T-Gauge® HXC51yn

T-Gauge® HXC51yn

T-Gauge® HXC51yn

Product catalog summary
Overview
The HXC51yn Online Sensor Head with Virtual Reference Surface (VRS) enhances the standard HXC50yn sensor head by enabling non-contact, calibrationless measurements of thickness, basis weight, and density. It maintains the open separation between the sensor and the product, ensuring efficient reflection measurement of multi-layer surfaces.
Specifications
  • Polarization Extinction Ratio: > 20:1 (Horizontal)
  • Available Lens Focal Lengths: 25, 75, 150 mm, collinear
  • Beam Diameter: 38 mm
  • Mounting Hardware: 1/4 - 20 threaded holes
  • Operating Temperature Range: 0 - 50 °C, 20 - 90% RH non-condensing
  • Size: 128 x 66 x 178 mm
  • Weight: 1.8 kg with VRS
Applications
  • Industrial process control: roofing, foam density, paint thickness, plastic extrusion, asphalt shingles
  • Nondestructive materials inspection: aircraft, packaged goods, radome, spacecraft, pipeline repairs
  • Converting applications: paper coating, multilayer films, tires
Key Features and Benefits
  • Full transceiver functionality with collinear design
  • Low-cost plastic lens and hardened case for industrial environments
  • Single high-flex umbilical for continuous scanning
  • Supports VRS functionality, eliminating the need for separate transmitter and receiver
  • Improves product quality by optimizing production and is tolerant to dirt and dust
Compliance and Certification
The T-Ray 5000 intelligent TCU is certified by Underwriters Laboratories, has the CE mark, complies with FDA CDRH laser safety regulations, and meets FCC part 18 regulations.
Included Components
  • HDPE Lens (1, 3, or 6 inches)
  • Terahertz Controller
  • Umbilical (5, 10, or 30 meters)
  • T-Ray® Basic and T-Gauge® Software
See more

Catalog excerpts

T-Gauge® HXC51yn-1

Online Sensor Head with VRST-Gauge® HXC51yn HXC51yn The HXC51yn1 Online Sensor Head adds functionality to the standard online sensor head (HXC50yn) with a virtual reference surface (VRS). Reflection measurement of thickness, multi-layer thickness, basis weight, and density are easily acquired. The VRS enables noncontact, calibrationless caliper thickness measurement as well as basis weight and density without reducing the open separation between the sensor and the product. The transmitter and receiver are securely mounted inside the sealed metal housing. The umbilical for the transceiver, containing the electrical and optical connections, is constructed with high flex rated electrical cable to allow for continuous scanning. When connected to a T-Ray® 5000 Control Unit, the HXC51yn will provide excellent waveform response, capable of providing detailed reflection measurement of layered surfaces. • y = 4 for 75mm lens and 5 for 150mm lens, n = 1 for a Type 1 (HP) transmitter and 2 for a Type 2 (GP) transmitter. • Industrial process control: commercial roofing; foam density; paint thickness; plastic extrusion; asphalt shingles • Nondestructive materials inspection: aircraft; packaged goods; radome inspection; spacecraft; pipeline repairs Full transceiver functionality Collinear design Low cost plastic lens Hardened case for industrial environment Use to measure layer thickness • Use to produce scanned images • Single high flex umbilical • Variety of focal lengths available Capable of being cleaned Supports VRS functionality • No need for separate transmitter and receiver • Simple orientation to target Inexpensive to replace if damaged Extended lifetime Replace multiple sensors Compatible with various motion options Long umbilical life in scanner or robot Improve product quality by optimizing production Tolerant to dirt and dust in the factory Increases product gap for density measurements Converting applications: paper coating; multilayer films; tire

 Open the catalog to page 1
T-Gauge® HXC51yn-2

Online Sensor Head with VRS T-Gauge® HXC51yn ORDERING INFORMATION Included Typical Configuration • Terahertz Controller • T-Ray® Basic and T-Gauge® Software Industry Leading Regulatory Compliance The T-Ray 5000 intelligent TCU has been certified by Underwriters Laboratories has received the CE mark, is fully compliant with FDA CDRH laser safety regulations, and has been tested to meet FCC part 18 regulations.

 Open the catalog to page 2

All Luna Optoelectronics catalogs and technical brochures

  1. HSC50yn

    2  Pages

  2. T-Ray® 5000

    2  Pages

  3. os3100

    2  Pages

  4. 3DViz

    2  Pages

  5. PSG 2000

    3  Pages

  6. LPD 100

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.