1. Catalogs
  2. LÜTZE
  3. Cable Entry Systems CABLEFIX ONE and CABLEfix X

Cable Entry Systems CABLEFIX ONE and CABLEfix X

Cable Entry Systems CABLEFIX ONE and CABLEfix  X
1 / 73 PagesView full catalog

Cable Entry Systems CABLEFIX ONE and CABLEfix X

Product catalog summary
Overview
LÜTZE is a prominent company in the automation industry, offering electronic and electrotechnical components, system solutions for automation, and high-tech solutions for rail engineering. Their products include high flexing cables, energy-efficient wiring systems, and Industry 4.0 solutions.
Business Management
LÜTZE focuses on sustainable business practices, prioritizing long-term success and environmental responsibility. Their products are designed to save energy and resources.
LCOS Current Monitoring System
The LCOS system is used for load monitoring in low-voltage networks, suitable for industries like steel, shipbuilding, and mining. It offers reliable current control with optional field bus connection.
Power Supplies
  • Structure: Includes unregulated and regulated designs with safety features like galvanic isolation and protection classes.
  • Input Voltage: Supports wide-range input and manual range selection.
  • Protection: Features overload and short-circuit protection, thermal protection, and derating at high temperatures.
Specifications and Parameters
Power supplies maintain stable output voltage without a minimum load, with overvoltage protection and power failure buffering.
Line Cross-section and Protection
Includes input-side safety fuses and output-side electronic protection for overloads, ensuring system operability.
Power Factor Correction (PFC)
European standards limit harmonic emissions. Passive and active PFC methods are used to reduce harmonics.
Applications
Parallel connection of power supplies increases output capacity, with redundancy ensuring system continuity.
Protection of DC 24V Circuits
Challenges in selective protection are addressed with automatic circuit-breakers.
Ethernet Connectivity
Ethernet is crucial in industrial networks, with LÜTZE providing solutions for robust network infrastructures.
Switch Functionality
Switches connect LANs, process MAC addresses, and enhance network performance by enabling simultaneous data transmission.
Switched Ethernet in Industrial Applications
Networks are segmented to maintain bandwidth and ensure timely data transmission.
OSI Model and Protocols
Details the OSI model layers and protocols, emphasizing network topology and load distribution.
Cable Types and Specifications
Ethernet installations use symmetric or fiber-optic cables, with details on shielding and cable categories.
Installation and Wiring Tips
Guidelines for installing copper cables, emphasizing compliance with standards.
Data Rate and Transmission Medium Overview
Overview of Ethernet data rates and transmission media, including IEEE standards.
Ethernet Standards and Specifications
Details various Ethernet standards like 1000BaseSX, 1000BaseLX, and 10GBase standards.
RJ45 Pin Assignment
Details pin assignments for Ethernet standards, highlighting bidirectional nature of 1000BaseT.
Power over Ethernet (PoE)
Standardized as 802.3af, PoE uses CAT5 infrastructure, offering cost savings.
LCOS – LÜTZE Communication System
An open, modular system supporting IIoT/Industry 4.0 applications, with features like tool-free plug-in modules.
Product Overview
Includes power supplies, Ethernet connectivity options, and current control systems.
