Catalog excerpts
Facade Fan Coil Unit Type A/C System FVM For Facade Installation LTG Aktiengesellschaft D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-0, Fax +49 (0711) 82 01-720 Internet: http://www.LTG-AG.de E-Mail: info@LTG- AG.de - LTG Incorporated 105 Corporate Drive, Suite E Spartanburg S.C., 29303 USA +1 (864) 599- 6340, Fax +1 (864) 599- 6344 Internet: http://www.LTG-INC.net E-Mail: info@LTG- INC.net -
Open the catalog to page 1Components for Room Air Technology Germany Central Office (Frankfurt) Sales area: PLZ 54, 55, 60, 63, 64, 66-69, 97 Sontraer Str. 27 D-60386 Frankfurt am Main (069) 94 20 19-14, Fax -10 E-mail: Bergmann@LTG-AG.de Central office (Herborn) Sales area: PLZ 30, 31, 34-38, 56, 57, 61, 65 Sperberweg 16 D-35745 Herborn Herr Hartmann (02772) 570-725, Fax -727 E-mail: Hartmann@LTG-AG.de Eastern office (Berlin) Sales area: PLZ 10-25, 29, 39 Eisenhutweg 51a D-12487 Berlin Herr Linke (030) 63 22 87-74, Fax -75 E-mail: Linke@LTG-AG.de Eastern office (Chemnitz) Sales area: PLZ 01-09, 98, 99...
Open the catalog to page 2Facade Fan Coil Unit Type A/C System FVM for Decentralized Ventilation with Outside Air via the Facade and for Heating and Cooling Application Decentralized modular A/C system, flush mounted in a single- shell facade, for decentralized ventilation of occupied rooms via the facade using outside air, as well as for heating and cooling. All functions integrated in one ready- to- install unit. - - Functions - Ventilation (air diffusion + return) - Outside air filtering F7 - Heating and cooling in the outside air and recirculating air mode - Heat and humidity recovery WFRG (heat and humidity...
Open the catalog to page 3Facade Fan Coil Unit Type A/C System FVM Advantages Minimum space requirement even when installed in single- shell facades: width: 450 mm, depth: 160 mm, height: 2680 mm. Maximum space efficiency due to savings in floor height, shaft surfaces, and technician rooms. Modular construction, extendable in steps from static heating to air conditioning, therefore - no unnecessary preparation costs - easy retrofitting - unlimited tenant/user flexibility High user acceptance due to individual operability. Complete, discrete integration in the facade - due to low unit depth and with - due to flush...
Open the catalog to page 4Facade Fan Coil Unit Type A/C System FVM Connection to the facade (example) High-vacuum panel (facade) Glazing (facade) Vapor barrier on site Insulation (facade) Facade air opening with protection against wind-driven rain and drainage to the outside Insulating strips, installation on site Outside air damper Exhaust air damper Cellular rubber strip (seal) EPDM seal Seal (VDI approved) on site Facade vacuum panel Internal face covering / appearance (examples) Aerodynamic slot 5 mm front panel Flush installation between posts 24 Visible slot Heat exchanger 5 mm front panel Flush installation...
Open the catalog to page 5Facade Fan Coil Unit Type A/C System FVM 450 +3 without screw heads Protection against accidental contact secondary air fan *Dimensions may vary depending on the project Cable feed- through - EPDM- plate - ca. 170 including measuring sensor Insulating strips towards the facade 450 +3 66 250 li 450 +3 Cellular rubber strips Insulating strips towards the facade E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-0 Fax -720 Internet: http://www.LTG-AG.de ⋅ E-Mail: info@LTG-AG.de ⋅ Printed in Germany Former editions are invalid ⋅ Subject to technical modifications.
Open the catalog to page 6Facade Fan Coil Unit Type A/C System FVM Technical Specifications Functions: Outside air/return air mode, Recirculating air mode, Cooling and Heating, Heat and Humidity Recovery (WFRG) Recirculating air only nA1 wok/pw [kg/h]/[kPa] = 120/10 woh/pw [kg/h]/[kPa] = 100/3 Supply voltage 230 V AC Power consumption ca. 100 VA Weight abt. 75 kg Depending on the type of unit casing the performance loss may be e.g. 10% 1 Fresh air 2 Secondary air 3 Outside air flow rate 4 Secondary air flow rate by induction + secondary air flow rate from recirculating air fan (- 10%) 5 Water supply temperature: 17...
Open the catalog to page 7Facade Fan Coil Unit Type A/C System FVM Due to the many parameters decisive for a decentralized unit’s output we will state one example only. Further dimensioning on request using a specific program. Example for: Type Outside air flow rate Room temperature Water intake temperature Nominal water volume Speed outside air and exhaust air fan Speed secondary air fan Heat and humidity recovery Overall cooling capacity with different water flow rates 550 525 Flow rate in % of the nominal flow rate Wasserseitiger Druckverlust pw [kPa] Cooling capacity Qk [W] Room-effective cooling capacity with...
Open the catalog to page 8Facade Fan Coil Unit Type A/C System FVM Control Frost Protection When integrating the A/C system type FVM into a closed- loop control circuit the following particuliarities will have to be considered: In the decentralized A/C system type FVM, both outside air and room air are routed through the heat exchanger. As outside air temperature variations can be significantly higher than intake temperatures in standard recirculating air units, standard fan coil unit control strategies cannot be used without making certain modifications. Since the heat exchanger in decentralized A/C units can...
Open the catalog to page 9Facade Fan Coil Unit Type A/C System FVM Comfort Control Type DKR 5000 Comfort controller in connecting box for installation in window sills or false floors as stand- alone system or integrated in a bus system (LON/KNX) Type DKR 5000 in a protection class IP 45 casing to be connected to the FVM unit s cable harness, voltage supply (24 V), grounding, connection to the operating unit, connection to LON bus or to the neighboring unit in the same room. Digital controller with the following functions: - PI room temperature controller for heating/cooling with separate setting of P and I shares to...
Open the catalog to page 10Facade Fan Coil Unit Type A/C System FVM Comfort Control Type DKR 5000 Technical data operating unit: Power supply Operating Unit The operating unit QAA 88.3 with LCD display is connected to the individual room controller via PPS2 interface. It offers the following functions: - Digital operating unit with temperature sensor, operating keys and display, connected to the controller via PPS2 bus (no LON/KNX) - 3K room temperature set point adjuster - Presence key to switch from pre- comfort to comfort set point Alternatively, any LON- compatible operating unit may be used. Functions and key...
Open the catalog to page 11All LTG Aktiengesellschaft catalogs and technical brochures
-
LTG Centrifugal Separators
10 Pages
-
LTG Fibre Compactor
14 Pages
-
LTG Air Distribution
16 Pages
-
LTG Air-Water Systems
32 Pages
-
Product Overview Air Diffusers
28 Pages
-
Swirl Diffusers Type DLA
28 Pages
-
LTG cool wave®
53 Pages
-
Fancoil Units floor mounted
39 Pages
-
Facade fancoil unit FVD
35 Pages
-
Facade fancoil unit FVS
24 Pages
-
Flow-Rate Controller Type VRE-W
14 Pages
-
Flow-Rate Controller Type VRF-W
16 Pages
-
Flow-Rate Controller Type VRD-W
16 Pages
-
Silencers
10 Pages