video corpo cad

Lowara UK Variable Speed Booster sets
96Pages

{{requestButtons}}

Catalog excerpts

Lowara UK Variable Speed Booster sets - 1

Speed Booster Sets

Open the catalog to page 1
Lowara UK Variable Speed Booster sets - 2

Your trusted partner The professionals in pump technology across all building services Lowara is a leading supplier of pump technology to the building services industry. Thousands of commercial and residential applications rely on our pumps, day in day out. Lowara is globally recognised for its quality in pumping products and services, from consultation to implementation. This brochure will give you an overview of our specialised Variable Speed Booster Set pumps range. Please contact us for detailed technical specications and quality standards. Find out more on www.lowara.co.uk

Open the catalog to page 2
Lowara UK Variable Speed Booster sets - 3

Booster Set main characteristics Assessment of probable demand Electrical Data and Noise emissions Levels Resvari Variable Speed Booster Set Mini VH and W Variable Speed Booster Set

Open the catalog to page 3
Lowara UK Variable Speed Booster sets - 4

Lowara training...the way forward CIBSE accredited courses One or two hour CPD seminars, at the clients premises, half and full day training can be arranged at company HQ in Axminster, Devon or at any location in the UK. All courses cover the pumps, systems and variable speed drives. Lowara also offer HVAC application training, all are taught by experts in the field and comprehensive course notes are provided. LTC - in-house training, seminars, and With our Lowara Training Centre we provide a learning environment that promotes the transfer of new skills and knowledge to the work setting...

Open the catalog to page 4
Lowara UK Variable Speed Booster sets - 5

VARIABLE SPEED BOOSTER SETS Wide range of 1, 2, 3 and 4 pump variable speed booster sets with individual transducers for each pump giving a very robust operating system. APPLICATIONS • Water supply to domestic dwelling and ofce buildings, hotels, shopping centers, factories, and greenhouses. • Water supply for agricultural use (irrigation systems). • Water supply to systems requiring constant pressure. GTKS MULTISTAGE INTRODUCTION Lowara booster sets have been designed to be both compact and cost effective. Both the TKS and Hydrovar range are built to exacting standards and as such are...

Open the catalog to page 5
Lowara UK Variable Speed Booster sets - 6

INSTALLATION AND SERVICE Each set comes fully packaged complete with isolating valves, non return valves (Anti-vibration feet), and pressures sensors. Small sets are provided with screwed manifolds whilst all other sets are provided with anged manifolds. Pressure vessels are normally supplied separate from the base to keep the pump set size to a minimum for ease of shipping and manoeuvrability, however vessels can be integrated into the pump set when required. All pumps can easily be removed for servicing. PUMPS Lowara have been manufacturing a large range of high quality end suction and...

Open the catalog to page 6
Lowara UK Variable Speed Booster sets - 7

MAIN CHARACTERISTICS OF ELECTRIC PUMPS USED IN GTKS AND GHV BOOSTER SETS CEA, CEAM, CA, CAM Close-coupled, threaded centrifugal electric pumps, single impeller (CEA) and twin-impeller type (CA). Stainless steel pump body, seal housing, impeller and diffuser. Continuous duty, enclosed IE2 motor with external ventilation and nned casing made of aluminium alloy. HM Multi-stage centrifugal horizontal electric pumps with power up to 0.9 kW. Stainless steel pump body, seal housing and diffuser. Impellers made of technopolymer. Continuous duty, enclosed IE2 motor with external ventilation and nned...

Open the catalog to page 7
Lowara UK Variable Speed Booster sets - 8

SELECTING A SET The rst thing to do when selecting a set is to determine the volume of water required and the pressure it must produce. CALCULATING THE FLOW RATE • The volume of water called water requirement depends on the type of users, e.g. homes, ofces, schools, as well as their number. The theoretical requirement is the total volume of water required by all the users. In actual fact, since it is very unlikely that there should be a simultaneous demand by all the users, the real requirement is lower than the theoretic one. CALCULATING THE HEAD • The pressure required depends on the type...