Technical Specifications
Details specifications for LCOS power supplies, including voltage, current ratings, and protection features.
Specifications
  • Rated Voltage: DC 24 V
  • Operation Voltage Range: DC 20.4–28.8 V
  • Rated Current: Up to DC 10 A or 16 A
  • Switching Element: MOSFET, with relay options
  • Protection: Reverse voltage protection
Features
  • Fault Messaging: Includes single, collective, and utilization messages
  • Control Input: Set/Reset with pulse requirements
  • Status Display: LED indicators
  • Communication: CANopen bus communication support
General Information
  • Housing Material: PA 6.6
  • Mounting: DIN rail
  • Protection Class: IP20
  • Operating Temperature Range: 0 °C to +55 °C
  • Certifications: cULus, UL 61010, CE
Applications
Suitable for stationary use in weather-protected locations, providing reliable load monitoring.
Specifications
  • MOSFET and Relay: Features galvanic separation and LED status indicators.
  • Load Monitoring: Supports up to DC 16 A with adjustable characteristics.
  • Bus Couplers: Includes PROFINET, EtherCAT, and EtherNet/IP options.
Procedures
  • Installation involves DIN rail mounting and plug-in connections.
  • Temperature ranges and storage conditions are specified.
Standards and Certifications
  • Components comply with standards like EN 61131-2 and EN 61000.
  • Certifications include CE, cULus, and DNV GL.
Recommendations
  • Ensure proper installation and configuration.
  • Utilize appropriate accessories for optimal performance.
Key Data from Tables and Figures
  • Dimensions and weight for installation planning.
  • Pin assignments and connection types for accurate setup.
Specifications
  • Temperature Range: -40 °C to +85 °C
  • Protection Class: IP20
  • Humidity: 5% to 95% without condensation
  • Shock and Vibration Resistance: As per IEC 60068-2-27
Function Carriers
  • Available in 22.5 mm and 35 mm widths.
  • Integrated power bus and data module options.
Power Modules
  • Available in 4-pin configurations.
  • Operating voltage up to 500 V AC/DC.
Data Modules
  • 12-pin configurations available.
  • Operating voltage up to 30 V DC.
Plug-in Terminals
  • Available in 12-pin and 8-pin configurations.
  • Operating voltage up to 300 V AC/DC.
Certifications and Standards
Components are certified under UL, DNV GL, and comply with standards like EN 60947-1.
Availability
Products are marked as available from stock, with a lead time, or on request.
General Specifications
Outlines ambient conditions for operation and storage, referencing standards like EN 60064-1.
Product Availability
Products are categorized as 'S' for stock, 'A' for available with a lead time, and 'R' for available on request.
Accessories
Lists various accessories with part numbers and descriptions.
Characteristic Curves
Details characteristic curves for LCOS-CC and LCOS-CCI devices.
Temperature Sensor and Service Cable
Details specifications for the PT 100 temperature sensor and service cable.
AirBLOWER Control Unit
Provides technical data for the AirBLOWER fan and control unit.
Installation Instructions
Provides detailed steps for installing LCOS-CC and LCOS-CCI systems.
Additional Information
Includes links to online resources and a part number index.
Contact Information
Provides contact details for Lütze offices worldwide.
Solutions Overview
Concludes with an overview of Lütze's solutions in various sectors.
See more

