Electronic Metering Pump Instruction Manaual

Electronic Metering Pump Instruction Manaual
1 / 44 PagesView full catalog

Electronic Metering Pump Instruction Manaual

Product catalog summary
Introduction
This manual is for LMI's economical and efficient metering pumps, covering installation, maintenance, and troubleshooting for Series AA, B, C, E, J5, and P pumps. It highlights safety precautions, such as using protective clothing and eye protection.

Spare Parts
Annual replacement of elastomeric components is advised, with spare part kits available from LMI distributors.

Unpacking Check List
Upon receipt, check for damage and ensure all parts, including tubing and foot valve, are included.

Pre-Installation Instructions
Verify pump material compatibility with the solution. Use LMI tubing and follow safety precautions, avoiding vinyl tubing on pressurized lines.

Installation
  • Pump Location and Installation: Install in a convenient location, avoiding temperatures above 122°F (50°C). Use UV-resistant tubing if exposed to sunlight.
  • Pump Mounting: Options include flooded suction, suction lift with wall bracket, tank mount, or shelf mount, ensuring vertical suction and discharge valves.
  • Electrical Connections: Use a GFCI-protected circuit and ensure proper grounding, following local electrical codes.

Tubing Connections
Use only LMI tubing, ensuring secure connections. Avoid using pliers on coupling nuts and do not reuse ferrules.

Multi-Function Valves
Pumps may include a 3-FV or 4-FV valve for pressure relief, line depressurization, and priming aid, available separately if not included.

Start-Up and Adjustment
Instructions for output adjustment, start-up, and priming are provided, with specific procedures for pumps with or without multi-function valves.

Calibration
Includes pressure control and on-site volumetric calibration procedures.

Spare Parts Replacement/Routine Maintenance
Guidelines for depressurizing the discharge line, replacing the diaphragm, and other components are detailed.

Troubleshooting
A troubleshooting section addresses common issues.

Additional Information
An EPU resistance chart is provided on the back cover for reference.
Overview
This document provides detailed instructions for the installation, operation, and maintenance of LMI pumps, focusing on components such as the 4-Function Valve, AutoPrime™ Liquid End, and various installation procedures.

Key Components and Functions
  • 4-Function Valve: Prevents over-pumping and syphoning, provides back pressure, and includes a relief knob for line drainage.
  • AutoPrime™ Liquid End: Automatically removes vapors and gases, ensuring the pump remains primed.
  • Foot Valve: Acts as a check valve to maintain priming in suction lift applications.
  • Injection Check Valve: Prevents backflow and should be installed at the chemical injection point.

Installation Procedures
  • 4-Function Valve Installation: Involves mounting to the pump, connecting tubing, and ensuring proper positioning for pressure relief.
  • AutoPrime™ Liquid End Installation: Requires connecting tubing to the supply tank and ensuring it is not submerged.
  • Foot Valve Installation: The valve must be positioned vertically and slightly above the tank bottom to avoid sediment.

Start-Up and Priming
  • With Multi-Function Valve: Involves setting speed and stroke knobs, opening the relief side, and ensuring the pump is primed.
  • Without Multi-Function Valve: Similar steps as above but without the relief valve adjustments.
  • AutoPrime™ Heads: Utilizes the AutoPrime™ valve to purge air and ensure priming.

Output Adjustment and Calibration
  • Output is calculated based on maximum pump output, speed, and stroke settings.
  • Calibration involves measuring output over time and adjusting speed and stroke as necessary.

Maintenance and Spare Parts
  • Regular maintenance includes replacing elastomeric parts like the Liquifram™, cartridge valves, and seal rings.
  • Depressurizing the discharge line is crucial before maintenance.

Safety Precautions
Always wear protective clothing and equipment when performing maintenance or handling chemicals.
Specifications and Procedures
This document provides detailed procedures for maintaining and troubleshooting LMI metering pumps. Key procedures include flushing the pump head with water or a neutralizing solution, replacing the Liquifram™, and ensuring proper alignment and installation of pump components. The document emphasizes the importance of wearing protective clothing and following safety precautions during maintenance.

