature controller when placing an order.
See more

Catalog excerpts

Controlled explosion proof electrically heated sample lines type 3/4/5-N/M Ex-1

Type 4-N(M) 4/6 EX C, Y Special Features ■ Approval according to ATEX for mounting in explosion zone 1, 2, 21 and 22 ■ Regulation with external temperature controller ■ Completely assembled ■ PTFE-tube non interchangeable Type 3/ ■ PTFE-tube interchangeable Type 4/ ■ Stainless steel tube non interchangeable Type 5/ ■ Hose/tube 0 4/6, 6/8 or 8/10 mm DN.. ■ 2 temperature ranges N=100°C, M=200°C Controlled explosion proof ^5^ electrically heated sample lines type 3/4/5-N/M Ex Type 3 with PTFE tube non interchangeable Type 4 with PTFE tube interchangeable Type 5 with stainless steel tube Application The explosion proof electrically heated M&C-sample lines series 3/4/5-N/M EX may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point). Description The explosion proof electrically heated M&C-sample lines 3/4/5-N/M EX are supplied according to clients requirements completely fabricated in the factory with connections and ends to a fixed length. Several options can be supplied: 2 different temperature versions (N-100 °C/ M-200 °C ), EX T3 3 tube/pipe versions (3/4/5) with either N 4/6, 6/8 or DN 8/10 mm each as well as 3 inlet connections (C/D/E) and 3 end connections (W/Y/Z). The robust construction of the sample line consists of a medium tube/pipe inside a thermally conductive stainless steel mesh which acts also as protection and support. The heat conductor is also coiled around the stainless steel protective mesh followed by a further two (2) layers of thermal insulation. The outer cover is a corrugated tube out of polyamide. The ends of the sample line are finished with heat resistant Silicone materials, and the entire construction ensures that the complete sample line is properly heated, including the ends. The explosion proof sample lines are equipped with two Ex-PT100 intrinsically safe 2GD according to ATEX for temperature detection. Technical specifications and illustrations are without obligation, subject to modifications. 01.11 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany [email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

 Open the catalog to page 1
Controlled explosion proof electrically heated sample lines type 3/4/5-N/M Ex-2

Possible Connections and Styles of the Heated Sample Lines Sample line Inlet connection style Type 3 with PTFE tube non interchangeable Technical specifications and illustrations are without obligation, subject to modifications. 01.11 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany [email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-

 Open the catalog to page 2
Controlled explosion proof electrically heated sample lines type 3/4/5-N/M Ex-3

Temperature-limiter as spare for combination Item No. 03B8000 Explosion-proofed version for Ex-Zone 1 and 21 protection class according to 03B8020 ATEX: II 2 GD E Ex em IIC T4 IP65 T100, Measure- and control range: -40 up to 300°C capacity: 16A, Power: 230V/50Hz. Ambient temperature: -32 up to 65°C External control panel as spare for combination Item No. 03B8000 Explosion-proofed version for Ex-Zone 1 and 21 protection class according to 03B8030 ATEX: II 2 GD E Ex ib IIC T4 IP65 T100 Other executions on request. Technical specifications and illustrations are without obligation, subject to modifications....

 Open the catalog to page 3
Controlled explosion proof electrically heated sample lines type 3/4/5-N/M Ex-4

Dimensions controlled explosion proof heated sample line Mounting holes for two-part cabinet-bushing for line diameter 62mm Dimensions temperature controller, limiter and control panel Please specify with order: • line type (3/4/5) • line length in meter • 1x inlet connection part (C-E) • temperature range (N/M) • tube dimension DN (4/6, 6/8, 8/10) • 1x end connection part (W-Z) • 1x temperature controller For example: 6x 03B4510 6 m electrically heated sample line, 4M4/6 EX, max. 200 °C with interchangeable PTFE tube DN 4/6, 1x 03B1520 inlet connection part C/EX, 1x 03B2510 end connection part...

 Open the catalog to page 4

All M&C TechGroup Germany GmbH catalogs and technical brochures

  1. EC-30/FD

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.