Short Form Catalogue Arc-fault Protection System Protection of Switchboards • Improve personnel safety. Arcing faults in switchboards can cause severe damage against material as well as personnel. • Minimize production down time. The main issue is that no two arcing are the same, and it is therefore very difficult to know in advance how to prevent them. Whenever arcing occurs the pressure generated by the rapid increase in temperature is strong enough to break off cabinet doors. Further the light of the arcing, ultraviolet, and infrared, is dangerous for personnel, eyes and skin. • Reduce damage to material and the cost of repair or replacement. All of the above points should be taken into consideration in the Total Cost of Ownership, TCO, of a switchboard, and by using the SELCO Arc Detecting Relays you will be able to reduce these costs and eliminate the points listed.
Open the catalog to page 1Arc-fault Protection System The SELCO Arc-fault Protection System is based on experience with arc protection since 1962. The system units are built into boxes all fitting 35mm DIN-rails. Front plates are dimensioned to fit into the 45mm slot in the cover plates of a DIN-system. Arc Detecting Relay/ Current Relay/Time Relay To be placed in the switchboard or in connection with it. It is recommended that the Arc Detecting Relay, the Current Relay and the Time Relay are installed in the relay box or otherwise separated from the circuit breaker to be tripped. The Arc Detecting Relay is...
Open the catalog to page 2Arc-fault Protection D0100 Arc Detecting Relay for 24-220V DC battery supply For use with: · A0200 · A0300 · D0400 · D0500 · D0700 The D0100 is a detecting relay which can monitor up to 16 arc detectors in parallel through D0400 or D0500 Junction Boxes. In case of an arcing fault, the relay generates a fast tripping pulse, less than 1msec., to the circuit breaker(s) supplying the installation. The arcing time is thus reduced to the mechanical opening time of the circuit breaker, The relay is solid state with complete isolation between input and output. Thus the relay and the circuit breaker...
Open the catalog to page 3Arc-fault Protection D0500 Junction Box with Indication D0700 Overcurrent Relay For use with: · D0100 For use with: · D0100 · A0200 · A0300 The D0500 is designed to connect up to 8 detectors in parallel and has a separate indication of which detec-tor(s) caused tripping by means of a red LED for each detector. The red LED is lit when the light intensity exceeds 6.000lux. on the detector, but it turns off again if the intensity goes below 6.000lux. At 12.000lux. the arc detecting relay is triggered, the active LED’s are latched and a yellow LED (TRIP) is turned on. All LED’s remain turned on...
Open the catalog to page 4SELCO Arc-fault Protection System D0100 - Arc Detecting Relay DC Voltage Supply: Triac output: 250V AC/DC, 8A cont. 25A/ 0.1sec. Min. load current 50mA. Signal contacts: Response time: Power consumption: Light intensity from an arc current of min. 3kA detected inside of the curves will trip the breaker. Ambient temperature: D0500 - Junction Box with indication Power consumption: Ambient temperature: Voltage Supply: Current inputs: Current range: Response time: Power consumption: Ambient temperature: Thyristor output with stored energy: A0300, 360 degrees Voltage Supply: Storage capacitor 66...
Open the catalog to page 5SELCO Worldwide SELCO Subsidiary SELCO Representation and area of supply Main Office: SELCO A/S Betonvej 10 DK- 4000 Roskilde Denmark Phone: + 45 - 70 26 11 22 Fax: + 45 - 70 26 25 22 e-mail: selco.dk@selco.com www.selco.com Argentina Australia Austria Belgium Brazil Bulgaria Chile China Croatia Czech Republic Egypt Finland France Germany Greece Hong Kong Hungary Iceland India Indonesia Iran Italy Japan Korea Malaysia Morocco Netherlands New Zealand Norway Pakistan Philippines Poland Portugal Romania Russia Singapore South Africa Spain Sweden Taiwan Thailand Turkey Ukraine United Kingdom...
Open the catalog to page 6All Littelfuse catalogs and technical brochures
-
Fuse Fundamentals
20 Pages
-
INDUSTRIAL CIRCUIT PROTECTION
292 Pages
-
SURGE PROTECTIVE DEVICES
32 Pages
-
HIGH-SPEED SEMICONDUCTOR
72 Pages
-
Power Semiconductor & IC
133 Pages
-
Dc Disconnect Switches
2 Pages
-
ESR_Fuse_Datasheet
6 Pages
-
ELECTRICAL COILS
2 Pages
-
PRODUCTS FOR AGRICULTURE
36 Pages
-
CIRCUIT PROTECTION
15 Pages
-
MSL Classification
2 Pages
-
SE-325 SERIES (PGM-8325)
1 Pages
-
SE-CS10 SERIES
2 Pages
-
ECSW SERIES
3 Pages
-
LSR-0
1 Pages
-
LSRU SERIES
2 Pages
-
LSRX / LSRX-C SERIES
2 Pages
-
50R-400-ALT
1 Pages
-
ALT SERIES
2 Pages
-
05903300 & 05903500 RELAYS
1 Pages
-
05930100 & 05930800 RELAYS
1 Pages
-
05931300 & 05931600 RELAYS
1 Pages
-
QJxx30LH4 series
6 Pages
-
Thyristors QJ8012xHx Series
8 Pages
-
30KPA-HRA Series
7 Pages
-
AK1-Y Series
4 Pages
-
QJxx40xx Series
8 Pages
-
TS Series
11 Pages
-
Littelfuse SIDACtor Products Catalog
239 Pages
-
Electronic Fuse Products Catalog
409 Pages
-
Passenger Car Catalog
60 Pages
-
Polyfuse PPTC Catalog
128 Pages
-
POWRGARD Electrical Product Catalog
202 Pages
-
Protection Relays SSAC Catalog
524 Pages
-
Sensors Products Catalog
20 Pages
-
SIDACtor Catalog
239 Pages
-
TVS Diode Array (SPA) Catalog
215 Pages
-
Varistors Catalog
254 Pages
-
SOLAR PRODUCTS CATALOG
28 Pages
-
MP8000
2 Pages
-
MicroPlex® SSR18 AND SSR30
2 Pages
-
606 Series
3 Pages
-
ST Series
3 Pages
-
885 Series Fuse
3 Pages
-
MicroPlex® 7X, 7H, & 7L
2 Pages
-
TPSMB Series
6 Pages
-
TPSMD Series
6 Pages
-
ISOBUS SYSTEM
2 Pages
-
POLYFUSE®
6 Pages
-
Passenger Car Solutions
60 Pages
-
TVS Diode Catalog
174 Pages
-
Switching Thyristor Product Catalog
442 Pages
Archived catalogs
-
AFTERMARKET PRODUCTS CATALOG
136 Pages
-
AFTERMARKET PRODUCTS CATALOG 2018
132 Pages
-
Littelfuse Thyristor Catalog
467 Pages