Product catalog summary
Introduction
Lowara, a part of Xylem Inc., is a leading supplier of pump technology, offering solutions for both commercial and residential applications. This document provides an overview of Lowara's Variable Speed Booster Sets, emphasizing their reliability and efficiency across various environments.
Booster Set Characteristics
Lowara's booster sets are compact and cost-effective, suitable for applications ranging from small domestic premises to large complexes. They feature robust control systems to manage power fluctuations and comply with EC directives for EMC emissions and immunity.
Pump Configuration
Hydrovar sets are available in configurations such as single pump, duty assist, and duty standby. TKS sets can be configured as single or twin pump sets.
Installation and Service
Each booster set is fully packaged with isolating valves, non-return valves, and pressure sensors. Pressure vessels are typically supplied separately for ease of shipping.
Booster Set Selection
Selection involves determining the maximum probable simultaneous demand and the required flow rate and head. Systems can be configured with multiple pumps to share the duty and ensure reliability.
Assessment of Probable Demand
The demand is assessed using loading unit values, considering the type of building and appliances. A working example is provided to illustrate the calculation of total flow.
Assessing Head Requirement
The total head required includes static head, residual pressure, and system friction losses. An example calculation is provided to demonstrate the process.
Noise Emission Levels
Noise levels for various models are detailed, with most models maintaining noise levels below 70 dB.
GTKS Series Specifications
The GTKS series offers single and twin booster sets with delivery up to 16 m3/h and head up to 70 m. They feature stainless steel pumps and manifolds, designed for easy installation and servicing.
Special Versions
Special versions with different materials and additional functions are available upon request.
Specifications
The GTKS series includes various pump types with different rated powers and delivery capacities. The GHV series booster sets can accommodate up to four pumps with a maximum delivery of 400 m3/h and a head of up to 150 meters. Input voltage options include single-phase and three-phase.
Materials
The pumps and manifolds are primarily made of stainless steel, with options for AISI 304 and AISI 316 for special applications. Nickel-plated brass and other materials are used for various components.
Performance Tables
Extensive hydraulic performance tables for different pump series (e.g., 1SV, 3SV, 5SV, 10SV, 15SV, 22SV, 33SV, 46SV) at 50 Hz are included, detailing delivery rates and total head in meters of water column.
Dimensional Details
Detailed dimensions for both horizontal and vertical pumps are provided, including connection sizes and weights.
Applications
The pumps are suitable for water supply in residential, commercial, and agricultural settings. The GHV series is noted for its compact design, ideal for limited space installations.
Control and Features
The GHV series includes Hydrovar frequency converters and various control features for efficient operation. The document outlines the main components, including manifolds, valves, and control panels, with specific details on their construction and functionality.
Special Versions and Options
Special versions with different materials and additional functions are available, as well as options for pressure switches and sensors.
Procedures and Recommendations
The document emphasizes the importance of using booster sets to overcome low water pressures, especially in residential settings. It highlights the energy savings and stable pressure platform provided by the Resvari variable speed booster set. Recommendations include ensuring sufficient water storage to cover peak demands and interruptions in supply.
Company Information
Xylem Applied Water Systems is highlighted as a leader in water technology, focusing on innovative solutions for water management. Contact information for Lowara UK Limited and Xylem Water Solutions Ireland Limited is provided for further inquiries.
See more

Catalog excerpts

Lowara UK Variable Speed Booster sets-2

Your trusted partner The professionals in pump technology across all building services Lowara is a leading supplier of pump technology to the building services industry. Thousands of commercial and residential applications rely on our pumps, day in day out. Lowara is globally recognised for its quality in pumping products and services, from consultation to implementation. This brochure will give you an overview of our specialised Variable Speed Booster Set pumps range. Please contact us for detailed technical specications and quality standards. Find out more on www.lowara.co.uk

 Open the catalog to page 2
Lowara UK Variable Speed Booster sets-3

Booster Set main characteristics Assessment of probable demand Electrical Data and Noise emissions Levels Resvari Variable Speed Booster Set Mini VH and W Variable Speed Booster Set

 Open the catalog to page 3
Lowara UK Variable Speed Booster sets-4

Lowara training...the way forward CIBSE accredited courses One or two hour CPD seminars, at the clients premises, half and full day training can be arranged at company HQ in Axminster, Devon or at any location in the UK. All courses cover the pumps, systems and variable speed drives. Lowara also offer HVAC application training, all are taught by experts in the field and comprehensive course notes are provided. LTC - in-house training, seminars, and With our Lowara Training Centre we provide a learning environment that promotes the transfer of new skills and knowledge to the work setting through...

