Product catalog summary
Overview: The document provides comprehensive technical specifications and installation guidelines for LTG Aktiengesellschaft's decentralized facade ventilation units, specifically the Univentr Type FVS series. These units are designed for indoor installation below the ceiling, suitable for environments such as conference rooms and schools.
Specifications: The FVS units are compact air conditioning systems that facilitate decentralized ventilation directly via the facade. They include components such as a weather protection grille, ventilation module with sound and heat insulation, supply and exhaust air fans, and a heat recovery system. The units are designed to accommodate 20 to 30 people in a ventilated area of 60 to 80 m².
Advantages: Key benefits include a compact design, easy installation, high thermal comfort, energy-efficient operation, and high sanitation standards. The units offer high outside air flow rates and low sound pressure levels, with efficient heat recovery up to 85%.
Functional Principle: The units connect to an outside air module with a weather protection grille, facilitating the separation of exit and outside air streams. They feature a combined outside air/secondary air damper for efficient air mixing and temperature control, ensuring energy-efficient heating and cooling.
Installation: The units can be installed visibly below the ceiling or integrated into ceiling paneling. They require specific installation dimensions and configurations, including the use of linear or swirl diffusers for air distribution.
Design and Standards: The units meet various DIN standards for dimensions, tolerances, and surface finishes. They are designed for indoor air climate applications and are powder-coated for durability.
Control and Operation: The units feature electronic controls for start-up and shut-down, supply air temperature control, and usage-dependent ventilation. They can be operated manually or via sensors and are compatible with building management systems.
Technical Data: Detailed sound power levels (LwA) for different operating modes and configurations are provided, including the use of a splitter attenuator. Power consumption (Pel) is specified for various modes. The sound power levels are measured at different points, such as the sound absorber outlet and the weather protection grille.
Control System: The FVS units feature a convenience control type DKR 6000, optimized for energy consumption and indoor air quality. The control system includes automatic mode activation based on CO2 levels, with inputs for different ventilation modes (100%, 50%, nocturnal, and forced ventilation). The system is factory-programmed and includes a CO2 sensor for automatic operation.
Installation Requirements: The document outlines the installation requirements, including the integration of the weather protection grille, adapter ducts, and inspection openings. It emphasizes the importance of air-tight separation of outside and exit air ducts and provides guidelines for connecting the unit to the facade.
Additional Features: The units include a condensate drainage system, emergency shutoff mechanisms, and malfunction indicators. The control system allows for parametrization via an optional HMI module, enabling adjustments to operating modes and set-points.
Conclusion: The LTG Decentralized Facade Ventilation Units Univentr Type FVS-S are designed for efficient and flexible ventilation solutions, with detailed specifications and control options to optimize performance and energy efficiency.
General Description: The document describes a decentralized facade ventilation unit, Univent® Type FVS-S/O, designed for visible installation with an integrated linear diffuser. It features high-efficiency sound absorption for supply and exhaust air, direct facade connection, and weather protection grilles. The unit supports decentralized ventilation with heat recovery and controllable secondary air mode, maintaining a minimum supply air temperature of 17°C year-round.
Specifications: The unit includes a twin-wall casing of galvanized sheet steel with 40 mm mineral wool insulation. It is designed for free cooling through supply air temperature control and features low-noise centrifugal fans with energy-efficient EC motors. The unit meets SFP Class 1 requirements and includes fine filters for outside and exhaust air.
Control and Operation: The control system is integrated, offering four operating modes and potential-free contact switching. It includes supply air temperature control to prevent freezing and supports nocturnal ventilation. The system can connect to an air cooler and features an Ethernet interface for parameter adjustments.
Installation and Maintenance: The unit is suitable for plug-in installation in school rooms, with easy connection to the outer wall. It is factory-wired and tested, with a modular design for flexibility. Maintenance access is provided for filters, actuators, and condensate trays.
Dimensions and Accessories: The unit measures 500 mm in height, 1050 mm in width, and 4500 mm in length. Accessories include service tools, remote switching units, duct adapters, CO2 sensors, and interfaces for control overriding. The document emphasizes the need for proper electrical installation verification before commissioning.
See more

Catalog excerpts

Facade fancoil unit FVS-1

Technical Documentation Decentralized Facade Ventilation Units Univentr Type FVS For installation below the ceiling LTG Aktiengesellschaft D - 70435 Stuttgart, Grenzstraße 7 +49 (711) 82 01-0, Fax +49 (711) 82 01-720 Internet: www.LTG-AG.de E-Mail: [email protected] LTG Incorporated 105 Corporate Drive, Suite E Spartanburg S.C., 29303 USA +1 (864) 599-6340, Fax +1 (864) 599-6344 Internet: www.LTG-INC.net E-Mail: [email protected]

 Open the catalog to page 1
Facade fancoil unit FVS-2

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univent® Type FVS Content Application, positioning, product overview, equipment configuration, design Advantages, functional principle Air conveyance via the facade, specification Details type FVS-DI/LDB Details type FVS-S Notes Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Tolerances according to DIN ISO 2768-vL. For the outlet grille special tolerances stated in the drawing apply. Straightness and twist tolerances for extruded aluminum profiles according...

