A010-D1
80Pages

{{requestButtons}}

Catalog excerpts

A010-D1 - 1

• Cable technology • Product series Central catalogue

Open the catalog to page 1
A010-D1 - 2

Our prole! 05.06.1961 Leo Möskes established a rm in sole proprietorship for the manufacture of wastewater treatment systems in Röthenbach near Nuremberg / Germany. In control cabinets that were operated around dew point terperatures, at that time, light bulbs were installed to avoid falling below dew point temperature by means of the light bulb's waste heat. 01.10.2002 The Achter Elektronik AG aquires the partner's interest share of Lm-therm Gmbh. 12.08.1993 Foundation of the rm in sole proprietorship: Franz Achter Elektrohandel & Systemtechnik Achter Elektronik AG and Lm-therm GmbH...

Open the catalog to page 2
A010-D1 - 3

• Cable technology • Product series Switchgear construction

Open the catalog to page 3
A010-D1 - 4

ISO 14001 Environmental Certication planned for 2010 Technical modications and further developments of our products reserved. Errors, misprints, and technical alterations do not give reason to claims for damages. For customer-specic developments, solely the customer's specications (drawings and/or requirement specications) do apply. 4

Open the catalog to page 4
A010-D1 - 6

Why is heating respectively cooling necessary inside control cabinets? Meanwhile - as it is known, also the subject "control cabinet cooling" has become fairly important in addition to control cabinet heating. * Control cabinet climatization: heating and / or cooling! • Temperature/humidity or also temperature and humidity! Multifarious fields of application show that this issue is not only prevailing in the control cabinet: automation, traffic and automotive engineering, telecommunication, switchboard and control pa- nel systems, distributor control cabinet systems, read-out displays in...

Open the catalog to page 6
A010-D1 - 7

Installation in indoor rooms Size of enclosure volume in dm³ up to up to Indoors heated Indoors unheated 10 W 20 W 30 W 30 W 20 W 33 W 20 30 up to up to up to up to up to up to Installation outdoors 100 120 160 240 300 420 up to 600 up to 800 up to 1000 up to 1200 Set up outdoors 40 W 130 W 130 W 180 W 180 W 180 W 240 W 280 W 280 W 280 W 360 W 130 W 130 W 130 W 180 W 310 W 360 W 630 W 810 W 1300 W Thermal dissipation losses of built-in control switching and command devices are unaccounted for in this table. For a more exact calculation of the required heating power, please use the master...

Open the catalog to page 7
A010-D1 - 9

General details on control cabinet climatization A uniform heal distribution is obtained by installing the heater in the lower third of the control cabinet - cooling units however should be installed in the upper area. It should be attempted not to influence the natural convection of heating by an extreme packing den- sity of built-in components installed. By installation of air circulation fans respectively ventilator hea- ters, effectiveness and heat distribution can be optimized! Cooling units are equipped with ventilators 3) Surface temperatures at PTC heaters Because of high surface...

Open the catalog to page 9
A010-D1 - 10

The appropriate solution for your A. Heaters with integrated thermostat (catalogue pages 13-21) Our heaters consist of ceramic heating elements integrated into an aluminum casing designed to thermal specifications with built-in 2-position bi- metal temperature controller. The resistors and power curves of this heating system show linear 2) Because of the built-in temperature controller, high surface temperatures that might influence the built-in components in their functional relia- bility or damage them do no occur. 3) Default setting of the built-in temperature con- troller Is preset to a...

Open the catalog to page 10
A010-D1 - 11

• Heaters with integrated thermostat • Ventilators and blower heaters climatization task! C. Ventilators and blower heaters For heating capacity ranges above 500 W, or also under installation conditions with difticult convec- tion, Ihe application of ventilators and blower hea- 1) Active convection and very high thermal effi- ciency because of built-in high-quality ventila- 2) These devices can also provide sufficient he- ating capacity in more performance-intensive areas (e.g. In colder regions down to - 40 °C) (heating capacities from 250 to 8000 W). 3) Excess temperature protection...

Open the catalog to page 11
A010-D1 - 13

Control cabinet heating device Heating technology with integrated thermostat Type super-mini Connection cable AL Standard program Voltage 10 W Temperature settings 230V AC (Own temperature) 20 W Fixture Connection Snapmounting for DIN-rail Mounting position Order No. Connection 200g 23010AL0 vertical 23020AL0 Notice to the order code 230 20 AL 0 *** Options Voltage Temperature Fixture Connection Voltage Power rating Connection only AL possible alternatively put in special voltage Art of voltage Additional options DC= 1 AC= 0 Longer cable Order index Screw fastening Order index S Tropic...

Open the catalog to page 13
A010-D1 - 14

Control cabinet heating device with integrated thermostat ir rating Voltage Temp era tur Standard program Special voltage • Slight surface temperature by the use • No additional thermostat necessary Please use order index ULC Wiring diagram Dimensioned drawing

Open the catalog to page 14
A010-D1 - 15

Control cabinet heating device with integrated thermostat Standard program (Own temperature) ,e__ 3x0,75 mill' Vertical • Slight surface temperature by the us • No additional thermostat necessary • Special temperature settings Please use order index ULC Wiring diagram Dimensioned drawing

Open the catalog to page 15
A010-D1 - 16

Control cabinet heating device with integrated thermostat Type Connection cable AL Standard program Voltage Temperature settings 33 W 230 V AC (Own temperature) Fixture Snapmounting for DIN-rail Connection Mounting position Order No. 23033LAL0 Connection 600g 230100LAL0 horizontal Notice to the order code 230 L AL 0 *** Options Voltage Temperature Fixture Connection Voltage Power rating Connection only AL possible alternatively put in special voltage Art of voltage Additional options DC= 1 AC= 0 Longer cable Order index Screw fastening Order index S Anti-freeze On<10°C Off 40°C Order index...

Open the catalog to page 16
A010-D1 - 17

Control cabinet heating device with integrated thermostat Standard program Notice to the order code • Slight surface temperature by the us • No additional thermostat necessary • Special temperature settings Please use order index ULC Wiring diagram Dimensioned drawing

Open the catalog to page 17

All Lm-therm catalogs and technical brochures