LSG-2000

LSG-2000
1 / 35 PagesView full catalog

LSG-2000

Product catalog summary
System Configuration
The LSG-2000 Goniophotometric System is equipped with a rotating console featuring a Mitsubishi motor and a German angle encoder for precision. It includes a high reflective moving mirror, a control instrument for PC connection, a double channel photometer, a constant temperature photo detector, and a cross-beam laser system for calibration. The system supports English measuring software and automatic diaphragm adjustment for various luminaire sizes, and comes with necessary accessories including luminaire clamps.

Measurement Principle
The system tests luminaires by rotating them and a mirror around a horizontal axis. The photometer head collects light from different directions, measuring luminous intensity at various angles based on software-determined rotation priorities.

System Functions
The LSG-2000 adheres to LM-79, CIE, and GB standards, measuring spatial luminous intensity distribution and other photometric parameters such as iso-intensity curves, luminance limitation curves, and luminaire efficiency.

Specifications
The system allows precise luminaire rotation with high angle accuracy and resolution, supports a wide luminosity testing range, and uses a constant temperature photo detector for accurate photometry. It is compatible with Windows 7, 8, and 10.

Laboratory Requirements
Dark rooms must meet specific size and environmental conditions, including temperature control and elimination of stray light. The environment should be free from smoke, dust, and moisture, with controlled airflow and minimal vibration.

Service
LISUN GROUP offers installation and training, a 24-month guarantee, and free software upgrades.

Design Standard of Device
The LSG-2000 complies with international photometric testing standards, including CIE and IES standards.

Application Software
The system exports data in formats compatible with lighting design software and performs essential calculations for lighting design.

Test Report
A sample test report is included, detailing photometric results such as luminous intensity distribution curves and coefficients of utilization.
See more

Catalog excerpts

LSG-2000-1

Goniophotometer with Moving Mirror (LSG-2000) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK Tel: 00852-68852050 Fax: 00852-30785638 Email: [email protected] Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: [email protected] Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: [email protected] Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: [email protected] Leader in Lighting & Electrical Test Instruments Rev. 1/16/2020

 Open the catalog to page 1
LSG-2000-2

1.System Configuration A. LSG-2000 Goniophotometric System:  Goniometric Rotating Console: Japanese Mitsubishi Motor and German Angle encoder System to keep the test accuracy.  High Reflective Moving Mirror: Special design and produced to keep high reflective value.  Goniometric Rotating Control Instrument in 19inch cabinet: It connects to the PC and was controlled by the software.  Goniometric Rotating Control Instrument in dark room: This can allow the customer to control the rotating in the dark room when install the lumainires but no need to control in the PC.  Double Channel & High...

 Open the catalog to page 2
LSG-2000-3

2. Measurement Principle Goniophotometer with Moving Mirror (also called Goniphotometer with Rotating Mirror) can test luminaries rotating in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The photometer head located at a fixed position of the limiting photometric distance in front of the reflecting mirror to gather the light in each direction. The rotation priority is determined by the software. If mirror axle is took precedence of rotation,...

 Open the catalog to page 3
LSG-2000-4

The LSG-2000 fully meet LM-79 Clause 9.3.1, CIE and GB standards for Goniophotometric of luminaries, this system is used to measure spatial luminous intensity distribution of luminaries for floodlight, street lighting and interior lighting, and other photometric parameters such as spatial iso-intensity curve, intensity distribution curve of each section (shown in rectangular coordinate system or polar coordinate system), iso-illuminance distribution curve, luminance limitation curve, luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio, downward luminous flux...

 Open the catalog to page 4
LSG-2000-5

Room Requirements according to CIE Operation Room(W*L) The dark room wall, ceiling and floor should be all coated with dull black paint or be covered by black cloth and black carpet. Air-conditioner: be set in the dark room to control the temperature around lamps to the standard value upon the CIE requirements. Note: LISUN GROUP engineer dept will submit the Lab Design support documents according to the customer’s real lab size after the formal purchase order was confirmed Fig: LSG-2000 lab dark room view

 Open the catalog to page 5
LSG-2000-6

Requirements of Eliminating the stray Light Luminaires must be where the photodetector can only receive the light reflected by the rotating mirror in the LSG-2000 system. The light given off directly by the luminaries and reflected by the wall and floor is warded off by the light fence. Internal surface of the dark room and dark path together with the surface of the light fence should be painted unpolished black or be covered by black cloth and black carpet. 3) Temperature around the lamp or luminaries must be 25℃±1℃ during the test. Exceptions can be given according to relative lamps as following....

 Open the catalog to page 6
LSG-2000-7

7. Design Standard of Device The construction, technical parameter, test & operate steps as well as data processing software of LSG-2000 Goniophotometer with Moving Mirror meet the following requirements: 3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity Distributions” 3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires” 3.3 IES LM-35-1989,”IES Approved Method for Photometric Floodlights” 3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway Luminaires” 3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products” 3.6 GB/T 7002-1986,“Luminosity...

 Open the catalog to page 7
LSG-2000-8

Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: LS1127 Luminaire Property Luminaire Manufacturer: W.K.LIGHTING Luminaire Category: WK-71-83-8077-85-IP65 Lamp Catalog: LUMINUS Lamp Description: Philips Number of Lamps: 1 Lumens per Lamp: 700 Luminous Length (mm): 8.5 Luminous Width (mm): 8.5 Luminous Height (mm): 12 Voltage: 220.6 V Current: 0.071 A Power: 8.69 W Power Factor: 0.559 Photometric Results CIE Class: Direct Measurement Flux: 641.8 lm Downward Ratio: 91.69% Horizontal Diffuse Angle(50%): H34.6 Vertical Diffuse Angle(50%): V34.1...

 Open the catalog to page 8
LSG-2000-9

Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 C Plane (°):0.0-360.0: 22.5 Test Lab: LISUN Test Type: TYPE C Temperature: 24.5 Operator: Joye Unit: cd Gamma Plane (°):0.0-90.0:1.0 Test Device: LSG-2000 Distance: 8.300 m Humidity: 60% Inspector:

 Open the catalog to page 9
LSG-2000-10

Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Luminous Intensity Distribution Curve(cd/klm) 160 C Plane (°):0.0-360.0: 22.5 Test Lab: LISUN Test Type: TYPE C Temperature: 24.5 Operator: Joye Gamma Plane (°):0.0-90.0:1.0 Test Device: LSG-2000 Distance: 8.300 m Humidity: 60% Inspector

 Open the catalog to page 10
LSG-2000-11

Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Curves of Luminaires vs Lighting Area 8 =5 =7 6 H= = HH H 0 =1 Luminous Flux Maintain Factor Suspend Length Work Height Average Lux Line Type C Plane (°):0.0-360.0: 22.5 Test Lab: LISUN Test Type: TYPE C Temperature: 24.5 Operator: Joye Gamma Plane (°):0.0-90.0:1.0 Test Device: LSG-2000 Distance: 8.300 m Humidity: 60% Inspector:

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.