 Open the catalog to page 2
Facade fancoil unit FVS-3

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS The decentralized facade ventilation units type FVS are compact A/C units for installation indoors. Application, positioning Decentralized ventilation (air supply and return) of single rooms directly via the facade, including heat recovery, heating/cooling optional. Particularly suitable for conference rooms and schools with high acoustic requirements. Designed for an average of 20 to 30 people and a ventilated area of 60 to 80 m2. Installation visible below the ceiling or as part of the...

 Open the catalog to page 3
Facade fancoil unit FVS-4

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS Advantages Compact design with easy connection to the facade, airtight outside air damper, and excellent heat and sound insulation (insulating case 40 mm) Quick and easy installation, in case of retrofitting minimum disturbance of ongoing operations High thermal comfort due to high-quality air conveyance system for speedy reduction of temperature differences and indoor air velocities On/off via CO2 sensor, motion detector optional, manual control, GLT; ventilation level changeover (optional,...

 Open the catalog to page 4
Facade fancoil unit FVS-5

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS A compact, high-efficiency twin sound absorber insulates the unit to the room. The sound absorber's exhaust air line is connected to an exhaust air grille, which may be provided with a coarse dust filter (optional, on site). Dimensions weather protection grille 35 Front view Air conveyance via the facade The weather protection grille has been aerodynamically optimized for FVS operation and is included in the delivery. The exit air is diffused with an angle of 45° away from the facade which...

 Open the catalog to page 5
Facade fancoil unit FVS-6

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS-DI/LDB The type FVS-DI/LDB is suitable for integration in ceiling panelings (to be provided on site) usually between the facade and the corridor wall. The ceiling cavity in its function as supply air plenum is to be air tight and has to be applied a minor overpressure of 5 - 10 Pa. The inspection openings should be distributed as shown in the drawing. Avoid any bars underneath the medium cover in order not to impede the heat recoverer’s removal. For supply air diffusion use linear diffusers...

 Open the catalog to page 6
Facade fancoil unit FVS-7

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS-DI/LDB Connections to the sound absorber end Depending on the type of connection, the following options are available: Return air/supply air connecting duct (variants see below) Supply air Sound absorber Inspection cover Connecting duct variants Supply air Exhaust air Exhaust air Exhaust air Mat.-Nr:1042555 Free blow of supply air E LTG Aktiengesellschaft Grenzstraße 7 D-70435 Stuttgart +49 (711) 8201-0 Fax -720 Internet: www.LTG-AG.de E-Mail: [email protected] Printed in Germany · Former...

 Open the catalog to page 7
Facade fancoil unit FVS-8

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS-S Ready-to-install decentralized facade ventilation unit for installation below the ceiling, suitable for visible assembly without additional ceiling paneling. With high-efficiency sound absorber for supply and exhaust air and with direct connection to the facade including outside/exit air openings and weather protection grille with aerodynamic separation of supply and exhaust air conduction. For decentralized ventilation (supply and return) directly via the facade. Dimensions type FVS-S...

 Open the catalog to page 8
Facade fancoil unit FVS-9

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS-S Installation (visible) Exhaust air box Outlet air box, right side Outlet sound absorber, right side Sound absorber Outlet unit, right side FVS unit E LTG Aktiengesellschaft Grenzstraße 7 D-70435 Stuttgart +49 (711) 8201-0 Fax -720 Internet: www.LTG-AG.de E-Mail: [email protected] Printed in Germany · Former editions are invalid · Subject to technical modifications

 Open the catalog to page 9
Facade fancoil unit FVS-10

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS Control Technical Data Operating mode Controller operational mode 50 % LwA,3 [dB(A)] with 500 mm splitter attenuator LwA,1 Sound power level of radiated noise at the sound absorber outlet for supply air and exhaust air, with 3 dB absorption via diffusers LwA,2 Sound power level of emission via casing, 3 dB sound absorption via ceiling paneling Note: not applicable for visible installed units LwA,3 Sound power level on the outside at the weather protection grille for outside air and exit...

 Open the catalog to page 10
Facade fancoil unit FVS-11

The Innovation Company LTG Aktiengesellschaft LTG Decentralized Facade Ventilation Units Univentr Type FVS Control Other modes on site: - Decentralized via button Manual on/off switch, selection of mode level; prolonged operating times due to „not switching off“ may be avoided by fixed operating times or central, scheduled cutoffs; after switching off a ventilation follow-up time is recommended to provide initial air quality. In schools, unauthorized manipulation must be avoided. It might not be possible to protect operating units against vandalism. - Central activation of fixed & scheduled operating...

 Open the catalog to page 11