Open the catalog to page 8
Lowara UK Variable Speed Booster sets - 9

ASSESSMENT OF PROBABLE DEMAND The method adopted is based on loading unit values as detailed in the Plumbing Engineering Design Guide published by the Institute of Plumbing. When designing a hot or cold water supply system an assessment must be made to obtain the maximum probable simultaneous demand. Depending on the type of services being provided it rarely occurs for all the appliances to be used at the same time therefore the design usually allows for a peak usage which is less than the maximum. Probable demand will depend on, the type of building and its use, type of appliances...

Open the catalog to page 9
Lowara UK Variable Speed Booster sets - 10

ASSESSING HEAD REQUIREMENT The head required in a boosted cold water system consists of three components, static head, residual pressure and system friction losses. The values of these three components are added together to give the total required head at the system ow rate. Static head (He): This is the difference between the break tank low water line and the highest discharge point in the building. If the height of the build is not known, then 2.83.0 metres per oor can be used to assess the building height. Residual pressure (Hr): This is the pressure required at the highest outlet...

Open the catalog to page 10
Lowara UK Variable Speed Booster sets - 11

GHV/GTKS 10/20/30/40 ELECTRICAL DATA NOMINAL POWER 1 PUMP GTKS 10 GTKS 20 GHV10../M GHV20../M GHV10 GHV20 GHV30 GHV40 ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED ABSORBED CURRENT 1 X CURRENT 1 X CURRENT 1 X CURRENT 1 X CURRENT 3 X CURRENT 3 X CURRENT 3 X CURRENT 3 X 230V 230V 230V 230 V 400V 400V 400V 400V NOISE EMISSION LEVELS 50 Hz 2900 min -1 LpA (dB +/-2) Electric motor only R = Reduced motor casing

Open the catalog to page 11
Lowara UK Variable Speed Booster sets - 12

GTKS SERIES SINGLE AND TWIN BOOSTER SET Single-phase variable-speed pressure boosters with pressure transducer control. CA, CEA, HM and e-SV versions available. SPECIFICATIONS Number of pumps: 1 or 2 Delivery: up to 16 m3/h Head: up to 70 m Electric supply panel voltage: 1 x 230 V 50 Hz (single-phase) Power: 1 or 2 x 1.1 kW Motor starting: variable frequency operation Temperature of pumped liquid: C SETS: 0°C to +85°C HM SETS: 0°C to +60°C SV SETS: 0°C to +80°C Pump type: horizontal and vertical PRODUCT FEATURES • Easy to install. • Trouble-free servicing. • Pressure transducer control (one...

Open the catalog to page 12

All LOWARA catalogs and technical brochures

  1. CO-SHO Series

    104 Pages

  2. Lowara e-SH

    4 Pages

  3. CO Series

    20 Pages

  4. GEM leaflet

    3 Pages

  5. ecocirc PRO

    5 Pages

  6. e-Range 50Hz

    28 Pages

  7. e-NSC

    4 Pages

  8. RainPerfect

    2 Pages

  9. GENYO

    8 Pages

  10. Floodkit

    2 Pages

  11. e SV

    4 Pages

  12. DDC Pump

    4 Pages

  13. Aquontroller

    2 Pages

  14. Aquada UV

    2 Pages

  15. AquaCharge

    2 Pages

  16. AG JEC

    4 Pages

  17. e-HM

    7 Pages

  18. SCUBA, GS

    92 Pages

  19. ECOCIRC

    8 Pages

  20. FC-FCT

    45 Pages

  21. SVI - 50 Hz

    56 Pages

  22. e-SV

    4 Pages

  23. BG series

    3 Pages

  24. SP series

    3 Pages

  25. CO - 60 Hz

    20 Pages

Archived catalogs