Overview: The document provides technical specifications and guidelines for Medium Intensity Obstruction Lights (MIOL) used in hazardous areas where obstacles are large and the surrounding ground height exceeds 45 meters. These lights comply with ICAO, FAA, and ATEX standards.
Specifications: The MIOLs are categorized into Type A Ex, B Ex, and C Ex. Type A Ex is white flashing, Type B Ex is red flashing, and Type C Ex is red steady burning. The lights are designed for efficient, lightweight, and compact obstacle signaling.
Features: The lights are based on LED technology, offering a stabilized light output of 2,000 cd. They have a horizontal beam radiation of 360° and a vertical beam spread of 4°. The lights are protected by a borosilicate glass cover and have an IP66 degree of protection. They operate in temperatures ranging from -52°C to +60°C.
Certifications: The MIOLs are certified under ATEX, IECEx, and have CE marking. They comply with ICAO Aerodromes Annex 14 and FAA standards.
Applications: These lights are suitable for use on stacks, chimneys, tower cranes, offshore platforms, and chemical and petrochemical plants.
Electrical Features: The MIOL-B Ex has an average power consumption of 9W at 20 FPM, 12W at 40 FPM, and 15W at 60 FPM. The MIOL-C Ex consumes 54W for steady burning. The lights include features like alarm/remote status control and lightning protection.
Options: The lights offer options such as twin version with two galvanically separated circuits, infrared version, and GPS synchronization. They also provide fault alarms and automatic changeover from normal to backup light.
See more

Catalog excerpts

L864-LXS-Ex-1

MEDIUM INTENSITY MEDIUM INTENSITY OBSTRUCTION LIGHT PAievTed EwNithTthEeDconftorribBuidtios n ch ll Patent a e Lombardia_Ca asure F" n io g _ n Me of Re Innovatio & h c r a "Rese According to ICAO - Annex 14 Medium Intensity Obstruction Lights - Type A Ex, B Ex or C Ex - have to be used where the obstacle is particularly large and the height of the surrounding ground is more than 45m in hazardous areas. Medium Intensity Obstacle Lights Type A Ex and C Ex have to be used alone, whereas Medium Intensity Obstacle Lights, Type B Ex, should be used either alone or in combination with Low Intensity Obstacle Lights, Type B Ex. The Medium Intensity Obstruction Lights Type A Ex is white flashing. The Medium Intensity Obstruction Lights Type B Ex is red flashing. The Medium Intensity Obstruction Lights Type C Ex is red steady burning.

 Open the catalog to page 1
L864-LXS-Ex-2

MEDIUM INTENSITY MIOL-B Ex / MIOL-C Ex Borosilicate glass cover protection Twilight sensor* Stabilised light output: 2.000cd Based on LED technology Red flashing light (MIOL-B) Red steady burning light (MIOL-C) Standard circuits or TWIN* Infrared version* RAL 7035 painted aluminium body lamp Medium Intensity Obstruction Light is according to ICAO (Medium Intensity – Type B or C), FAA (Type L-864) and ATEX certified. This beacon is the ideal solution for an efficient, lightweight and compact obstacle signalling. MIOL-B Ex is emits a red flashing light, while MIOL-C Ex emits red steady burning...

 Open the catalog to page 2
L864-LXS-Ex-3

MEDIUM INTENSITY MIOL-B Ex and MIOL-C Ex TECHNICAL SPECIFICATIONS OPTICAL FEATURES • • • • • • • • • Based on LED technology RED light 2.000cd Cd emission @ -0,5° and +4° Horizontal beam radiation: 360° Vertical beam spread: 4° PMMA lens (PMMA) Light output alignment device ATEX execution: Ex II 2GD Ex de IIC T4 Gb Ex tb IIIC T135°C Db IP66 IECEx execution: Ex db e IIC T4 Gb Ex tb IIIC T135°C Db IP66 INFRARED VERSION OPTIONS • Twin version: two galvanically separated circuits in the same fixure Fault alarm Automatic changeover from normal to backup light Infrared version MECHANICAL FEATURES •...

 Open the catalog to page 3
L864-LXS-Ex-4

MEDIUM INTENSITY MIOL-B Ex and MIOL-C Ex TECHNICAL SPECIFICATIONS 2600 2400 2200 2000 1800 1600 1400 1200 L864-LXS-Ex-B/C average emission level at 90°C ambient temp. ICAO ANNEX 14 medium intensity type B/C Min. Required Intensity ICAO ANNEX 14 medium intensity type B/C Max. Required Intensity