Floor-mounted Free-jet Air Diffuser Type BLA LTG Aktiengesellschaft D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-0, Fax +49 (0711) 82 01-720 Internet: http://www.LTG-AG.de E-Mail: info@LTG- AG.de - LTG Incorporated 105 Corporate Drive, Suite E Spartanburg S.C., 29303 USA +1 (864) 599- 6340, Fax +1 (864) 599- 6344 Internet: http://www.LTG-INC.net E-Mail: info@LTG- INC.net -
Open the catalog to page 1Components for Room Air Technology Germany Central Office (Frankfurt) Sales area: PLZ 54, 55, 60, 63, 64, 66-69, 97 Sontraer Str. 27 D-60386 Frankfurt am Main (069) 94 20 19-14, Fax -10 E-mail: Bergmann@LTG-AG.de Central office (Herborn) Sales area: PLZ 30, 31, 34-38, 56, 57, 61, 65 Sperberweg 16 D-35745 Herborn Herr Hartmann (02772) 570-725, Fax -727 E-mail: Hartmann@LTG-AG.de Eastern office (Berlin) Sales area: PLZ 10-25, 29, 39 Eisenhutweg 51a D-12487 Berlin Herr Linke (030) 63 22 87-74, Fax -75 E-mail: Linke@LTG-AG.de Eastern office (Chemnitz) Sales area: PLZ 01-09, 98, 99...
Open the catalog to page 2Floor-mounted Free-jet Air Diffuser Type BLA Application The floor- mounted air diffuser type BLA has been developed for rooms which are subjected to high thermal loads, for example: computer suits, laboratories, offices, dealer rooms, multi- purpose halls. - Function The BLA floor- mounted diffuser is a highly inductive free- flow diffuser. The supply air is diffused vertically upwards from the floor and fanned out in individual jets. These jets cause the difference in velocity and temperature between the supply air and room air to be rapidly decayed. This results in a very stable jet...
Open the catalog to page 3Floor-mounted Free-jet Air Diffuser Type BLA Floor-mounted air diffuser type BLA (Diffuser plate with dirt trap and throttle slides) Floor-mounted air diffuser type BLA with carpet ring and retaining ring (for false floor) Floor-mounted air diffuser type BLA with carpet ring and toggle clamps (for hollow space floor) Range Diffuser plate Nominal diameter: 150 mm Volume flow per diffuser: 30 ... 60 m3/h Design: Fiberglass- reinforced Makrolon, colour* on request similar RAL. Dirt trap with throttle slides Design: Makrolon, graphite black, similar to RAL 9011. Carpet ring with retaining ring...
Open the catalog to page 4Floor-mounted Free-jet Air Diffuser Type BLA spec. total cooling load [W/m2] 0.6 thermal load: at floor level at table- top height - 0.2 distance d between the diffusers [mm] 600 spec. cooling load2 in the mixing zone [W/m ] t = -4K Temperature diff. t = tSU - tRM,mix tSU = temperature supply air tRM,mix = mean room temperature in the occupied zone Design diagram for floor- mounted air diffuser Type BLA (conditioned zone h = 1.8 and 1.5 m) - Design example: Wtot The diagram can be used to determine Given: Total cooling load Availble room area Atot maximum air volume per diffuser, the Spec....
Open the catalog to page 5Distance from centre of diffuser [m] h: vertical distance from diffuser normally occupied zone Temperature distribution over the room height "Velocity curves Example, where V = 40 m3lh per diffuser. At ~ - 4.0 K with 6 open slots results a sound power level of A-weighted sound power level of the floor-mounted air diffuser type BLA Sound power levei^ open slots dirt trap dirt trap © LTG Aktiengesellschaft • GrenzstraBe 7 • D-70435 Stuttgart • « +49 (0711) 8201-0 Internet: http://www.LTG-AG.de • E-Mail: info@LTG-AG.de • Printed in Germany • Former editions are invalid • Subject to technical...
Open the catalog to page 6Floor-mounted Free-jet Air Diffuser Type BLA Installation Installation optionss: - Insertion into the floor (step drilling, exterior Ø 150 mm, depth 21.5 mm, step drilling, interior Ø 136 mm). - Fastening using a carpet ring and a retaining ring (through drilling Ø 159 mm). - Fastening using a carpet ring and toggle clamps (through drilling Ø 159 mm, with a 25 mm minimum thickness of the floor) A flexible duct connection with plenum box, nominal diameter 80 mm, can be used for installation in raised floors, then the sound power level is increased by 3 dB. lt is possible to install up to...
Open the catalog to page 7Floor-mounted Free-jet Air Diffuser Type BLA Insertion into the floor (standard) Step drilling, exterior Ø 150 +0,5 Air diffuser BLA Ø 149.5 +0.2 Throttling slide Step drilling, interior Ø 136 - 0.1 Fastening using carpet ring and toggle clamps (hollow space floor) Ø 80 132 Hollow space floor 3 toggle clamps per diffuser Diffuser plate RAL Nr. Dirt trap = without dirt trap K0 = with dirt trap, without throttling slides K 1..8 M = with dirt trap with 1..8 throttling slides, factory set K 1..8 V = with dirt trap with 1..8 throttling slides enclosed Carpet ring RAL Nr. Installation - =...
Open the catalog to page 8Specification and Schedule of Prices Floor-mounted free-jet Air Diffuser BLA Edition 7.7.2009 / page 1 Qty. Highly inductive free-flow diffuser with an expelled air range of 60°, designed for installation in raised floors. Easily accessible dirt trap with gradually adjustable throttle slides. Easy half-width and complete closing as well as subsequent adjustment after installation possible. Diffuser plate for a fine splitting of the air jet into 20 individual microjets. Antiskid surface. Floor-mounted diffuser acc. to IBM directive: class 1.2. Breaking load > 10000 N with steel rollers (Ø =...
Open the catalog to page 9All LTG Aktiengesellschaft catalogs and technical brochures
-
LTG Centrifugal Separators
10 Pages
-
LTG Fibre Compactor
14 Pages
-
LTG Air Distribution
16 Pages
-
LTG Air-Water Systems
32 Pages
-
Product Overview Air Diffusers
28 Pages
-
Swirl Diffusers Type DLA
28 Pages
-
LTG cool wave®
53 Pages
-
Fancoil Units floor mounted
39 Pages
-
Facade fancoil unit FVD
35 Pages
-
Facade fancoil unit FVS
24 Pages
-
Facade fancoil unit FVM
16 Pages
-
Flow-Rate Controller Type VRE-W
14 Pages
-
Flow-Rate Controller Type VRF-W
16 Pages
-
Flow-Rate Controller Type VRD-W
16 Pages
-
Silencers
10 Pages