Overview: The 9000 Series pH & Redox Insertion Sensors are designed for direct installation into pipes or tank walls for continuous monitoring and control of pH or Redox levels. These sensors feature a combination glass pH electrode and a sealed Ag/AgCl reference with a coaxial ceramic junction.
Design and Installation: The sensors have a large non-clogging peripheral reference junction constructed in an annular form around the sensing electrode. They are made with a Kynar body and have a 0.5” NPT male threaded process connection. For optimal performance, sensors should be installed at least 15° above horizontal.
Specifications:
  • pH Range: 0–13 pH
  • ORP Range: ± 5000 mV
  • Temperature Range: -5º to 105ºC
  • Max Pressure/Temp: 100 psig at 100ºC, 150 psig at 25ºC
  • Reference System: Ag/AgCl
  • Reference Electrolyte: 3.8M KCl, Saturated with AgCl
  • Glass Membrane Type: HT-3, Low Sodium Ion error
  • Membrane Resistance: 100 Megohms
  • Zero Potential: 7.0 pH
  • Wetted Materials: Kynar, Glass, and Ceramic
  • Standard Cable Length: 6 Metres low noise coaxial cable with Tag ends
Product Variants:
  • 9027: 0.5” NPT Male threaded pH sensor with 6 metres of cable & Tag ends (Orange body)
  • 9126: 0.5” NPT Male threaded Redox sensor with 6 metres of cable & Tag ends (Grey body)
Additional Information: The life expectancy of the sensors is influenced by temperature, pressure, and solution composition. These products comply with current European Directives. LTH Electronics reserves the right to make changes to the product or data sheet without notice.
See more

Catalog excerpts

  9000 Series    Insertion pH / Redox Electrodes-1

9000 Series pH & Redox Insertion Sensors • Combination glass pH electrode, • Sealed Ag/AgCl reference with coaxial ceramic junction • Single junction reference design • 6 Metres of cable with Tag ends (* Note: Dimensions in inches) The 9000 series pH & Redox sensors are designed for direct installation into a pipe or in the wall of a tank for continuous pH or Redox monitoring and control. These sensors have a large non-clogging peripheral reference junction, which is constructed in annular form around the sensing electrode. The 9000 series sensors have a Kynar body with a 0.5” NPT male threaded process connection. The sensors must always be installed at least 15 ° above horizontal for correct operation.

 Open the catalog to page 1
  9000 Series    Insertion pH / Redox Electrodes-2

SPECIFICATIONS pH Range 0–13 pH ORP Range ± 5000 mV Temp Range -5º to 105ºC Max Pressure/Temp 100 psig at 100ºC, 150 psig at 25ºC Reference System Ag/AgCl Reference Electrolyte 3.8M KCl, Saturated with AgCl Glass Membrane Type HT-3, Low Sodium Ion error Membrane Resistance 100 Megohms Zero Potential 7.0 pH Wetted Materials Kynar, Glass and Ceramic Standard cable length 6 Metres low noise coaxial cable with Tag ends Order Codes Type No Part No Description 9027 138/007 0.5” NPT Male threaded pH sensor fitted with 6 metres of cable & Tag ends (Body colour Orange) 9126 138/054 0.5” NPT Male threaded...

 Open the catalog to page 2

Archived catalogs

  1. PMAG

    4  Pages

  2. SMAG62

    4  Pages

  3. RPL 50 Series

    8  Pages

  4. HOT63

    4  Pages

  5. HET63

    4  Pages

  6. SGM100H

    4  Pages

  7. CDM9

    34  Pages

  8. BC9 Series

    3  Pages

  9. PTU Series

    2  Pages

  10. SGM100F

    4  Pages

  11. SWING

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.