Fancoil Units Perimeter Installation
58Pages

{{requestButtons}}

Catalog excerpts

Fancoil Units Perimeter Installation - 1

Technical Documentation Fan Coil Units for Perimeter Installation Example: Type VFC 630 LTG Incorporated 105 Corporate Drive, Suite E Spartanburg S.C., 29303 USA +1 (864) 599-6340, Fax +1 (864) 599-6344 www.LTG-INC.net info@LTG-INC.net

Open the catalog to page 1
Fancoil Units Perimeter Installation - 2

Fan Coil Units for Perimeter Installation Content Page Application, Functionality, Advantages, heating/cooling capacity, pressure loss 17 Speed control wiring diagrams 38 Installation, brackets, water connections 39 Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Forthe outlet grille special tolerances stated in the drawing Straiahtness and twist tolerances for extruded aluminum The surface finish is designed to meetthe requirements for applications in buildings - room climate according to DIN 1946 part 2. Other requirements on...

Open the catalog to page 2
Fancoil Units Perimeter Installation - 3

The Innovation Company LTG Aktiengesellschaft LTG Fan coil units Room airflow LTG offer air diffusion by various techniques: - Mixed/displacement flow from the sill - Tangential flow from the sill - Air displacement from the sill - IndiventR flow from the ceiling Versatile Range Types LTG offers differents types for any application. The main distinctive feature of the LTG fan coil units is the way the temperature is controlled. Two-pipe system The fan coil unit has only one heat exchanger through which chilled water flows for cooling and hot water for heating. Thus, it is only possible to...

Open the catalog to page 3
Fancoil Units Perimeter Installation - 4

The Innovation Company LTG Aktiengesellschaft Fan coil units for perimeter installation Product Overview Type Standard unit For extremely low inlet temperatures Upright unit with fresh air supply by LTG linear air diffuser type LDB Upright unit with fresh air supply by fresh air box Upright unit with solid floor fixation With energy-saving EC motor Particularly small built-in depth and height For high demands on acoustics Displacement fan coil unit for particularly high demands on comfort Standard unit For extremely low inlet temperatures Upright unit with fresh air supply by LTG linear air...

Open the catalog to page 4
Fancoil Units Perimeter Installation - 5

The Innovation Company LTG Aktiengesellschaft Fan coil units for perimeter installation Series VFC Unit view Operation principle The tangential fan of the VFC draws in ambient air. This air passes through a heat exchanger (cooling or heating) and is then returned into the room. Output control is water-side using valves. Neues Bild Fan coil unit for perimeter installation Type VFC Application The fan coil unit type VFC has been specifically designed for hotels and office buildings with strict acoustic requirements. It offers versatile possibilities for design of air distribution systems....

Open the catalog to page 5
Fancoil Units Perimeter Installation - 6

The Innovation Company LTG Aktiengesellschaft Fan Coil Units for Perimeter Installation Type VFC-4/F Specification Dimensions, Weights Fan coil unit with one heat exchanger with two separate water cycles for heating and cooling the ambient air. Water-side control by valves. Particularly small built-in depth and height, therefore especially appropriate for a room-saving perimeter installation. For extremely low inlet temperatures the unit is available with an insulated drain tray (see page 10). Vertical installation. Water connection on the right or left. * approx. values, depending on...

Open the catalog to page 6
Fancoil Units Perimeter Installation - 7

The Innovation Company LTG Aktiengesellschaft Fan Coil Units for Perimeter Installation Type VFC-4/F Technical data size 500 n [-] I II III IV V wok /pw woh/pw [kg/h]/[kPa] [kg/h]/[kPa] wok /pw woh/pw [kg/h]/[kPa] [kg/h]/[kPa] wok /pw woh/pw [kg/h]/[kPa] [kg/h]/[kPa] wok /pw woh/pw [kg/h]/[kPa] [kg/h]/[kPa] wok /pw woh/pw [kg/h]/[kPa] [kg/h]/[kPa] Technical data size 630 n [-] I II III IV V Technical data size 800 n [-] I II III IV V Technical data size 1000 n [-] I II III IV V Technical data size 1250 n [-] I II III IV V 1) Specific cooling capacity (non-condensing operation) 2) Cooling...

Open the catalog to page 7
Fancoil Units Perimeter Installation - 8

The Innovation Company LTG Aktiengesellschaft Fan coil units for perimeter installation Type VFC-2/F Specification Dimensions, weights Fan coil unit with one heat exchanger for heating or cooling the ambient air. Water-side control by valves. Particularly small built-in depth and height, therefore especially appropriate for a room-saving perimeter installation. For extremely low inlet temperatures the unit is available with an insulated drain tray (see page 11). Vertical installation. Water connection on the right or left. * approx. values, depending on execution Side view, right side Air...

Open the catalog to page 8
Fancoil Units Perimeter Installation - 9

The Innovation Company LTG Aktiengesellschaft Fan coil units for perimeter installation Type VFC-2/F Technical data size 500 n [-] I II III IV V Technical data size 630 n [-] I II III IV V Technical data size 800 n [-] I II III IV V Technical data size 1000 n [-] I II III IV V Technical data size 1250 n [-] I II III IV V 1) Specific cooling capacity (non condensing operation) 2) Cooling capacity with the following parameters: water inlet 6_C, air inlet: 26_C, 50% rel. humidity Legend n - speed V - flow rate (approx. values, tolerance ¦10%) LA18 - sound pressure level LwA - sound power level...

Open the catalog to page 9
Fancoil Units Perimeter Installation - 10

The Innovation Company LTG Aktiengesellschaft Fan coil units for perimeter installation Type VFC-4/F/Z, for extremely low inlet temperatures Specification Dimensions, weights Fan coil unit with one heat exchanger and two separate cycles for heating or cooling the ambient air. Water-side control by valves. Particularly small built-in depth and height, therefore especially appropriate for a room-saving perimeter installation. For extremely low inlet temperatures an insulated drain tray is available for insertion on site. Vertical installation. Water connection on the right or left. * approx....

Open the catalog to page 10
Fancoil Units Perimeter Installation - 11

The Innovation Company LTG Aktiengesellschaft Fan coil units for perimeter installation Type VFC-2/F/Z, for extremely low inlet temperatures Specification Dimensions, weights Fan coil unit with one heat exchanger for heating or cooling the ambient air. Water-side control by valves. Particularly small built-in depth and height, therefore especially appropriate for a room-saving perimeter installation. For extremely low inlet temperatures an insulated drain tray is available for insertion on site. Vertical installation. Water connection on the right or left. * approx. values, depending on...

Open the catalog to page 11

All LTG Aktiengesellschaft catalogs and technical brochures

  1. Silencers

    10 Pages

Archived catalogs