Liquifram™ Replacement
The process involves setting the stroke knob to zero, removing the old Liquifram™, and installing a new one. The Liquifram™ Stroke Setting Chart provides specific settings based on pump series numbers. Proper alignment and tightening of screws are crucial to ensure optimal pump performance.

Cartridge Valves and Seal Rings Replacement
Instructions for replacing cartridge valves, seal rings, and injection check valve springs are provided. The document stresses the importance of noting the orientation of valves before disassembly and following the instructions included with replacement kits.

Troubleshooting
The troubleshooting section addresses common issues such as pump not priming, losing prime, leakage, low output, and failure to run. Solutions include checking power supply, ensuring proper installation of components, and replacing worn parts. The document provides specific guidance on adjusting the stroke knob and checking the pump for proper zero position.

EPU Resistance Chart
The document includes an EPU Resistance Chart for checking coil resistance at different voltages and temperatures. This is essential for diagnosing electrical issues with the pump.

Contact Information
For further assistance, contact details for Milton Roy LLC are provided, including phone numbers and a website link.
See more

Catalog excerpts

Electronic Metering Pump Instruction Manaual-1

___ Instruction Manual Electronic Metering Pumps Carefully read and understand all precautions before installing or servicing any metering pump. For file reference, please record the following data: Installation Date: Installation Location: When ordering replacement parts for your LMI Metering Pump or Accessory, please include complete Model Number and Serial Number of your unit. 201 Ivyland Road Ivyland, PA 18974 TEL: (215) 293-0401 FAX: (215) 293-0445 www.lmipumps.com

 Open the catalog to page 1
Electronic Metering Pump Instruction Manaual-4

1.0 Introduction LMI is the world’s most versatile manufacturer of economical and efficient metering pumps. This manual addresses the installation, maintenance and troubleshooting procedures for manually and externally controlled pumps. LMI has a worldwide network of stocking representatives and authorized repair centers to give you prompt and efficient service. Please review this manual carefully. Pay particular attention to warnings and precautions. Always follow good safety procedures, including the use of proper clothing, eye and face protection. This manual is for Series AA, B, C, E, J5,...

 Open the catalog to page 4
Electronic Metering Pump Instruction Manaual-5

Example: Your pump consists of two main components: 1. The Drive Assembly; and 2. The Liquid Handling Assembly. Liquid Handling Assembly

 Open the catalog to page 5
Electronic Metering Pump Instruction Manaual-6

2.0 Unpacking Check List Your carton will contain many or all of the following items. Please notify the carrier immediately if there are any signs of damage to the pump or its parts. Please refer to the enclosed Instruction Supplement for an illustration and electrical diagram of your complete pump. Metering Pump Foot Valve Ceramic Foot Valve Weight Tubing Depending on the model, your carton may contain 0, 1, 2 or 3 rolls of tubing. Your carton may contain a roll of vinyl tubing: DO NOT USE ON PRESSURIZED LINES. The vinyl tubing is for connection to the SUCTION SIDE OF THE PUMP HEAD OR THE 3...

 Open the catalog to page 6
Electronic Metering Pump Instruction Manaual-7

Instruction Supplement Injection Check Valve Instruction Supplement Optional Milliamp Input Cable Optional 4-Function Valve (pictured) or Optional 3-Function Valve

 Open the catalog to page 7
Electronic Metering Pump Instruction Manaual-8

3.0 Pre-Installation Instructions The following precautions should be taken when working with LMI metering pumps. Please read this section carefully prior to installation. Protective Clothing ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on the solution being pumped. Refer to MSDS precautions from your solution supplier. Water Pre-Prime All LMI pumps are pre-primed with water when shipped from the factory. If your solution is not compatible with water, disassemble the Pump Head...

