1. Catalogs
  2. LSP
  3. SLP40-DCxxx/2(S)

SLP40-DCxxx/2(S)

SLP40-DCxxx/2(S)

SLP40-DCxxx/2(S)

Product catalog summary
Overview: The document provides technical specifications and details for the SLP40-DCxxx/2(S) DC Surge Protective Device, designed for use in string boxes and inverters. It outlines the device's protective features, compliance standards, and mechanical and environmental specifications.
Specifications: The device uses high energy MOVs for protection and features a pluggable design. It complies with IEC/EN Category Class II / Type 2 standards. The nominal discharge current is 40 kA, with a maximum discharge current of 40 kA. The voltage protection level is specified for various configurations, and the response time is less than 25 ns.
Mechanical & Environmental: The device operates within a temperature range of -40 ºF to +158 ºF (-40 ºC to +70 ºC) and a humidity range of 5% to 95%. It is mounted on a 35 mm DIN Rail and has an IP 20 degree of protection. The housing is made of thermoplastic with an extinguishing degree of UL 94V-0.
Additional Features: The device includes thermal protection and state/fault indication with green for OK and red for defect. Remote contacts are optional, with specific switching capacities and conductor cross sections.
Order Information: Various ordering codes are provided for different configurations, including spare modules and units with remote contacts.
Dimensions & Packaging: The document includes dimensions for the complete unit, spare plug, and single unit, along with packaging dimensions and standard order quantities.
See more

Catalog excerpts

SLP40-DCxxx/2(S)-1

DC Surge Protective Ddevice Location of Use: Mode of Protection: Surge Ratings: IEC/EN Category: Protective Elements: ITotai= 40kA (8/20 ps) Class II / Type 2 High Energy MOV Pluggable Design IEC/EN 61643-41 Technical Data Rated Operational DC Voltage Maximum Continuous Operating DC Voltage (DC+) - PE, (DC-) - PE Nominal Discharge Current (8/20 ps) Total Discharge Current (8/20 ps) Maximum Discharge Current (8/20 ps) Voltage Protection Level Response Time Mechanical & Environmental 2 AWG (Solid, Stranded) / 4 AWG (Flexible) Operating Temperature Range Ta Permissible Operating Humidity RH Atmospheric pressure and altitude Terminal Screw Torque Mmax Conductor Cross Section (max) Degree Of Protection Housing Material Thermal Protection Thermoplastic: Extinguishing Degree UL 94V-0 Yes Operating State / Fault Indication Remote Contacts (RC) RC Switching Capacity RC Conductor Cross Section (max) Order Information SLP40-DCxxx/2S (with remote contacts) SLP40-DCxxx/0 (spare modules) Green ok / Red defect Optional 85 Low Voltage Power Systems Series

 Open the catalog to page 1
SLP40-DCxxx/2(S)-2

Internal Configuration Legend @/PE PE/G Conductor Terminal S Signalling Contacts Optional Complete Unit Standard Order Quantity 48 Units Single Unit Standard Order Quantity 120 Units Pluggable Single & Multi-pole SPDs J 86

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.