video corpo

LSG-6000

LSG-6000
1 / 30 PagesView full catalog

LSG-6000

Product catalog summary
System Configuration
The LSG-6000 Goniophotometric System features a rotating console with precision components from Mitsubishi and German manufacturers, a high reflective moving mirror, and a control instrument housed in a 19-inch cabinet. It supports both Far Field and Near Field tests and includes an Android app for user-friendly control. The system is equipped with a Class L Constant Temperature Photo Detector and a cross-beam laser system for calibration. It includes English measuring software and three sets of luminaire clamps, with overseas delivery packaged in fumigation-free plywood.
Measurement Principle
The system adheres to LM-79-19 standards, measuring luminous intensity by keeping the lamp stationary while detectors move with a mirror. The software prioritizes rotation, enabling continuous measurement of luminous intensity at various angles.
System Functions
Compliant with LM-79-19, CIE, and GB standards, the system measures spatial luminous intensity distribution and other photometric parameters, including iso-intensity curves, luminance limitation curves, luminaire efficiency, and electric parameters.
Specifications
The system allows for precise luminaire rotation around the mirror and itself. It has a luminosity testing range of 0.001lx to 99,999lx and light intensity from 1.0cd to 107cd, with photometry accuracy ensured by a German constant temperature photo detector.
Laboratory Requirements
The dark room should be coated with dull black paint or covered with black cloth and carpet. The temperature must be controlled to 25℃±1℃, with specific exceptions for different lamp types. Airflow should not exceed 0.2m/s, and the environment must be free from smoke, dust, and moisture.
Service
LISUN GROUP offers installation and training, with a 24-month guarantee and free software upgrades.
Design Standard of Device
The LSG-6000 complies with various international standards, including CIE and IES standards for photometric testing.
Application Software
The system exports data in formats compatible with lighting design software like DiaLux and performs essential calculations for lighting design.
Test Report
The test report includes detailed photometric parameters, electric parameters, and light distribution curves, showcasing the system's capability for comprehensive lighting analysis.
Test Specifications
- Test Type: Type C
- Test Distance: 8.160 m
- C Plane (°): 0.0-180.0:1.0
- γ (°): 0.0-180.0:1.0
- Test Device: Lisun LSG-6000 (E312012J)
- Temperature: 25.0°C
- Humidity: 65.0%
- Test Lab: LISUN Lab
- Test By: David
- Report No.: 5
- Test Time: 2021-04-02 15:13:16
Light Distribution Data
The document provides detailed light distribution data across various gamma angles and C planes, presented in candela (cd) units, illustrating how light intensity varies with angle.
Zonal Flux Data
The zonal flux data is presented in terms of gamma angles, showing the mean intensity, zonal flux, and relative zonal flux in lumens and percentage.
Key Observations
- Light intensity generally decreases as the gamma angle increases.
- Data consistency across different C planes indicates uniform light distribution.
See more

Catalog excerpts

LSG-6000-1

Moving Detector Goniophotometer (LSG-6000) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK Tel: 00852-68852050 Fax: 00852-30785638 Email: [email protected] Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: [email protected] Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: [email protected] Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: [email protected] Leader in Lighting & Electrical Test Instruments Rev. 5/21/2021

 Open the catalog to page 1
LSG-6000-2

1. System Configuration A. LSG-6000 Goniophotometric System:  Goniometric Rotating Console: Japanese Mitsubishi Motor and German Angle encoder System to keep the test accuracy. Both Far Field and Near Field Test.  High Reflective Moving Mirror: Special design and produced to keep high reflective value.  Goniometric Rotating Control Instrument in 19inch cabinet: It connects to the PC and was controlled by the software.  It has Goniometric Rotating Control Android App which can control it to rotating angle in the dark room easily  Far Field and Near Field applied with Germany produced Class...

 Open the catalog to page 2
LSG-6000-3

2. Measurement Principle LSG-6000 Moving Detector Goniophotometer is full meet LM-79-19 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries. The rotation priority is determined by the software. If mirror axle is took precedence of rotation, the goniophotometer will continuously measure the luminous intensity at each γ angle on a vertical plane determined by the C angle, the measuring...

