![LOGITECH AUTOMAZIONE SRL - logo](https://img.directindustry.com/images_di/logo-p/L4566839.gif)
Catalog excerpts
![Bell helium test #19 - 2](https://img.directindustry.com/pdf/repository_di/4566839/bell-helium-test-19-1043028_2m.jpg)
BELL HELIUM TEST
Open the catalog to page 2![Bell helium test #19 - 3](https://img.directindustry.com/pdf/repository_di/4566839/bell-helium-test-19-1043028_3m.jpg)
MACHINE CYCLE 1- Component loading (in automatic or in manual mode according to the type of cycle selected) 2- Table rotation and start of the automatic test cycle 3- Locking of the component under test 4- Pressurization with helium up to the pressure set 5- Calculation of the component real leakage 6- Test result 7- Helium discharge into its storage system and air inlet into the component (ventilation) 8- Unlocking of the component after test 9- Component unloading (in automatic or manual mode according to the type of cycle selected)
Open the catalog to page 3![Bell helium test #19 - 5](https://img.directindustry.com/pdf/repository_di/4566839/bell-helium-test-19-1043028_5m.jpg)
Height: approx. 2.50 m Depth: approx. 2.50 m Width: approx. 3.50 m Total power installed: 7.50 kW Supply voltage: 220/380Vac Auxiliary power supply voltage: 24Vdc Phases: 3 + Neutral + Earth Frequency: 50Hz Pneumatic supply pressure: 200 Bar Total machine weight: approx. 1250 Kg
Open the catalog to page 5All LOGITECH AUTOMAZIONE SRL catalogs and technical brochures
-
Leak test in water #68
8 Pages
-
Teflon coating and drying #120
14 Pages
-
Cylinder lock making machine #85
11 Pages
-
Leak test stand #01
5 Pages