ROYTRONIC EXCEL Series AD Manual

Product catalog summary
Precautions: The document stresses the importance of safety when handling LMI metering pumps. Users should wear protective clothing and ensure the pump materials are compatible with the chemicals used. Proper installation and secure tubing connections are crucial to prevent leaks and ensure safety. Electrical connections must comply with local codes, and the pump should be installed in a flood-free area.
Introduction: LMI is a leading manufacturer of metering pumps, offering various models with different control options. The manual provides guidance on installation, maintenance, and troubleshooting, emphasizing safety and proper handling.
Specifications: The pumps operate within a temperature range of 14 to 113°F and support voltages from 95 to 240 V. They are designed for different frequencies and have specific current and wattage requirements. The AD9 model includes a battery, and all models have specific fuse requirements.
Installation: Proper pump location and mounting are essential for optimal performance. The manual details different mounting options, such as flooded suction and suction lift, and provides instructions for tubing connections and valve installations.
Operation: The document outlines controls for adjusting pump output and provides start-up procedures for different head types. It explains methods for externally triggering or pacing the pumps, with specific modes for local and remote control.
Maintenance: Routine maintenance includes depressurizing the discharge line, replacing diaphragms, valves, and O-rings, and ensuring proper wiring. The manual provides detailed instructions for each maintenance task.
Troubleshooting: A section is dedicated to troubleshooting common issues, ensuring users can address problems effectively and maintain pump performance.
Unpacking Check List: Your package should contain items such as a metering pump, foot valve tubing, ceramic foot valve weight, injection check valve, and optional components like a four-function valve and external control cables. Inspect for damage upon receipt.
Installation Details:
  • Pump Location and Installation: Place the pump near the solution tank and electrical supply, ensuring it is accessible for maintenance and not exposed to temperatures above 113°F (45°C). Use UV-resistant tubing if exposed to sunlight.
  • Pump Mounting: Options include flooded suction and suction lift. Ensure vertical alignment of suction and discharge valves.
  • Tubing Connections: Follow specific instructions for different tubing sizes, ensuring proper ferrule and coupling nut placement. Avoid using clear vinyl tubing on the discharge side.
  • Four-Function Valves (4-FV): These valves provide pressure relief, line depressurization, anti-syphon, and back pressure functions. Installation involves assembling the valve body and routing tubing back to the supply tank.
  • FastPrime™ and AutoPrime™: These features assist in maintaining pump priming by managing vapors and gasses. Proper tubing connections are essential for functionality.
  • Foot Valve/Suction Tubing Installation: The foot valve should be vertical and positioned off the tank bottom to prevent sediment interference.
  • Injection Check Valve and Discharge Tubing Installation: Install the valve to prevent backflow, ensuring vertical positioning and proper tubing connections.
Operation Details:
  • Output Adjustment Controls: Includes power, mode selection, stroke speed adjustment, and LCD display for monitoring. The stroke adjustment knob allows for chemical displacement control.
  • Connectors: Various connectors are available for alarm, remote mode, and external control functions, with specific pin configurations for different signals and power supply.
  • Pin Functions: Includes Tank Empty and Tank Low signals, Ground/Return Connection, and Flow Monitor/Meter Connector functions.
  • Start-up and Adjustment: Detailed procedures for priming different pump heads are provided, involving setting speed and stroke adjustments and ensuring the pump is primed before proceeding to output adjustment.
  • Output Adjustment: Involves calculating pump output using a specific formula and calibrating for accuracy.
  • Calibrating Displayed Flow: A step-by-step calibration procedure is outlined to improve the accuracy of the pump's calculated flow.
  • External Triggering or Pacing: Describes methods for externally controlling pumps, including switch closure and transistor methods.
Maintenance Procedures:
  • Spare Parts Replacement and Routine Maintenance: Routine maintenance of elastomeric parts is essential, including replacing the Liquifram™, cartridge valves, O-rings, and the injection check valve spring.
  • Depressurizing the Discharge Line: Procedures for depressurizing the discharge line for pumps equipped with a 4-FV or FastPrime™ heads are provided.
  • Liquifram™ Replacement: Instructions for replacing the Liquifram™ and associated parts are provided, emphasizing safety precautions.
  • Cartridge Valve and O-ring Replacement: Procedures for replacing worn valves and O-rings are detailed.
  • Injection Check Valve Parts Replacement: Instructions for replacing worn parts such as the spring, seat, ball, and O-ring are provided.
  • FastPrime™ Valve O-Ring Replacement: Procedures for replacing O-rings and ensuring proper reassembly are detailed.
Troubleshooting:
  • Pump Will Not Prime: Check power, output settings, foot valve position, suction lift, and tubing orientation.
  • Pump Loses Prime: Ensure solution container is filled, foot valve is vertical, and check for air leaks.
  • Leakage at Tubing: Replace worn tubing ends, fittings, and seal rings.
  • Low Output or Failure to Pump Against Pressure: Check pressure ratings, replace worn parts, and ensure correct stroke length.
  • Failure to Run: Verify power supply and check EPU and pulser functionality.
  • Excessive Pump Output: Address syphoning issues and ensure proper pressure at injection point.
Additional Information: Refer to the LMI Metering Pump Price List for spare parts kits and consult the LMI Online Library for the latest liquid end information.
See more

