WORKING CLEAN, BREATHING HEALTHY Losma / Liquid filters Master + MedioMaster + MiniMaster Liquid filters Hydrostatic TNT coolant filtration system
Open the catalog to page 1MASTER is a range of high efficiency gravity filters, using non-woven fabric as filter media. Master series is available in 4 models, able to manage flowrates from 200 to 1000 l/min of neat oil and from 400 to 2000 l/min of water based emulsion, contaminated by metallic or non-metallic Losma grants that every single system is tested through strict control procedures. Every unit is provided with a Quality and Functional Test Certificate. particles. Master’s operation is simple and its efficiency is stable and constant. This type of filter is suitable for cooling and lubricant liquids used in...
Open the catalog to page 2Technical Data Master Tank Tank with Capacity tissue Master Flow [l/min] Washing machines, Drawbench chip removal machines (emulsion) (emulsions) Grinding (emulsion)
Open the catalog to page 3MEDIO–MASTER is a high efficiency industrial coolant filtration system, available in 3 models able to treat from 150 to 200 l/min of neat oil and from 400 to 800 l/min of water based emulsion, contaminated by metallic and non-metallic particles. Losma grants that every single system is tested through strict control procedures. Every unit is provided with a Quality and Functional Test Certificate. Medio – Master grants very high coolant filtration levels based on customer’s needs, thanks to the consumable filter media. It is used in many industrial processes, such as: drawing, milling,...
Open the catalog to page 4Technical Data Medio Master Dimensions [mm] Models Filter positioning Standard tank dimensions Tank Capacity Weight Weight Tank filter only Tissue width Medio Master Flow [l/min] Models Medio 600 Medio 800 Medio 1200 Grinding (emulsion) Drawbench (emulsion) from 400 to 600 from 600 to 800 from 800 to 1200 Washing machines, chip removal machines (emulsions) 600 800 1200
Open the catalog to page 5MINI–MASTER series is composed of 3 models, able to filter from 60 to 200 l/min of neat oil and from 100 to 400 l/min of water based emulsion, contaminated by metallic and non-metallic particles. Mini-Master has an optimum filtration level, thanks to Losma grants that every single system is tested through strict control procedures. Every unit is provided with a Quality and Functional Test Certificate. the consumable filter media, which can be selected according to customer needs. Its dimensions are significantly smaller and is used in many industrial processes, such as: drawing, milling,...
Open the catalog to page 6Technical Data Mini Master Tank Capacity Tank with tissue Mini Master Flow [l/min] Models Grinding (emulsion) Washing machines, Drawbench chip removal machines (emulsion) (emulsions)
Open the catalog to page 7Working Principles 1. The filter fabric is perfectly clean; the dirty liquid begins depositing the pollutant on the fabrics surface. The clean liquid goes through the lower part where the discharge opening is located and falls into the tank underneath. During this phase the system is idle and the filter carpet is not advancing. The pollutant which is deposited on the filter fabric forms the actual filtering layer. In many applications the filtering layer can reach a thickness of 10 mm. 2. The dirty filter fabric’s permeability is reduced, the liquid level starts increasing. The dirty liquid...
Open the catalog to page 8system correctly Better filtration Required filtration Poorer filtration system undersized ■Better filtration iPoorer filtration Chain system and lateral seal discs: Master is equipped with a corrugated chain and lateral discs, this system guarantees the perfect seal of contaminated liquid in the filtering section. Customizable for every customer need: This series' filters uses consumable filter media, which allows to change the filtration degree simply by changing the fabric type, always maintaining good results. Compared to other flat bed filters of the same capacity, gravity filter...
Open the catalog to page 9Master + Mediomaster + Minimaster DMD: Pre-filtration system with rotating magnetic discs for the separation of magnetic polluting particles from coolant. Skim: Superficial oil skimmer, it allows to lengthen coolant quality and eliminate odors generated by anaerobic bacteria. Collecting tank: for clean liquid Transfer tank: to collect dirty liquid for feeding the filter Pumps: for pressure from 0,1 to 100 bar for returning clean liquid Electrical equipment: for command and control Control system: for level and temperature of coolant
Open the catalog to page 10Losma S.p.A. Via E. Fermi 16 24035 Curno (BG) CAP. SOC. I.V. € 500.000,00 Reg. Imp. e P.I e C.F. 012345901962 R.E.A. 185685 Germany - Losma GmbH www.losma.de UK - Losma UK Limited www.losma.co.uk Losma Engineering - Torino www.losma.it India - Losma India Pvt Ltd www.losma.In
Open the catalog to page 12All LOSMA catalogs and technical brochures
-
Spring
12 Pages
-
Serie DMD
8 Pages
-
Serie Master
12 Pages
-
Pascal M
12 Pages
-
Extra
4 Pages
-
DMD Series
4 Pages
-
Spring Compact
12 Pages
-
Magneto
4 Pages
-
Skim
4 Pages
-
DTE
8 Pages
-
Pascal
4 Pages
-
Argos
4 Pages
-
Galileo Plus
8 Pages
-
Icarus
12 Pages
-
Darwin
12 Pages
-
CENTRALISED AIR SYSTEM CATALOGUE
22 Pages
-
DECOM
3 Pages
-
Filtering cloth
4 Pages
-
Superfilter
2 Pages
-
X26
4 Pages
-
Rotomag
2 Pages
-
Detex
6 Pages
-
Green
8 Pages
-
Newton
8 Pages
-
Products Catalogue
24 Pages
-
Demag
3 Pages
-
Pre Post Filter
14 Pages
-
Spark
2 Pages
-
Sirius
4 Pages
Archived catalogs
-
DARWIN
8 Pages
-
NEWTON
4 Pages
-
GEMINI
4 Pages
-
Product Range
24 Pages