Group: Littelfuse
Catalog excerpts
Littelfuse* Expertise Applied | Answers Delivered Protection Relays & Controls Neutral-Grounding-Resistor Monitoring Neutral-Grounding-Resistor Monitor - Previous Revision Simplified Circuit Diagram Description The SE-330 is an advanced ground-fault and neutral-grounding-resistor monitoring relay. It measures neutral current, neutral-to-ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum, and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. Resistor Monitoring The SE-330 combines the measured values of resistance, current, and voltage to continuously determine that the NGR is intact. It is able to detect a resistor failure with or without a ground fault present. Sensing resistors are matched to the system voltage and are used to monitor NGRs on systems up to 72 kV Ground-Fault Monitoring The SE-330 uses an application-appropriate current transformer to reliably detect ground-fault currents as small as 100 mA. DFT filtering ensures that false trips due to harmonic noise from adjustable-speed drives do not occur. Should the resistor open and a ground fault subsequently occur, the SE-330 will detect the fault through voltage measurement, while other current-only sensing relays would be ineffective. Ordering Information For detailed wiring diagram, see adjacent page. Pulsing Ground-Fault Location The SE-330 is capable of controlling a pulsing contactor, which is used to switch the NGR resistance in a pulsing-compatible NGR package. The resulting ground-fault current is distinguishable from charging currents and noise and will only appear upstream of the ground fault, making fault location fast and easy, even without isolating feeders or interrupting loads. Accessories ER Series Sensing Resistor Required interface between the power system and the /wwHV. Eliminates hazardous voltage levels at the relay. EFCT Series Ground-Fault Current Transformer Sensitive ground-fault current detection (5 A primary). SE-CS30 Series Ground-Fault Current Transformer Sensitive ground-fault current detection (30 A primary). Other Current Transformer For low-resistance NGRs choose a CT primary approximately equal to the NGR rating. Littelfuse reserves the right to make product changes, without notice. Material in this document is as accurate as known at the time of publication. Visit Littelfuse.com for the most up-to-date information. © 2014 Littelfuse Protection Relays & Controls Littelfuse.com/se-330 Littelfuse.com/se-330hv Rev: 4-E-112513 Based on SE-330 Manual Rev: 9-A-112913 Based on SE-330 HV Manual Rev: 4-A-112913
Open the catalog to page 1Littelfuse* Expertise Applied | Answers Delivered Protection Relays & Controls Neutral-Grounding-Resistor Monitoring Neutral-Grounding-Resistor Monitor - Previous Revision FEATURES IEEE # BENEFITS Continuous NGR monitoring Ground-fault detection Detects resistor failure within seconds, reduces transient-overvoltage risk, removes risk of ground-fault-detection failure Main or backup protection to detect a ground fault anywhere on the monitored system Adjustable pickup (2-100%) Adjustable time delay (0.1-10 s) Universal CT compatibility Output contacts Analog output (4 - 20 mA) Pulsing output...
Open the catalog to page 2All Littelfuse catalogs and technical brochures
-
Fuse Fundamentals
20 Pages
-
INDUSTRIAL CIRCUIT PROTECTION
292 Pages
-
SURGE PROTECTIVE DEVICES
32 Pages
-
HIGH-SPEED SEMICONDUCTOR
72 Pages
-
Power Semiconductor & IC
133 Pages
-
Dc Disconnect Switches
2 Pages
-
ESR_Fuse_Datasheet
6 Pages
-
ELECTRICAL COILS
2 Pages
-
PRODUCTS FOR AGRICULTURE
36 Pages
-
CIRCUIT PROTECTION
15 Pages
-
MSL Classification
2 Pages
-
SE-325 SERIES (PGM-8325)
1 Pages
-
SE-CS10 SERIES
2 Pages
-
ECSW SERIES
3 Pages
-
LSR-0
1 Pages
-
LSRU SERIES
2 Pages
-
LSRX / LSRX-C SERIES
2 Pages
-
50R-400-ALT
1 Pages
-
ALT SERIES
2 Pages
-
05903300 & 05903500 RELAYS
1 Pages
-
05930100 & 05930800 RELAYS
1 Pages
-
05931300 & 05931600 RELAYS
1 Pages
-
QJxx30LH4 series
6 Pages
-
Thyristors QJ8012xHx Series
8 Pages
-
30KPA-HRA Series
7 Pages
-
AK1-Y Series
4 Pages
-
QJxx40xx Series
8 Pages
-
TS Series
11 Pages
-
Littelfuse SIDACtor Products Catalog
239 Pages
-
Electronic Fuse Products Catalog
409 Pages
-
Passenger Car Catalog
60 Pages
-
Polyfuse PPTC Catalog
128 Pages
-
POWRGARD Electrical Product Catalog
202 Pages
-
Protection Relays SSAC Catalog
524 Pages
-
Sensors Products Catalog
20 Pages
-
SIDACtor Catalog
239 Pages
-
TVS Diode Array (SPA) Catalog
215 Pages
-
Varistors Catalog
254 Pages
-
SOLAR PRODUCTS CATALOG
28 Pages
-
MP8000
2 Pages
-
MicroPlex® SSR18 AND SSR30
2 Pages
-
606 Series
3 Pages
-
ST Series
3 Pages
-
885 Series Fuse
3 Pages
-
MicroPlex® 7X, 7H, & 7L
2 Pages
-
TPSMB Series
6 Pages
-
TPSMD Series
6 Pages
-
ISOBUS SYSTEM
2 Pages
-
POLYFUSE®
6 Pages
-
Passenger Car Solutions
60 Pages
-
TVS Diode Catalog
174 Pages
-
Switching Thyristor Product Catalog
442 Pages
Archived catalogs
-
AFTERMARKET PRODUCTS CATALOG
136 Pages
-
AFTERMARKET PRODUCTS CATALOG 2018
132 Pages
-
Littelfuse Thyristor Catalog
467 Pages