Catalog excerpts

ROYTRONIC EXCEL Series AD Manual-1

Instruction Manual ROYTRONIC EXCEL™ Series AD Electronic Metering Pumps For file reference, please record the following data: Model No: _____________________________________ Serial No: _____________________________________ Installation Date: ________________________________ Installation Location: _____________________________ When ordering replacement parts for your LMI Metering Pump or Accessory, please include complete Model Number and Serial Number of your unit. Carefully read and understand all precautions before installing or servicing any metering pump. 201 Ivyland Rd. Ivyland, PA 18974 TEL: (215) 293-0401 FAX: (215) 293-0445 www.lmipumps.com Lit# 2024.C 10/2011

 Open the catalog to page 1
ROYTRONIC EXCEL Series AD Manual-2

ROYTRONIC EXCEL™ Series AD Model AD 2 5 1 - 8 3 8 S I Model Code Configuration *VU[YVS *VKL AD2 - Dual Manual Control – Digital: Stroke frequency and length manually adjustable with digital LCD display, low level indication (remote input). Display configurable to indicate calculated pump flow. AD8 - Pulse/Analog Input w/ Dual Manual Control – Digital: Pulse or 4-20 mA signal input controls frequency, digital LCD display, manual stroke length control, frequency manually adjustable when in local control, pulse multiply/divide functions, 24 V output for remote device. Includes dual low level float...

 Open the catalog to page 2
ROYTRONIC EXCEL Series AD Manual-3

Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.2 Unpacking Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation. . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
ROYTRONIC EXCEL Series AD Manual-4

1.0 PRECAUTIONS The following precautions should be taken when working with LMI metering pumps. Please read this section carefully prior to installation. Protective Clothing ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on the solution being pumped. Refer to MSDS precautions from your solution supplier. Water Pre-Prime All LMI pumps are pre-primed with water when shipped from the factory. If your solution is not compatible with water, disassemble the Pump Head Assembly. Thoroughly...

 Open the catalog to page 4
ROYTRONIC EXCEL Series AD Manual-5

Back Pressure/Anti-Syphon Valve If you are pumping downhill or into low or no system pressure, a back pressure/antisyphon device such as LMI’s Four-Function Valve should be installed to prevent overpumping or syphoning. Contact your LMI distributor for furthur information. Electrical Connections WARNING: To reduce the risk of electrical shock, the metering pump must be plugged into a properly grounded grounding-type receptacle with ratings conforming to the data on the pump control panel. The pump must be connected to a good ground. Do not use adapters! All wiring must conform to local electrical...

