Bell helium test #19
1 /5Pages

Bell helium test #19

Bell helium test #19
1 /5Pages

Catalog excerpts

Bell helium test #19-3

MACHINE CYCLE 1- Component loading (in automatic or in manual mode according to the type of cycle selected) 2- Table rotation and start of the automatic test cycle 3- Locking of the component under test 4- Pressurization with helium up to the pressure set 5- Calculation of the component real leakage 6- Test result 7- Helium discharge into its storage system and air inlet into the component (ventilation) 8- Unlocking of the component after test 9- Component unloading (in automatic or manual mode according to the type of cycle selected)

 Open the catalog to page 3
Bell helium test #19-5

Height: approx. 2.50 m Depth: approx. 2.50 m Width: approx. 3.50 m Total power installed: 7.50 kW Supply voltage: 220/380Vac Auxiliary power supply voltage: 24Vdc Phases: 3 + Neutral + Earth Frequency: 50Hz Pneumatic supply pressure: 200 Bar Total machine weight: approx. 1250 Kg