The document describes the specifications and features of an ultrasonic open channel flow control unit designed by LTH Electronics Ltd. This device is compact and suitable for upstream installation in various configurations such as weir, Venturi, and Palmer Bowlus, both standard and non-standard.

Specifications:
  • Connection: G 2"A / PP threaded connection with a 2" BSP/PP fixing bolt.
  • Output: 4-20mA output for instantaneous flow transmission.
  • Relays: Two relays are included; one for impulses/volume transmission and another for threshold alarm or diagnostic purposes.
  • Communication: MODBUS RTU output is available.
  • Temperature Range: Operates between -20° to +60°C.

Versions and Materials:
  • Version 0: 4-wire, MODBUS, range 5m.
  • Version 9: Special version.
  • Housing/Sensor Materials: Options include PC with transparent cap, IP67 / PP, Aluminum with transparent cap, IP67 / PP, and special materials.

Power Supply Options:
  • 24vDC (20-30vDC).
  • 12vDC (max 20vDC).
  • Special power supply options.

Accessories:
  • None.
  • DN80 PN6 UNI 6091-71/PP flange (600J001T).
  • VL601 keyboard/display programming module (VL601SGM).
  • MODBUS RTU communication software (010F119A).
  • Special accessories.

Contact Information:
LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire, LU4 8EZ, England. Telephone: +44 (0)1582 593693, Fax: +44 (0)1582 598036, Email: [email protected], Website: www.lth.co.uk
See more

Catalog excerpts

Flowmeter-1

Compact system suitable to be installed upstream of hydraulic modellers (weirs, venturi, palmer bowlus) Solution with excellent price performance ratio Instantaneous and totalized flow measurement No. 2 freely programmable relays MODBUS communication protocol Flowmeter is an ultrasonic flow transmitter, temperature-compensated and suitable for connection with MODBUS RTU acquisition systems. FLOWMETER in addition to an analog output includes two freely addressable relay for flow threshold or for totalizer pulse output. TECHNICAL FEATURES Housing/sensor material PC or Al / PP wetted part (only PVDF for ATEX certified vers.) Mechanical installation 2” GAS M (PP flange DN80 opt.) Protection degree IP67/IP68 (Sensor) Electrical connection Internal push connectors Working temperature -30 to +70°C; +80°C non-continuous Pressure from 0.5 to 1.5 bar (absolute) Power supply 12vDC/24vDC Power consumption 1.5W Analog output 4-20mA, max 750ohm (4-wire versions) Relays output n°2 3A 230vAC (n.o.) Digital communication MODBUS Max measure range max 0.25-5m In case of non perfectly reflecting surfaces, the maximum distance value will be reduced Blind distance 0.25m Temperature compensation digital from -30 to 80°C Accuracy ±0.2% (of the measured distance) not better than ±3mm. Resolution 1mm. Calibration 4 buttons or via MODBUS Warm-up 5 minutes typical LCD Display Plug-in display/keyboard 4 buttons matrix LCD

 Open the catalog to page 1
Flowmeter-2

OPEN CHANNEL FLOW FLOWMETER Ultrasonic open channel flow control unit Compact - Suitable for upstream installation in weir, Venturi, Palmer Bowlus (standard and non-standard) G 2"A / PP threaded connection + nr. 1 2" BSP/PP fixing bolt 4-20mA output with instantaneous flow transmission Relay nr. 1 for impulses/volume transmission Relay nr. 2 for threshold alarm or diagnostic MODBUS RTU output. Housing with anti condensation filter Temperature range : -20° to +60°C LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England Telephone: +44 (0)1582 593693 Fax: +44 (0)1582 598036 email:...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.