MXD70 SERIES
20Pages

{{requestButtons}}

Catalog excerpts

MXD70 SERIES - 1

MXD70 SERIESInstrumentation to meet your Process RequirementsFeatures The innovative MXD70 series of process instruments brings a new dimension to analytical process measurements with a modular design to meet ever changing process requirements. • MXD73 Compact 96 DIN IP66 Panel mount option • MXD75 IP66 Surface / Pipe mount version • 3%” QVGA Backlit LCD display provides clear indication as single or multiple measurements • Parameters include: Contacting and Electrodeless Conductivity, pH / Redox, Dissolved Oxygen, Suspended Solids, Turbidity and 4-20mA Current Input • Up to 3 measured parameters with temperature readings can be displayed together • User selectable bar graph display option • Plug and play card detection for simple measurement and output expansion upgrades • SD card interface allows trouble free saving of configuration and simplifies software updates • Base models include 2 relay outputs and a single isolated 4-20mA current output • Can be expanded up to 6 relay outputs and 6 isolated 4-20mA current outputs • Relays are fully configurable including on/off, time or pulse proportional operation • 8 Independent programmable digital inputs with user selectable operations • Power fail alarm • Dedicated error page provides up to date controller status • Modbus RS485 Communications interface • Data logging and live trending • Measurement Calculation functions • 85-265v or 18-32v Supply options (AC or DC) • User configurable measurement channel ident

Open the catalog to page 1
MXD70 SERIES - 2

Input Expansion Slots 3 slots, user configurable with any combination of available input add-in cards. Output Expansion Slots 1 slot, user configurable with an additional output option add-in card. Ambient Operating Temperature -20°C to +50°C (-4°F to +122°F) for full specification. Display 3%” QVGA back lit LCD module. Buttons 5 tactile feedback, micro-switched, silicone rubber. Alarm LED’s 2 Yellow LED's located above the main display area for instrument's alarm status, a lit LED indicates an alarm condition. Digital Inputs 8 separate inputs for remote activation of user defined...

Open the catalog to page 2
MXD70 SERIES - 3

MXD75 Instrument Specification Input Expansion Slots 3 slots, user configurable with any combination of available input add-in cards. Output Expansion Slots 1 slot, user configurable with an additional output option add-in card. Ambient Operating Temperature -20°C to +50°C (-4°F to +122°F) for full specification. Display 3%” QVGA back lit LCD module. Buttons 5 tactile feedback, micro-switched, silicone rubber. Alarm LED’s 2 Yellow LED's located above the main display area for instrument's alarm status, a lit LED indicates an alarm condition. Digital Inputs 8 separate inputs for remote...

Open the catalog to page 3
MXD70 SERIES - 4

• Displays conductivity, resistivity, ppm and temperature units • Measured process & temperature can be displayed together • Compliant with current USP requirements • Full ultra pure water temperature compensation • Ultra pure water to solution concentration measurement • Auto range, remote range or single range operation The contacting conductivity input allows connection with LTH contacting conductivity cells with a cell constant of K= 0.01,0.1, 1.0 and 10. It is also possible to use other manufacturer’s conductivity cells with a cell constant between K= 0.01 and 10. This offers a wide...

Open the catalog to page 4
MXD70 SERIES - 5

Range & Sensor Compatibility Tables CONDUCTIVITY RANGE Note 1: The maximum measurement range will be limited by the solution temperature. With the temperature compensation slope set to 2%/°C, this will derate linearly from full scale at 25°C to 50% of scale at 100°C.

Open the catalog to page 5
MXD70 SERIES - 6

• Displays conductivity, % solution concentration, salinity and temperature units • Able to simultaneously display conductivity, % solution concentration, salinity and °C • Ideal for cooling tower bleed, rinse water and solution concentration applications • Preset curves stored for common chemicals and salinity • 2 independent custom curves offering up to 9 points can be entered • Adjustable temperature compensation slope Covering a wide range of conductivity measurement, from water (200 pS/cm) to solution concentration measurements (1,000 mS/cm), it is possible to display the readings in...

Open the catalog to page 6
MXD70 SERIES - 7

Electrodeless Conductivity Input Card Specification Measurement Input ECS20 or ECS40 Series electrodeless conductivity sensor. Connection Cable Up to 100 metres LTH 54E or 54H cable. Ranges of Measurement 0-999.9|jS/cm, 0-9.999mS/cm, 0-99.99mS/cm, 0-999.9mS/cm. 0-999.9 ppm, 0-9999 ppm. 0-99.99 ppt (parts per thousand). 0 to 16.00% NaOH - Sodium Hydroxide. 0 to 30.00% NaCl - Sodium Chloride. 0 to 15.00% HCl - Hydrochloric Acid. 0 to 25.00% H2SO4 - Sulphuric Acid. 0 to 25.00% H3PO4 - Phosphoric Acid. 0 to 25.00% HNO3 - Nitric Acid. Linearity ±0.1% of range. Repeatability ±0.1% of...

Open the catalog to page 7
MXD70 SERIES - 8

• Differential input for excellent noise rejection • Accepts pH glass or Antimony and Redox (ORP) Electrodes • Able to simultaneously display the pH reading, temperature and electrode mv • Dose alarm timer prevents overdosing • Automatic sensor cleaning By providing the user with the flexibility to select either glass or Antimony pH sensors or Redox input and operating with single ended or differential inputs, means a single instrument may be used for the majority of pH and Redox applications. Temperature compensator selection of Pt100 or Pt1000 allows the instrument to be used with almost...

Open the catalog to page 8
MXD70 SERIES - 9

pH / Redox Input Card Specification Measurement Input Single ended or differential with solution ground. Connection Cable Up to 100 metres (No preamp required). LTH type 54E or LN10 cable. pH Separate glass and reference electrode pair. Combination electrode. Redox Separate glass and reference electrode pair. Combination electrode. Other manufacturer's sensors can be accommodated. Ranges of Measurement 0.00-14.00pH, 0.000 to 14.000pH, -1999 to +1999mV. Accuracy ± 0.050pH, ±3mv. Linearity ±0.1% of range. Repeatability ±0.1% of range. Operator Adjustment Custom Buffer 13 point 4pH / 9pH...

Open the catalog to page 9

All LTH Electronics Ltd catalogs and technical brochures

  1. RBMAG

    4 Pages

  2. SGM-200H

    2 Pages

  3. SGM-101F

    2 Pages

  4. Flowmeter

    2 Pages

  5. BXD17 Series

    12 Pages

  6. 8000 Series

    6 Pages

  7. 2000 Series

    6 Pages

  8. IET40

    4 Pages

  9. ECS40 Series

    4 Pages

  10. ECS20 Series

    4 Pages

  11. HD23060

    4 Pages

  12. MLC Series

    4 Pages

  13. Dynaprobe

    2 Pages

  14. HD23050

    4 Pages

  15. PG135

    3 Pages

  16. PME20 WPA1

    4 Pages

  17. 9000

    2 Pages

  18. ECS40

    4 Pages

  19. ECS20

    4 Pages

  20. MTD75

    8 Pages

  21. MXD70 series

    16 Pages

  22. AquaCal 2000

    4 Pages

Archived catalogs

  1. SWING

    2 Pages

  2. SMAG62

    4 Pages

  3. SGM100H

    4 Pages

  4. SGM100F

    4 Pages

  5. PTU Series

    2 Pages

  6. PMAG

    4 Pages

  7. HET63

    4 Pages

  8. BC9 Series

    3 Pages

  9. CDM9

    34 Pages

  10. HOT63

    4 Pages