2000 Series - 1

‘INTELLIGENT’ PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 “ALL STAINLESS” DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 mA AND HART® PROTOCOL ATEX WIDE RANGEABILITY LOCAL DISPLAY ADJUSTABLE DAMPING MORE THAN 40 DIFFERENT PROCESS CONNECTIONS PROFIBUS-PA Description The Series 2000 is a complete range of ‘intelligent’ pressure and level transmitters with local display and adjustment by three pushbuttons. The pushbuttons are used to set Zero and Span. Test pressures are not required for calibration. Stainless steel housing The display which can indicate a number of chosen engineering units is also used during programming to assist the easy operation. Process temperatures can be shown and damping times can be adjusted from 0 to 25 secs. Also a 4-20 mA Current Simulation can be performed. The Series 2000 is fully temperature compensated. Over 40 different process connections are available including many flush diaphragm designs. Options include ATEX approval, HART® protocol or PROFIBUS-PA output. HART® is a registered trademark of the HART Communication Foundation Nijverheidsweg 5 P.O. Box 13 Tel. +31-521-591550 Fax +31-521-592046 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands Website:

Open the catalog to page 1
2000 Series - 2

Description The series 2000 pressure transmitter has been specially designed for measuring pressure in pulp-and paper mills and similar industries where plugging is a problem. The transmitters are fully temperature compensated, and have very strong, flush mounted diaphragms. Zero and span can be adjusted without testpressure by 3 pushbuttons or by hand-held-terminal (HART®,option). Process connections Code W Weld-on nipple 0 33 mm Specifications Accuracy Measuring ranges Output signal Adjustment Power supply External load Protection grade Process temperature Ambient temperature Temperature...

Open the catalog to page 2
2000 Series - 3

Description The 2000-SAN series are designed for all pressure and level measurements in the food and beverage, chemical and pharmaceutical industries. All hygienic process connections are available, most of them are according to the EHEDG, 3-A and FDA regulations. The transmitters are fully temperature compensated, and have very strong, flush mounted diaphragms. Zero and span can be adjusted without testpressure, over wide ranges, by 3 pushbuttons, or hand-held terminal (HART®, option). Process connections Code M Milkcoupling (DN 25, 40 or 50) Code F Flange (DIN or ANSI) Specifications...

Open the catalog to page 3
2000 Series - 4

Description The Peramic ‘S’, series CER-2000, is a pressure transmitter based on a ceramic measuring sensor. The CER-2000 series is fully temperature compensated and is made for all pressure applications in clean liquids, gases and vapours. The ceramic measuring cell can withstand high overpressures, and is sealed by an o-ring (viton as standard, other materials on request). Zero and span can be adjusted without testpressure over wide ranges, by 3 pushbuttons or by a hand-held terminal (HART®, option). Process connections Code R 1/2" BSP (DIN 16288) Dimensions (mm) Specifications Accuracy...

Open the catalog to page 4
2000 Series - 5

General information series 2000 Calibration Adjustable points As standard the Series 2000 is always equipped with a display and 3 pushbuttons for easy calibration. Both the measured and the calibrated value can be read locally. A full calibration can be completed using the three pushbuttons or with the optional handheld terminal (HART®), or with special software from Klay Instruments. Cancel mounting position effect Adjustment pressure unit (see conversion table) Zero and span can be calibrated very easy, without testpressure, also in vacuumranges. Linearisation can be made for various...

Open the catalog to page 5
2000 Series - 6

f SERIES 2000 (info on page 2) SERIES 2000 - PROCESS CONNECTIONS: - Weld-on nipple diam. 33 mm. (flush diaphragm / pulp & paper) - G1" (1"BSP) threaded connection (flush diaphragm) - PASVE 1" connection (Valmet/Satron) - Other process connections: i.e. PMC(X2), Valcom, Vega, etc. (specify X code) OPTIONS: - Transparant cover, display functions as local indicator -Vacuum Ranges (Specify Relative or absolute) Compound ranges available (example -1 /+1 bar) - Intrinsically safe: ATEX I11 G Ex ia IIC T4 Ga and/or I11 D Ex ia IIIC T100°C Da IP6X - HART® Protocol SERIES 2000-SAN (info on page...

Open the catalog to page 6

All LTH Electronics Ltd catalogs and technical brochures

  1. RBMAG

    4 Pages

  2. SGM-200H

    2 Pages

  3. SGM-101F

    2 Pages

  4. Flowmeter

    2 Pages

  5. MXD70 SERIES

    20 Pages

  6. BXD17 Series

    12 Pages

  7. 8000 Series

    6 Pages

  8. IET40

    4 Pages

  9. ECS40 Series

    4 Pages

  10. ECS20 Series

    4 Pages

  11. HD23060

    4 Pages

  12. MLC Series

    4 Pages

  13. Dynaprobe

    2 Pages

  14. HD23050

    4 Pages

  15. PG135

    3 Pages

  16. PME20 WPA1

    4 Pages

  17. 9000

    2 Pages

  18. ECS40

    4 Pages

  19. ECS20

    4 Pages

  20. MTD75

    8 Pages

  21. MXD70 series

    16 Pages

  22. AquaCal 2000

    4 Pages

Archived catalogs

  1. SWING

    2 Pages

  2. SMAG62

    4 Pages

  3. SGM100H

    4 Pages

  4. SGM100F

    4 Pages

  5. PTU Series

    2 Pages

  6. PMAG

    4 Pages

  7. HET63

    4 Pages

  8. BC9 Series

    3 Pages

  9. CDM9

    34 Pages

  10. HOT63

    4 Pages