Mobile service for for coolant- and lubricant systems
4Pages

{{requestButtons}}

Catalog excerpts

Mobile service for for coolant- and lubricant systems - 2

Filter unit Control block The return-line filter TEF 952 is mounted directly on the top of the tank and connected to the pressure line. The used filter element Interporvlies VGӔ is charact- erised by deep filtration at low pressure difference and highest dirt holding capacity. Following to the suction of the fluid by the membrane pump the control block may route to the filter unit, to the exit line or to the low pressure cleaning gun. Additionally there is an extension port for retrofitting components. > Air pressure operated membrane pump Oil separation mechanism This type of self-priming...

Open the catalog to page 2
Mobile service for for coolant- and lubricant systems - 3

Net weight appr. 550 lbs Dimensions 59 x 37 x 52 in. Operation by air pressure Reservoir volume 160 gallons Extraction of other fluids Yes Extraction of chips max. grain size 0.24 in.pilot filter suggested Separation of other fluids separation tank Solid particle separation filter fineness from 1 m to 25 յm Cleaning of the machine hand cleaning gun up to 87 PSI >