measurement of d.c. voltage. three-colour led display (5 digits, 14 mm high). digital output RS-485 - Modbus RTU protocol. two alarm outputs of oc type. programmable parameters through rs-485 interface using the free econ software: – two alarms of oc type operating in 6 working modes, – display colour programmable in three intervals, – thresholds of displayed overflows, – highlight of the unit, – measurement averaging time. • conversion of indications based on individual characteristics. • power supply: 85 ... 253 V ac / dc or 20 ... 40 V ac / dc. • ip65 housing protection degree. - digital panel meter witH rs-485 eXample of application Measurement of dC current and volatge of solar installation and remote monitoring of parameters. global monitoring solar panel galVanic isolation Supply
Open the catalog to page 1LUMEL EVERYTHING COUNTS N2QHPLUS - DiGiTAL PANEL METER with RS-485technical dataiNPUTS Input type Output type Alarm outputs features • 2 alarm outputs of oc type Transmission protocol modbus RTU EXTERNAL FEATURES Readout field panel cut-out: 92+“ x 45+“ mm from terminal side: ip 10 Three-colour display (changes of colour depend on the displayed value): red, green, orange. RATED OPERATiNG CONDiTiONS 85...253 V a.c. (45...65 Hz) or d.c., 20...40 V a.c. (45...65 Hz) / 20..60 V d.c. Temperature relative humidity operating position SAFETY AND COMPATiBiLiTY REQUiREMENTS Electromagnetic compatibility...