Powerful battery series Wireless power for professional use in industry Lutz Battery Series B1 | B2 | B3 safety is our concern
Open the catalog to page 1Lutz Battery Series B1 | B2 | B3 Versatility in series With the development of the battery pumps B1 Battery and B2 Battery, Lutz reached a new level of mobility, battery performance, weight, service life, pump capacity and ergonomics. Many possible combinations allow a wide range of liquids to be pumped from different containers. With the latest development of the Battery series, Lutz presents a highperformance motor. The B3 Battery achieves delivery rates comparable to its grid-connected counterpart - while remaining mobile and flexible. Features/Benefits: BLDC motor with high efficiency of...
Open the catalog to page 2* See operating instructions for more information ** In combination with a B70V-SR eccentric screw pump, up to 700 mPas with a drum pump ’The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C. The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. Viscosity determined...
Open the catalog to page 34 Lutz Battery Series B1 | B2 | B3
Open the catalog to page 46 Lutz Battery Series B1 | B2 | B3
Open the catalog to page 6Lutz Battery Series B1 | B2 | B3 Drum Pump Sets Lutz offers you individual pump sets with pre-assembly for quick use. Optionally, the pumps can be combined with a flow meter. Take advantage of our know-how - we configure, you decide! ideally matched to the liquid being pumped ready for operation in just a few steps quick to use, thus saving time Motors three battery motors are available Nozzles for safe filling of liquids Drum adapter for securely fasten the pump in the drum opening Hoses resistant to liquid and with practical 2 m hose Pump tubes resistant to liquids, in different lengths, for...
Open the catalog to page 810 Lutz Battery Series B1 | B2 | B3 For thin-bodied fluids such as battery acid, ammonia water, photographic developer/-fixer, glycols, phosphoric acid, hydrochloric acid and hydrogen peroxide. For removing small guantities from hobbocks, canisters and drums. 70 watts, internally ventilated, IP24 1 The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20°C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The flow rate achievable in use is lower and depends on the individual...
Open the catalog to page 10Lutz Battery Series B1 | B2 | B3 11 For thin-bodied fluidssuch as battery acid, ammonia water, photographic developer/-fixer, glycols, phosphoric acid, hydrochloric acid and hydrogen peroxide. For removing small guantities from hobbocks, canisters and drums.■ Motor B2 Battery260 watts, internally ventilated, IP24 Technical data Maximum liquid temperature 50 °C The use of the nozzle reduces the flow rate to approx. values (data in bracket). The use of the flow meter reduces the viscosity to approx. values (data in bracket). 1 The maximum flow rate is a value determined by means of a test bench...
Open the catalog to page 1112 Lutz Battery Series B1 | B2 | B3 For concentrated acids and alkalis such as chloric acid, chromic acid, sulphuric acid, nitric acid, hydrofluoric acid and sodium hypochlorite. For removing small quantities from hobbocks, canisters and drums. 260 watts, internally ventilated, IP24 Technical data 1 The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20°C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The flow rate achievable in use is lower and depends on the individual...
Open the catalog to page 12Lutz Battery Series B1 | B2 | B3 13 Pump Set B2 Battery (stainless steel) For thin-bodied fluids such as oil-based lubricants, cold cleaners and plasticisers. For removing small quantities from hobbocks, canisters and drums. 260 watts, internally ventilated, IP24 Technical data Density 1.6 kg/dm3 Maximum liquid temperature 90 °C The use of the nozzle reduces the flow rate to approx. values (data in brackets). Version with universal chemical hose and stainless steel nozzle Version with mit PVC hose and Lutz nozzle 1 The maximum flow rate is a value determined by means of a test bench and measured...
Open the catalog to page 1314 Lutz Battery Series B1 | B2 | B3 1 The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20°C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The flow rate achievable in use is lower and depends on the individual application, the media properties and the configuration of the pump. The max. delivery head is also dependent on the pump design, motor and medium. Viscosity determined with oil. Will be delivered without battery and battery charger.
Open the catalog to page 14Lutz Battery Series B1 | B2 | B3 15 1 The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20°C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The flow rate achievable in use is lower and depends on the individual application, the media properties and the configuration of the pump. The max. delivery head is also dependent on the pump design, motor and medium. Viscosity determined with oil. Will be delivered without battery and battery charger.
Open the catalog to page 1516 Lutz Battery Series B1 | B2 | B3 For light viscous mineral oils such as diesel, fuel oil, hydraulic oil,machine oil and engine oil. For removing large quantities from canisters, drums and containers. 320 watts, internally ventilated, IP24 1 The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20°C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The flow rate achievable in use is lower and depends on the individual application, the media properties and the configuration...