 Open the catalog to page 8
Electronic Metering Pump Instruction Manaual-9

Fittings And Machine Threads All fittings should be hand-tightened. An additional 1/8 - 1/4 turn after the fitting contacts the seal ring may be necessary to provide a leak-proof seal. Excessive overtightening or use of a pipe wrench can cause damage to the fittings, seals, or pump head. All LMI pumps have straight screw machine threads on the head and fittings and are sealed by the seal rings or O-rings. DO NOT use Teflon® tape or pipe dope to seal threads. Teflon® Tape may only be used on the 1/2" NPT thread side of the Injection Check Valve as well as stainless steel liquid end connections....

 Open the catalog to page 9
Electronic Metering Pump Instruction Manaual-10

Electrical Connections To reduce the risk of electrical shock, install only on a circuit protected by a ground-fault circuit-interrupter (GFCI). The metering pump must be plugged into a grounded outlet with ratings conforming to the data on the pump control panel. The pump must be connected to a good ground. DO NOT USE ADAPTERS! All wiring must conform to local electrical codes. WARNING: Do not hook a US style pump plug into a non-US (UK, Aust, NZ or Swiss) wired power system. The US style 240VAC power system has two 110VAC hot legs and one neutral. The European style system has one 240VAC hot...

 Open the catalog to page 10
Electronic Metering Pump Instruction Manaual-11

Flooded Suction The pump is mounted at the base of the storage tank. This installation is the most trouble-free , and is recommended for very low outputs, solutions that gasify, and high-viscosity solutions. Since the suction tubing is filled with solution, priming is accomplished quickly and the chance of losing prime is reduced. When pumping downhill or into low or no pressure system, a back pressure/anti-syphon device should be installed to prevent overpumping or syphoning. Although popular for all solutions, LMI recommends flooded suction installations for all high-viscosity fluid applications....

 Open the catalog to page 11
Electronic Metering Pump Instruction Manaual-12

Suction Lift - Wall Bracket Mount The pump may be mounted using an LMI Wall Mount Bracket Assembly (part no. 34643) directly above the solution tank. A pump mounted in this manner allows for easy changing of solution tanks or drums. Tee Injection Check Valve LMI Pump Rear Mount LMI Pump Front Mount Solution Tank 2.0 in. (50 mm) Space for Sediment Accumulation 12 Pressure Line

 Open the catalog to page 12
Electronic Metering Pump Instruction Manaual-13

Suction Lift - Tank Mount The pump may be mounted on a molded tank provided there is a recess to keep the pump stationary. LMI 10-gallon tank (part no. 27421), 35-gallon tank (part no. 27400), and 50-gallon tank (part no. 26350) have molded recesses for pump mounting. Pressure Line Tee Injection Check Valve LMI Pump LMI 50 Gallon Solution Tank LMI 10 Gallon Solution Tank Ceramic Weight Foot Valve Foot Valve 2.0 in. (50 mm) Space for Sediment Accumulation 2.0 in. (50 mm) Space for Sediment Accumulation

 Open the catalog to page 13
Electronic Metering Pump Instruction Manaual-14

Suction Lift - Shelf Mount The pump may be mounted on a shelf (customer supplied) maintaining a suction lift of less than 5 ft (1.5 m). An LMI mounting kit (part number 10461) is available for securing the pump to a shelf. Flow Injection Check Valve Anti-Syphon Pressure Relief Valve (Optional Accessory) Solution Drum 2.0 in. (50 mm) Space for Sediment Accumulation

 Open the catalog to page 14
Electronic Metering Pump Instruction Manaual-15

Tubing Connections 1.   Insert tubing through Coupling Nut—Tubing should enter the smaller end of the Coupling Nut first, orienting the larger opening of the Coupling Nut toward the tubing end. 2a.  1/4” OD tubing: Position the Female Ferrule so that 1/4” to 3/8” (5-10 mm) of For tubing protrudes from the Female Ferrule. Orient the raised collar of the Ferrule toward the Coupling Nut (reference FIGURE 1). 2b.  or 3/8” or 1/2” OD tubing: Position a Female Ferrule about one inch (25 mm) F from end of tubing. Orient the raised collar of the Female Ferrule toward the Coupling Nut. Then, insert the...

 Open the catalog to page 15