Overview: The ECS40 Series PEEK™ Electrodeless Conductivity Sensors offer a low-maintenance solution for measuring conductivity in various industrial applications, including brewing, dairy, food, and process industries. These sensors are designed for inline, tank, and open tank mounting, with several hygienic flange options available.
Material and Construction: The sensors are constructed from PEEK™, a food-grade material known for its chemical resistance and high-temperature performance. They can operate continuously at 100°C and withstand thermal shocks, making them suitable for CIP applications and steam sterilization up to 135°C.
Temperature and Compatibility: Equipped with Pt1000 temperature sensors, the ECS40 series ensures fast temperature response (t90 < 10 seconds) and is compatible with all LTH Electrodeless conductivity instruments. The sensors feature an IP67 connection for simplified installation and maintenance.
Specifications: The sensors are available with various cable lengths and connection options. They can handle maximum continuous temperatures of 100°C and short-term exposure up to 135°C. The sensors are designed to withstand pressures up to 150 psi (10 Bar) depending on the model.
Product Variants: The ECS40 series includes multiple models, each with specific features such as different mounting options, wetted materials, and temperature pockets. For example, the ECS42T model is a PEEK DIP sensor with a stainless steel dip tube, while the ECS43T is an inline sensor with a PVC Tee.
Compliance and Ordering: These products comply with current European Directives. Various cable lengths and sensor models are available, with additional options upon request. Customers are advised to contact the sales department for further details.
See more

Catalog excerpts

ECS40 Series-1

ECS40Series PEEK™ Electrodeless Conductivity Sensors • Low Maintenance. • Steam Sterilisable to 135°C, Thermal Shock Resistant. • Hygienic, Inline, Dip and Tank Mounting Options. • IP67 Connection Simplifies Installation and Maintenance. • Ideal for Brewing, Dairy, Food and Process Applications. • Fast Temperature Response t90 < 10 secs • Conductivity and Solution Concentration Measurements. The Electrodeless method of measuring conductivity has many advantages over conventional methods. In particular the sensors will operate with virtually zero maintenance and provide reliable measurements over extended time periods. The ECS40 sensors can be mounted inline, in a tank wall, large bore pipe or in an open tank using a variety of fittings. The option of several different hygienic flanges caters for the majority of applications. The sensor is manufactured in PEEK™ a food grade material with excellent chemical resistance and high temperature performance. The construction of the sensor allows it to operate at 100°C continuously, withstand thermal shocks commonly associated with CIP applications and the sensor can be steam sterilised up to 135°C. The sensors are fitted with Pt1000 temperature sensors and are compatible with all LTH Electrodeless conductivity instruments. The temperature sensor is mounted in direct contact with the medium via a stainless steel jacket with an alternative PEEK jacket available for applications where stainless steel might be unacceptable. Connection is made via an IP67 plug which simplifies installation and maintenance.

 Open the catalog to page 1
ECS40 Series-2

ECS/43T ECS/45T NETTED MATERIALS PEEK (SENSOR BODY) 316 ST/BTL CT/C HOUSING 8 SCREWED TEE)

 Open the catalog to page 2
ECS40 Series-3

Specification Hygienic Flanges Suffix T Temperature sensor: Standard Sizes RJT: 2”, 2.5”, 3” Tri clamp: 2”, 3” IDF/ISS: 2”, 2.5”, 3” DIN 1185: 50mm, 80mm Common Specification Class A Pt1000 RTD Temperature Thermal shock: Response T90 LTH Electronics www.lth.co.uk Maximum continuous, 100°C, subject to material compatibility with solution. Short term 30 mins 135°C. 10°C per second. Less than 10s - stainless steel temperature pocket. Less then 2.5 mins - PEEK temperature pocket. Notes: Flanges for the ECS49 sensors must be ordered seperately. Minimum pipe size for insertion sensors 2.5”, 63.5mm....

 Open the catalog to page 3
ECS40 Series-4

Electronics www.lth.co.uk Order Codes ECS40 Series Electrodeless Conductivity Sensor Connection Cables ^ ^ These products comply with current European Directives / \ Hw. LTH Electronics Ltd reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued y J developments and improvements. All care has been taken to ensure the accuracy of information contained in this data sheet. y However we cannot accept responsibility for any errors or damages resulting from errors or inaccuracies of information contained herein. Issue: 0314 Certificate...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.