Catalog excerpts

LTG Air-Water Systems-1

Technical Brochure Induction units HFFsuite For hotel bedrooms, ceiling installation

 Open the catalog to page 1
LTG Air-Water Systems-2

The Innovation Company LTG Aktiengesellschaft Technical brochure Induction units HFFsuite for hotel bedrooms, ceiling installation Content LTG Comfort Air Technology View of unit, application, installation/placement, function, advantages, design, accessories Installation examples Technical data Control, wiring diagram Notes Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Tolerances according to DIN ISO 2768-vL. For the outlet grille special tolerances stated in the drawing apply. Straightness and twist tolerances for extruded aluminium profiles...

 Open the catalog to page 2
LTG Air-Water Systems-3

The Innovation Company LTG Aktiengesellschaft Technical brochure Induction units HFFsuite for hotel bedrooms, ceiling installation View of unit With the 2-pipe unit it is possible to have cooling only, or cooling/reheating with a change-over circuit. The supply air is diffused into the room via permanently pre-adjusted baffle plates as a ceiling (Coanda)jet. The active induction check (optional) allows the unit to be "switched off". Only the centrally set primary air flow rate then provides basic ventilation for the necessary air change. Advantages  Low primary pressures - Low-noise operation...

 Open the catalog to page 3
LTG Air-Water Systems-4

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Dimensions without condensate tray, 2-pipe system, standard Isometric views Detachable sliding type fitting Back view © LTG Aktiengesellschaft • GrenzstraUe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 4
LTG Air-Water Systems-5

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Dimensions with condensate tray, 2-pipe system refer to the the unit without condensate tray (page 4) © LTG Aktiengesellschaft • GrenzstraUe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 5
LTG Air-Water Systems-6

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Dimensions size 900, without condensate tray, with electrical heating element, 2-pipe system Front view Isometric views Back view Lateral view left side refer to 2-pipe unit without condensate tray (page 4) © LTG Aktiengesellschaft • GrenzstralJe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 6
LTG Air-Water Systems-7

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Dimensions without condensate tray, 4-pipe system Isometrische Ansichten Front view Lateral view left side © LTG Aktiengesellschaft • GrenzstraUe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 7
LTG Air-Water Systems-8

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Dimensions with condensate tray, 4-pipe system Cut A - A View from below Back view refer to 4-pipe unit without condensate tray (page 7) © LTG Aktiengesellschaft • GrenzstralJe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 8
LTG Air-Water Systems-9

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Installation ex. size 900, without condensate tray, with valve assembly V3T, 2-/4-pipe system Isometric view HFF-eng-TP (08/13) page 9 of 19 © LTG Aktiengesellschaft • GrenzstraUe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 9
LTG Air-Water Systems-10

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installation Installation example size 900, with condensate tray, 2-pipe and 4-pipe system Detail B Lateral view right side refer to size 900 without condensate tray (page 9) © LTG Aktiengesellschaft • GrenzstralJe 7 • 70435 Stuttgart • Germany Printed in Germany ■ Former editions are invalid ■ Subject to technical modifications

 Open the catalog to page 10
LTG Air-Water Systems-11

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installationTechnical data size 900, 2-pipe system, non condensing Nozzle (1) Secondary cooling capacity (heat exchanger, non condensing), troom = 26°C, tKWVL = 16 °C (cold water supply) (2) Primary cooling capacity, (3) Heating capacity (heat exchanger), troom = 22°C, tWWVL = 55 °C (warm water supply, (4) Cooling capacity (heat exchanger, condensing), troom = 26°C, tKWVL = 6 °C (cold water supply) (5) Cooling capacity 7 % less with eletrical heating element Nozzletypesize900 see page 13. Ap - static pressure at the primary...

 Open the catalog to page 11
LTG Air-Water Systems-12

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installationTechnical data size 1200, 2-pipe system, non condensing Dusen- (1) Secondary cooling capacity (heat exchanger, non condensing), troom = 26°C, tKWVL = 16 °C (cold water supply) (2) Primary cooling capacity, (3) Heating capacity (heat exchanger), troom = 22°C, tWWVL = 55 °C (warm water supply, (4) Cooling capacity (heat exchanger, condensing), troom = 26°C, tKWVL = 6 °C (cold water supply) (5) Cooling capacity 7 % less with eletrical heating element Legend see page 11 Nozzle type size 1200 The nozzle type defines...

 Open the catalog to page 12
LTG Air-Water Systems-13

Technical brochureInduction units HFFsuite for hotel bedrooms, ceiling installationTechnical data size 900, 4-pipe system, non condensing Nozzle (1) Secondary cooling capacity (heat exchanger, non condensing), troom = 26°C, tKWVL = 16 °C (cold water supply) (2) Primary cooling capacity, (3) Heating capacity (heat exchanger), troom = 22°C, tWWVL = 55 °C (warm water supply, (4) Cooling capacity (heat exchanger, condensing), troom = 26°C, tKWVL = 6 °C (cold water supply) The nozzle type defines air volume and pressure curve. © LTG Aktiengesellschaft • GrenzstraUe 7 • 70435 Stuttgart • Germany Printed...

 Open the catalog to page 13