 Open the catalog to page 4
Lowara UK Variable Speed Booster sets-5

VARIABLE SPEED BOOSTER SETS Wide range of 1, 2, 3 and 4 pump variable speed booster sets with individual transducers for each pump giving a very robust operating system. APPLICATIONS • Water supply to domestic dwelling and ofce buildings, hotels, shopping centers, factories, and greenhouses. • Water supply for agricultural use (irrigation systems). • Water supply to systems requiring constant pressure. GTKS MULTISTAGE INTRODUCTION Lowara booster sets have been designed to be both compact and cost effective. Both the TKS and Hydrovar range are built to exacting standards and as such are suitable...

 Open the catalog to page 5
Lowara UK Variable Speed Booster sets-6

INSTALLATION AND SERVICE Each set comes fully packaged complete with isolating valves, non return valves (Anti-vibration feet), and pressures sensors. Small sets are provided with screwed manifolds whilst all other sets are provided with anged manifolds. Pressure vessels are normally supplied separate from the base to keep the pump set size to a minimum for ease of shipping and manoeuvrability, however vessels can be integrated into the pump set when required. All pumps can easily be removed for servicing. PUMPS Lowara have been manufacturing a large range of high quality end suction and vertical...

 Open the catalog to page 6
Lowara UK Variable Speed Booster sets-7

MAIN CHARACTERISTICS OF ELECTRIC PUMPS USED IN GTKS AND GHV BOOSTER SETS CEA, CEAM, CA, CAM Close-coupled, threaded centrifugal electric pumps, single impeller (CEA) and twin-impeller type (CA). Stainless steel pump body, seal housing, impeller and diffuser. Continuous duty, enclosed IE2 motor with external ventilation and nned casing made of aluminium alloy. HM Multi-stage centrifugal horizontal electric pumps with power up to 0.9 kW. Stainless steel pump body, seal housing and diffuser. Impellers made of technopolymer. Continuous duty, enclosed IE2 motor with external ventilation and nned casing...

 Open the catalog to page 7
Lowara UK Variable Speed Booster sets-8

SELECTING A SET The rst thing to do when selecting a set is to determine the volume of water required and the pressure it must produce. CALCULATING THE FLOW RATE • The volume of water called water requirement depends on the type of users, e.g. homes, ofces, schools, as well as their number. The theoretical requirement is the total volume of water required by all the users. In actual fact, since it is very unlikely that there should be a simultaneous demand by all the users, the real requirement is lower than the theoretic one. CALCULATING THE HEAD • The pressure required depends on the type of...

 Open the catalog to page 8
Lowara UK Variable Speed Booster sets-9

ASSESSMENT OF PROBABLE DEMAND The method adopted is based on loading unit values as detailed in the Plumbing Engineering Design Guide published by the Institute of Plumbing. When designing a hot or cold water supply system an assessment must be made to obtain the maximum probable simultaneous demand. Depending on the type of services being provided it rarely occurs for all the appliances to be used at the same time therefore the design usually allows for a peak usage which is less than the maximum. Probable demand will depend on, the type of building and its use, type of appliances installed...

 Open the catalog to page 9
Lowara UK Variable Speed Booster sets-10

ASSESSING HEAD REQUIREMENT The head required in a boosted cold water system consists of three components, static head, residual pressure and system friction losses. The values of these three components are added together to give the total required head at the system ow rate. Static head (He): This is the difference between the break tank low water line and the highest discharge point in the building. If the height of the build is not known, then 2.83.0 metres per oor can be used to assess the building height. Residual pressure (Hr): This is the pressure required at the highest outlet device,...

 Open the catalog to page 10
Lowara UK Variable Speed Booster sets-11

GHV/GTKS 10/20/30/40 ELECTRICAL DATA NOMINAL POWER 1 PUMP GTKS 10 GTKS 20 GHV10../M GHV20../M GHV10 GHV20 GHV30 GHV40 ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED CURRENT 1 X CURRENT 1 X CURRENT 1 X CURRENT 1 X CURRENT 3 X CURRENT 3 X CURRENT 3 X CURRENT 3 X 230V 230V 230V 230 V 400V 400V 400V 400V NOISE EMISSION LEVELS 50 Hz 2900 min -1 LpA (dB +/-2) Electric motor only R = Reduced motor casing

 Open the catalog to page 11
Lowara UK Variable Speed Booster sets-12

GTKS SERIES SINGLE AND TWIN BOOSTER SET Single-phase variable-speed pressure boosters with pressure transducer control. CA, CEA, HM and e-SV versions available. SPECIFICATIONS Number of pumps: 1 or 2 Delivery: up to 16 m3/h Head: up to 70 m Electric supply panel voltage: 1 x 230 V 50 Hz (single-phase) Power: 1 or 2 x 1.1 kW Motor starting: variable frequency operation Temperature of pumped liquid: C SETS: 0°C to +85°C HM SETS: 0°C to +60°C SV SETS: 0°C to +80°C Pump type: horizontal and vertical PRODUCT FEATURES • Easy to install. • Trouble-free servicing. • Pressure transducer control (one per...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.