05.06.1961 Leo Möskes established a rm in sole proprietorship for the manufacture of wastewater treatment systems in Röthenbach near Nuremberg / Germany. In control cabinets that were operated around dew point terperatures, at that time, light bulbs were installed to avoid falling below dew point temperature by means of the light bulb's waste heat. 01.10.2002 The Achter Elektronik AG aquires the partner's interest share of Lm-therm Gmbh. 12.08.1993 Foundation of the rm in sole proprietorship: Franz Achter Elektrohandel & Systemtechnik Achter Elektronik AG and Lm-therm GmbH utilize the...

Open the catalog to page 2
Complete catalog - 3

Cable technology • Product series

Open the catalog to page 3
Complete catalog - 4

^ ^^^^ Ccrti Heal ion bescheinigt hiermit, dass das Unternehmen Achter Elektronik AG: Entwicklung, Herstellung und Vertrieb von elektrischen und elektronischen Geraten und Kabelsystemen Lm-therm GmbH: Entwicklung und Vertrieb von Schaltschrankheizgeraten SulzbachstraBe 15 * D-94501 Aldersbach OT Freundorf EggerstdorferstraBe 4 * D-94501 Aldersbach, OT Uttigkofen ein Qualitatsmanagementsystem entsprechend der oben genannten Norm (12/2000) eingefuhrt hat und dieses wirksam anwendet. Der Nachweis wurde im Rahmen des Zertifizierungs-Audits Bericht-Nr. A08031100 erbracht. Dieses Zertifikat ist...

Open the catalog to page 4
Complete catalog - 5

To what should attention be paid in control cabinet climatization? Required heating capacity (values based on experience) A. Heaters with integrated thermostat For industrial applications C. Ventilator / blower heaters Customer-specific heater solutions/mounting, Product ranges: - the safe heater solution for any application -

Open the catalog to page 5
Complete catalog - 6

Why is heating respectively cooling necessary inside control cabinets? Meanwhile - as it is known, also the subject "control cabinet cooling" has become fairly important in addition to control cabinet heating. • Control cabinet climatization: heating and / or cooling! • Temperature/humidity or also temperature and humidity! Multifarious fields of application show that this issue is not only prevailing in the control cabinet: automation, traffic and automotive engineering, telecommunication, switchboard and control pa- nel systems, distributor control cabinet systems, read-out displays in...

Open the catalog to page 6
Complete catalog - 7

Required heating capacity (values based on experience) To successfully prevent formation of condensation water, the temperature inside an enclosure must not drop below dew point temperature.

Open the catalog to page 7
Complete catalog - 8

Determination of heating/cooling power required Single cabinet, free standing Single cabinet, at wall Cabinet wall, left / right end free-standing Cabinet wall, left / right end at wall Cabinet wall, middle part, free-standing Cabinet wall, middle part, at wall Cabinet wall, middle part, at wall + top covered Length L = ____ m ) Width W = ____ m ) Area A= ____ m2 Height H = ____ m ) 2. k-value of cabinet material /°C /°C k = 12 W/m2/°C k = 3,7 W/m2/°C 2 2 Aluminium enclosure Stainless steel enclosure 3. Environs facts Timax Timin Maximum inside temperature permissible Minimum inside...

Open the catalog to page 8
Complete catalog - 9

General details on control cabinet climatization A uniform heat distribution is obtained by installing the heater in the lower third of the control cabinet ^ - cooling units however should be installed in the upper area. $ It should be attempted not to influence the natural convection of heating by an extreme packing den- sity of built-in components installed. By installation of air circulation fans respectively ventilator hea- ters, effectiveness and heat distribution can be optimized! Cooling units are equipped with ventilators 3) Surface temperatures at PTC heaters Because of high...

Open the catalog to page 9
Complete catalog - 10

The appropriate solution for your A. Heaters with integrated thermostat (catalogue pages 13-21 Our heaters consist of ceramic heating elements integrated into an aluminum casing designed to thermal specifications with built-in 2-position bi- metal temperature controller. The resistors and power curves of this heating system show linear 1) The built-in temperature controller provides for operational safety. 2) Because of the built-in temperature controller, high surface temperatures that might influence the built-in components in their functional relia- bility or damage them do no occur. 3)...

Open the catalog to page 10
Complete catalog - 11

• Heaters with integrated thermostat • Ventilators and blower heaters climatization task! C. Ventilators and blower heaters For heating capacity ranges above 500 W, or also under installation conditions with difficult convec- tion, the application of ventilators and blower hea- 1) Active convection and very high thermal effi- ciency because of built-in high-quality ventila- 2) These devices can also provide sufficient he- ating capacity in more performance-intensive areas (e.g. in colder regions down to - 40 °C) (heating capacities from 250 to 8000 W). 3) Excess temperature protection...

Open the catalog to page 11
Complete catalog - 12

Industrial heater technology - index by heating capacity • 3 Heating systems (A - C) for industrial application - look at page 10/11! • Heaters for general applications (D) • Ex-heaters / Ex-temperature control A) Heaters with integrated (screw-in or fastening flansh) for industrial- or heater water PTC-heater with integrated Ex-temperature control

Open the catalog to page 12
Complete catalog - 13

Control cabinet heating device with integrated thermostat Power rating Voltage Standard program Connection Mounting Protection class position Protection type Voltage Temperature Fixture Connection Special voltage Notice to the order code Power rating Order index Order index Order index Order index • Slight surface temperature by the use of • No additional thermostat necessary • Special temperature settings selectable Wiring diagram Dimensioned drawing

Open the catalog to page 13
Complete catalog - 14

Control cabinet heating device with integrated thermostat Power rating Voltage Standard program Temperature Fixture Connection Mounting Protection class settings position Protection type Special voltage Notice to the order code Power rating & Longer cable Order index Only with screw fastening • Slight surface temperature by the use of • No additional thermostat necessary Please use order index ULC Wiring diagram Dimensioned drawing