 Open the catalog to page 5
ROYTRONIC EXCEL Series AD Manual-6

2.0 Introduction LMI is the world’s most versatile manufacturer of economical and efficient metering pumps. This manual addresses the installation, maintenance and troubleshooting procedures for manually and externally controlled pumps. LMI has a worldwide network of stocking representatives and authorized repair centers to give you prompt and efficient service. Please review this manual carefully. Pay particular attention to warnings and precautions. Always follow good safety procedures, including the use of proper clothing, eye and face protection. AD2XY (where X is any number; where Y is 1,...

 Open the catalog to page 6
ROYTRONIC EXCEL Series AD Manual-7

UNPACKING CHECK LIST 2.2 Unpacking Check List Your carton will contain many or all of the following items. Please notify the carrier immediately if there are any signs of damage to the pump or its parts. Metering Pump Ceramic Foot Valve Weight Foot Valve Injection Check Valve External Control Cable (0, 1, or 2 Cables) Four-Function Valve (Optional) Tube Connection Hardware 7

 Open the catalog to page 7
ROYTRONIC EXCEL Series AD Manual-8

Pump Location and Installation Locate pump in an area convenient to solution tank and electrical supply. The pump should be accessible for routine maintenance, and should not be operated in ambient temperatures above 113°F (45°C). If the pump will be exposed to direct sunlight, LMI black, UV resistant tubing should be installed. This pump is cord connected and not intended for permanent mounting to a building. However, temporary mounting to stabilize the pump during operation may be necessary as long as tools are not required for the installation or removal of the pump. Pump Mounting The pump...

 Open the catalog to page 8
ROYTRONIC EXCEL Series AD Manual-9

3.2.2 Suction Lift - Wall Bracket Mount The pump may be mounted using an LMI Wall Mount Bracket Assembly (part no. 34643) directly above the solution tank. A pump mounted in this manner allows for easy changing of solution tanks or drums. 3.2.3 Suction Lift - Tank Mount The pump may be mounted on a LMI 10-gallon tank (part no. 27421), 35-gallon tank (part no. 27400), and 50-gallon tank (part no. 26350). 3.2.4 Suction Lift - Shelf Mount The pump may be mounted on a shelf (customer supplied) maintaining a suction lift of less than 5 ft (1.5 m).

 Open the catalog to page 9
ROYTRONIC EXCEL Series AD Manual-10

Tubing Connections ,QVHUW WXELQJ WKURXJK &RXSOLQJ 1XW²7XELQJ VKRXOG HQWHU WKH VPDOOHU HQG RI WKH &RXSOLQJ 1XW ¿UVW RULHQWLQJ the larger opening of the Coupling Nut toward the tubing end. 2a. For 1/4” OD tubing: Position the Female Ferrule so that 1/4” to 3/8” (5-10 mm) of tubing protrudes from the Female Ferrule. Orient the raised collar of the Ferrule toward the Coupling Nut (reference FIGURE 1). 2b. For 3/8” or 1/2” OD tubing: Position a Female Ferrule about one inch (25 mm) from end of tubing. Orient the UDLVHG FROODU RI WKH )HPDOH )HUUXOH WRZDUG WKH &RXSOLQJ 1XW 7KHQ LQVHUW WKH 0DOH )HUUXOH...

 Open the catalog to page 10
ROYTRONIC EXCEL Series AD Manual-11

Four-Function Valves (4-FV) Your pump may be equipped with a 4-FV, or standard discharge valve. If your pump is not equipped with a four-function valve and you feel it is needed in your application, it can be purchased as an accessory. Contact your local LMI stocking distributor. The features of a 4-FV are listed below. 1. Pressure Relief: If the discharge line is over pressurized, the valve opens sending solution back to the supply tank. 2. Line Depressurization: Opening the relief knob provides line drain back to the supply tank. 3. Anti-Syphon: Prevents syphoning when pumping solution downhill...

 Open the catalog to page 11