Catalog excerpts

Cable Entry Systems CABLEFIX ONE and CABLEfix  X-1

Power Supplies Industrial Communication Load Monitoring

 Open the catalog to page 1
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-2

Cable Solutions LÜTZE - Efficiency in Automation Connectivity Solutions Cabinet Solutions A tradition in automation for over 60 years, with countless pioneering achievements and patents, the LUETZE INTERNATIONAL Group is today one of the leading companies in the automation industry. LÜTZE supplies very efficient electronic and electrotechnical components, system solutions for automation and high tech for rail engineering. The comprehensive and coordinated supply program ranges from high flexing cables and cable assemblies, to energy efficient AirSTREAM wiring systems for control cabinets through...

 Open the catalog to page 2
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-3

Business Management: Sustainable and forward-looking „The competitiveness of our industry and of its suppliers depends quite substantially on how we succeed in developing practical results. The results that we produce together today, are our competitive advantages in the future.“ Udo LOTZE, Member of the Executive Committee of the Green Carbody Innovation Alliance The future is blue Goods with real value Sustainable enterprise means thinking and planning ahead, understanding and embedding the belief that long lasting success is more important than short-term profit maximisation. This is an attitude...

 Open the catalog to page 3
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-4

LCOS current monitoring system - hard as steel In case of expensive or dangerous system Full control when it is really failures, a low-voltage network (Isolé Terre) important! provides the best solution for load monitoring. This could be very important in the steel, shipbuilding and mining industries, or in hospitals, airports, computer centers or control centers. The ground in these systems is separated galvanically from the active conductors which means that the power supply is not switched off immediRead the entire article about the harsh ately in the event of an error. LÜTZE's curconditions...

 Open the catalog to page 4
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-5

Power Supplies · Basics 2. Safety A power supply has a decisive influence on the availability and operational reliability of electrical systems. The safety of people and equipment is always the priority. Accordingly, power supplies must comply with unified regulations and standards. Consequently, the selection of the right power supply should be just as critically and carefully undertaken as that of the other system components. 1. General structure Regardless of the technology employed, power supplies are devices with an input side and an isolated output side. Galvanic isolation generally refers...

 Open the catalog to page 5
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-6

2.5 SELV SELV according to IEC/EN 60950 is a safety extra low voltage which thanks to its low level and insulation offers better protection against electric shock than higher-tension circuits. Power supplies generating SELV, for example, must be designed to prevent shorting between the primary and secondary windings and their connections. The windings can only be overlaid if double or reinforced insulation is placed between them. This isolation is termed galvanic isolation. Grounding of the secondary side is not required but permitted. The peak value must not exceed 42.4 V in case of AC voltages...

 Open the catalog to page 6
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-7

Power Supplies · Basics up to a degree where safe operation is no longer guaranteed. There are a number of techniques for protecting the power supply against destruction due to overheating. • The maximum output power is reduced, allowing the power supply to cool down. U/I characteristic Lütze power supplies with a U/I characteristic perform current limiting to typically 1.2 times the nominal current at constant output voltage. This current is still available in case of an overload or a short circuit. The voltage is slowly lowered, while the output current may rise further (triangular current...

 Open the catalog to page 7
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-8

Parallel selectivity Based on the self-protection, the output voltage is switched off or reduced in the event of a fault. If multiple loads are carried on one power supply, a voltage drop will occur throughout the entire application. To prevent this, protective devices are installed in the individual lines to the consumers. If a fault occurs, the protective device concerned must trip fast enough so as to disconnect the faulty consumer reliably from the rest of the system and such that the other consumers remain available. 8.4 Connection cross-sections The line cross-sections are selected dependent...

 Open the catalog to page 8
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-9

Reliable protection of DC 24V circuits Intelligent safeguarding of selectivity Primary switching controllers and automatic power units nowadays form the basis of the DC 24V supply level. Due to the operating behaviour of those devices, the specified selective protection of individual circuits, especially in case of overcurrent, is virtually unfeasible. A complete system shutdown is inevitable. Operating behaviour of primary switching controllers Switched-mode power supplies and their components are rated for a specific nominal value and run hot under higher load. To protect against self-destructing,...

 Open the catalog to page 9
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-10

LOCC-Pads* Software for the parameterisation of the LOCC-Box-Net, as well as the analysis and diagnosis of DC 12 / 24 V circuits Displays the operating status, current range / characteristic, the load capacity of the characteristic, as well as the updated current and voltage values. LOCC-Box Ctarakteristk loom [A] 1.0 Displays the parameters of the selected characteristic curve. LOCC-Box Zahler- Indicates the current meter readings of the selected module

 Open the catalog to page 10
Cable Entry Systems CABLEFIX ONE and CABLEfix  X-11

LUTZE Ethernet Connectivity - Solutions from a single source The requirements placed on efficient manufacturing systems are becoming more and more complex. Increased networking between production and management means that more and more automation systems are requiring the use of PC-based controllers and Ethernet communication networks. Ethernet is the name of a widely used, standardised communication infrastructure with various communication media. Together with higher-level communication software, Ethernet is today the basis for a large number of industrial local networks. In contrast to the...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.