1. Catalogs
  2. LTH Electronics Ltd
  3. RSMag Electromagnetic Flowmeter

RSMag Electromagnetic Flowmeter

RSMag Electromagnetic Flowmeter

Product catalog summary
Specifications:
- Designed specifically for sanitary applications with SS304 sensor pipe.
- Accuracy options of ±0.2% and ±0.5%.
- DIN and CLAMP sanitary connections with PFA lining.
- Power supply options: 85 ÷ 265 Vac or 12; 24 Vac/Vdc.
- Data logging via USB pendrive.
- Configuration and display through VL701 with O-LED display.

Applications:
- Suitable for food and pharmaceutical industries, particularly for milk, beer, and other beverages.
- Completely manufactured in stainless steel.

Flow Rate and Measurement:
- Capable of processing fluid signals with flow rates up to 10m/s bidirectionally.
- Measurement range from 0 m3/h to 100 m3/h with repeatability of ±0.1%.
- Fluid conductivity requirement: >5 S/cm.

Power and Consumption:
- Power supply: 85÷265Vac, 24Vdc, 12Vdc.
- Consumption: 6W, max. 8W.

Temperature and Environment:
- Remote version operating temperature: -40 ÷ +150°C.
- Compact version operating temperature: -40 ÷ +100°C.
- Storage temperature: -40÷85°C.
- Humidity limits: 0-100% RH to 150 °F (65 °C), non-condensing.

Communication and Outputs:
- Communication options include Hart.
- Internal data logger with adjustable storage interval from 15 to 3600 seconds.
- Outputs: 4÷20mA, frequency output 0.1÷10000 Hz, pulse output, and alarm output.

Inputs and Testing:
- Two active analog inputs at 24Vdc for transmitters and one digital input for external contact connection.
- Reverse flow measurement and totalization capability.
- Output testing for relays, current source, and frequency source.

Additional Features:
- Low flow cutoff is adjustable.
- Damping adjustable between 1 and 99 seconds.
- Compact version IP rating: IP67.
- Remote version IP rating: sensor IP67 / IP68 (by request), converter IP67.
- Anti-condensation filter installed on converter.

Contact Information:
- LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England.
- Telephone: +44 (0)1582 593693
- Fax: +44 (0)1582 598036
- Email: [email protected]
- Website: www.lth.co.uk
See more

Catalog excerpts

RSMag Electromagnetic Flowmeter-1

RSMAG • Specific for sanitary applications • SS304 sensor pipe • ± 0.2% ; ± 0.5% accuracy • DIN and CLAMP sanitary connection • PFA lining • Power supply 85 * 265 Vac o 12; 24 Vac/Vdc • Datalogger via pendrive USB • Configuration and displaying via VL701with O-LED display RSmag flowmeters are suitable for applications in food and pharmaceutical industries. DIN11851 or Clamp ISO 2852 process connections are suitable for applications with milk, beer or other drinks. Manufactured completely in stainless steel, it is widely used in sanitary applications. TECHNICAL FEATURES Flow rate range RSmag is able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter). Range dimension / lining material DN25 - DN150/PFA Sensor pipe material SS304 Housing material epoxy painted aluminum Electrodes material SS316L - Hastelloy C - Titanium - Tantalum Measure range 0,6m3/h - 600m3/h Accuracy ±0,5% standard; ±0,2% opt Repeatability ±0,1% Fluid conductivity >5pS/cm Power supply 85-265Vac, 24Vdc, 12Vdc. Consumption 6W, max. 8W. Temperature range Remote version operating temperature: -40 - +150°C Compact version operating temperature: -40 - +100°C Storage temperature: -40-85°C Communication MODBUS RTU (opt) or Hart (PENDING) Data Logger Internal data logger to USB pen drive for flow measurements and analog inputs storing; the measurement storage interval can be set from 15 to 3600 seconds Output 4-20mA: 0-500D Frequency output: 0,1-10000 Hz Pulse output: 24Vdc galvanically isolated or open collector galvanically isolated 24V 20mA (opt) Alarm output: 2 relays, 3A 230Vac N.O. Input signals RSmag has 2 active analog inputs at 24Vdc for 2-wire transmitters connection (eg. Temperature or pressure) and 1 digital input for an external contact connection for the integrated batch function restart and for partial totalizer management. Reverse Flow Allows measure and totalization of reverse flow Output Testing Relays output: Transmitter can switch relays at testing value. Current Source: Transmitter can be commanded to supply a specifi ed test current between 4.0 and 20.0 mA. Frequency Source: Transmitter can be commanded to supply a specifi ed test frequency between 1 and 10000 Hz. Low Flow Cutoff Adjustable. Below selected value, instantaneous flow and outputs are driven to the zero fi ow rate signal level Humidity Limits 0-100% RH to 150 °F (65 °C), not condensing. Damping Adjustable between 1 and 99 seconds Compact version IP rating IP67 Remote version IP rating sensor IP67 / IP68 (by request) - converter IP67 Anti-condensation filter Anti-condensation fi lter installed on converter LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England Telephone: +44 (0)1582 593693 Fax: +44 (0)1582 598036 email: [email protected] web: www.lth.co.uk

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.