SGM-101F

SGM-101F

SGM-101F

Product catalog summary

Product Overview

The SGM-101F is an ultrasonic transit time flow meter designed for both conductive and non-conductive fluids. It is suitable for wall mounting and can measure flow speeds up to ±12 m/s. The device simultaneously displays flow rate and cumulative volume data, with an optional heat meter feature.

Key Specifications

  • Accuracy: ±1%
  • Output Signals: 4-20 mA analog output, 1 open collector, and 1 relay output
  • Protection Rating: Transmitter IP66, Transducers IP68
  • Transducer Cable Length: Standard 5 meters
  • Fixing Accessories: Supplied with grease and steel hose clamps suitable for pipes up to DN900

Versions and Options

  • Versions: C (Heat meter with 15 m cables), D (Heat meter with 15 m cables + 8GB SD datalogger), U (8GB SD datalogger), W (Standard), Z (Special)
  • Power Supply Options: A (230 V AC), B (115 V AC), C (24 V AC), D (10-30 V DC), Z (Special)
  • Flow Transducers: Various clamp-on and insertion types for pipe diameters ranging from DN20 to DN4000, with temperature ranges from -40°C to 160°C. Specific models include TS-2, TM-1, TL-1, TS2H, TM1H, TL1H, TC-1, TLC2. Maximum cable length for transducers is 200 meters.
  • Additional Output: 4 (RS485 MODBUS), N (None), Z (Special)
  • Accessories: Options include MODBUS communication software, PT100 temperature sensors in various mounting configurations, metallic hose clamps for PT100 sensors, and special options.

Installation and Usage Notes

  • The device is designed for wall mounting and includes accessories for secure transducer fixing.
  • Suitable for a wide range of pipe sizes and fluid temperatures, including high-temperature applications.
  • Multiple power supply and output configurations allow integration into diverse industrial systems.

Contact Information

Manufacturer: LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire, LU4 8EZ, England
Telephone: +44 (0)1582 593693
Fax: +44 (0)1582 598036
Email: [email protected]
Website: www.lth.co.uk

See more

Catalog excerpts

SGM-101F-1

For conductive and non-conductive liquids Measure range <0.2m3/h to >400000m3/h Accuracy ± 1% Clamp on IP68 sensors also for high temperatures Pipedimension range: DN20 to DN4000 Datalogger via SD card or via MODBUS Heat meter The SGM-101F flowmeters operate on the ultrasonic pulses transit time difference principle. The great advantage is the mechanical installation, because it is not necessary to cut the pipe. The sensors are simply clamped on the outer pipe surface, for this reason the pressure and the liquid aggressiveness to be measured are not a problem for the fl owmeter. The system measures in a bidirectional way and is suitable for clean or slightly dirty liquids. TECHNICAL FEATURES Pipe dimension range DN20 to DN4000 Transmitter protection class IP66 Transducer protection class IP68 Display backlighted 2x20 alphanumeric digit Keypad 4 keys Housing material aluminium Displayed data instantaneous flowrate; flow totalizer Installation wall mounting Analog Output Sel. 4-20mA or 0-20mA Accuracy ±1% Repeatability ±0.2% Linearity ±0.5% Basic measurement period 500ms Serial port RS485 Communication protocol MODBUS RTU orASCII+ (opz.) Data logger on SD card (opt.) or via MODBUS Programmable frequency output 0-5000HZ Relay output n.1 for pulse totalizer or alarm Medium speed range ±12m/s Unit working temperature -20 to 60°C Instrument humidity non condensing 85% RH (40°C) Transducer working temperature TS-2/TM-1 /TL-1 -30 to +90°C;TS2H/TM1H-30 to+160°C; TC-1/ TLC2-40to +160°C PT100 sensors working temperature -40°C to +160°C Transducer cable std. length 5mt PT100 sensor cable std. length 15mt Power Supply 230vAC or 10-30vDC (depending on model) Dimensions 200x120x77mm Weight without sensors IKg LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England Telephone: +44 (0)1582 593693 Fax: +44 (0)1582 598036 email: [email protected] web: www.lth.co.uk

 Open the catalog to page 1
SGM-101F-2

ULTRASUONIC FLOW SGM-101F Transit time ultrasonic flow meter For conductive and non-conductive fluids. Wall mounting - Speed range: max ± 12m/s -Simultaneous display of flowrate and cumulative volume data Available with heat meter option Output: 4-20mA + 1 open collector + 1 relay Accuracy not better ± 1% Transducers standard connection cable 5 mt Protection degree: transmitter IP66 - transducers IP68 Supplied with grease and steel hose clamps for transducers fixing up to DN900 LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England Telephone: +44 (0)1582 593693 Fax: +44 (0)1582...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.