 Open the catalog to page 3
LSG-6000-4

The LSG-6000 full meet LM-79-19, CIE and GB standards for Goniophotometric of luminaries, this system is used to measure spatial luminous intensity distribution of luminaries for floodlight, street lighting and interior lighting, and other photometric parameters such as spatial iso-intensity curve, intensity distribution curve of each section (shown in rectangular coordinate system or polar coordinate system), iso-illuminance distribution curve, luminance limitation curve, luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio, downward luminous flux ratio, total...

 Open the catalog to page 4
LSG-6000-5

Room Requirements according to CIE The max size for the Testing Lamp(Unit: mm) LISUN MODEL C-Gamma Test with one Pillar (Diameter E* Depth F) B-Beta Test with two Pillars (L*W) Testing Weight Table 1 The Diamensions of the Goniophotometer Master Figure 1 The Side View  Figure 2 The Vertical View The dark room wall, ceiling and floor should be all coated with dull black paint or be covered by black cloth and black carpet. Air-conditioner: be set in the dark room to control the temperature around lamps to the standard value upon the CIE requirements. Note: LISUN GROUP engineer dept will submit...

 Open the catalog to page 5
LSG-6000-6

Fig: LSG-6000 lab dark room view Requirements of Eliminating the stray Light Luminaires must be where the photo detector can only receive the light reflected by the two moving mirror in the LSG-6000 system. The light given off directly by the luminaries and reflected by the wall and floor is warded off by the light fence. Internal surface of the dark room and dark path together with the surface of the light fence should be painted unpolished black or be covered by black cloth and black carpet. 3) Temperature around the lamp or luminaries must be 25℃±1℃ during the test. Exceptions can be given...

 Open the catalog to page 6
LSG-6000-7

Airflow may be induced by natural aeration, air conditioner or movement of the luminaries in the goniophotometer, but the speed of the airflow couldn’t exceed 0.2m/s. 5) When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~ 3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most 4Hz) 6) Smoke, Dust and Moisture The test environment must free from smoke, dust or moisture. At the same time, even not during the measurement, smoke, dust or moisture will also influence the reflectance of the reflecting mirror and induce more stray light. So, the test room must be kept...

 Open the catalog to page 7
LSG-6000-8

8. Typical oversea market customers: There are many world famous company and lab institute choose Lisun Goniophtometer, Please get the reference customers’ information from Lisun Group Oversea Sales Dept. 9. Application Software This system can export data files as following formats: This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Application software can also implement essential calculation for lighting design as iso-illuminance distribution curve on a working plane, luminance limitation curve, luminaire efficiency, effective beam...

 Open the catalog to page 8
LSG-6000-9

Fax:+86(21)51083342 Tel:+86(21)51083341 Lisun Instruments Limited www.Lisungroup.com Report No. : 5 Lisun Goniophotometer Test Report Product Info Luminaire Category : Indoor LED Lamp : cree Manufacturer : Philips Lighting B.V. Submitter : Michael Aslami Nuber of Lamps : 1 Lumens per Lamp : 2100 lm Luminous Length : 100 mm Luminous Width : 100 mm Electric Parameters Voltage : 229.80 V Power Factor : 0.938 Frequency : 50.06 Hz Photometric Parameters CIE Class : Direct Measurement Flux : 1942.7 lm Upward Ratio : 6.67 % Maximum Intensity : 663.61 cd Central Intensity : 663.51 cd Luminaire Efficacy...

 Open the catalog to page 9
LSG-6000-10

Fax:+86(21)51083342 Tel:+86(21)51083341 Lisun Instruments Limited www.Lisungroup.com Report No. : 5 Light Distribution Curve 140 Test Type : Type C Test Distance : 8.160 m Test Device : Lisun LSG-6000 (E312012J) Test Lab : LISUN Lab Test By : David C Plane (°): 0.0-180.0:1.0 Temperature : 25.0°C Review By :

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.