The document discusses the challenges of reliable pH measurement in industrial processes and waste streams over extended periods without maintenance. LTH Electronics offers spray wash cleaning adapters for pH electrode systems to reduce maintenance and improve electrode life, particularly where electrode bulbs are prone to coating. These adapters are effective for both in-line and dip applications.
The spray wash fittings feature a full coned spray nozzle mounted under the electrode bulb, applying a cleaning solution at 4 litres per minute and 4 Bar pressure. An 18-litre isolating break tank with a ball valve and a pump in a wall-mounted enclosure can be supplied. The break tank isolates the system from the water supply, complying with local bylaws.
The pump, housed in a polycarbonate enclosure, uses a positive displacement 3-chamber diaphragm system with a check valve to prevent reverse flow and can self-prime up to 2.5 metres. It includes a pressure switch and thermal cut-out for protection. Tubing is ordered separately.
When used with LTH MPD53 pH monitor or HPT63 Advanced pH transmitter, the cleaning cycle can be controlled. Set point relays can be configured as a Clean output, with programmable Clean duration, Recovery time, and Interval period. The system allows for taking the monitor or transmitter offline during cleaning, holding the current output and de-energizing control relays.
Clean duration ranges from 5 seconds to 10 minutes, intervals from 5 minutes to 48 hours, and sensor recovery time from 5 seconds to 10 minutes. Set point relays can delay cleaning if chemical dosing is occurring, prioritizing pH control over cleaning.
Various assemblies are described, each with specific part numbers, descriptions, and requirements for wash solution flow and pressure. Materials include PVC and polypropylene, with fittings and wash tubing included.
These products comply with current European Directives.
Spray Wash CleaningAutomatic pH and Redox Electrode Cleaning Features • Automate electrode cleaning • Reduce maintenance time and costs • Improve Electrode life • In-line and dip options available
Open the catalog to page 1pH measurement of many industrial processes and waste streams can be difficult to measure reliably over extended time periods without some form of maintenance. LTH Electronics can offer spray wash cleaning adapters for their pH electrode systems to reduce maintenance and improve electrode life in applications where a pH or Redox electrode bulb is prone to coating. They provide an effective method of cleaning the electrodes in both in-line and dip applications. The spray wash fittings have a full coned spray nozzle which is mounted under the pH or Redox electrode bulb with a cleaning solution...
Open the catalog to page 2Specification Fittings Maximum Temperature: Maximum Pressure: Wetted Materials: Cleaning Solution: Pump Pump Design: Check Valve: Motor: Voltage: Pressure Switch: Prime: Connectors: Tubing: Pump Enclosure Material: Dimensions: Tank Material: Dimensions: Mains Water Inlet: Outlet: Overflow: LTH Electronics www.lth.co.uk 90 °C For Part No.'s 2117, 2118, 2136, 2137 and 2138 50 °C for Part No.'s 2120, 2134, 2135, 2119 and 2120 3 Bar for Part No.'s 2120, 2134, 2135, 2119 and 2120 Polypropylene, Nylon Tubing For Part No.'s 2117, 2118, 2136, 2137 and 2138 PVC, Polypropylene for Part No.'s 2120, 2134,...
Open the catalog to page 3LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England Telephone: +44 (0)1582 593693 Fax: +44 (0)1582 598036 email: [email protected] web: www.lth.co.uk LTH Electronics Ltd reserves the right to make changes to thte data sheet or the product without notice, as part of our policy of oontinued developments and improvements. All care has been taken to ensure the accuracy of information contained h this data sheet. However we cannot accept responsibility for any errors or damages resulting from errors or inaccuracies of information ccntahed herein.
Open the catalog to page 44 Pages
2 Pages
2 Pages
2 Pages
20 Pages
12 Pages
9 Pages
6 Pages
6 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
4 Pages
2 Pages
4 Pages
3 Pages
4 Pages
2 Pages
4 Pages
4 Pages
8 Pages
16 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
16 Pages
34 Pages
3 Pages
2 Pages
4 Pages
2 Pages