High Precision Rotation Luminaire Goniophotometer (LSG-1890B/LSG-1800A) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Leader in Lighting & Electrical Test Instruments Rev. 5/21/2021

Open the catalog to page 1
LSG-1890B - 2

System Configuration A. Goniophotometric System:  Goniometric Rotating Console: 1) LSG-1890B: Japanese Mitsubishi Motor and German Angle encoder System to keep the test accuracy to 0.1degree 2) LSG-1800A: Taiwan Motor and Angle encoder System to keep the test accuracy to 0.2degree  The LSG-1890B has Goniometric Rotating Control Instrument in 19inch cabinet: It connects to the PC and was controlled by the software.  The LSG-1890B/LSG-1800A has Goniometric Rotating Control Android App which can control it to rotating angle in the dark room easily.  High Precision Photometer with Class A...

Open the catalog to page 2
LSG-1890B - 3

2. Working Principle Goniophotometric System carries out measuring methods of fixed location and rotating luminaries. The measured luminaries is installed on the rotating supported, the center of which is in line with the rotating supporter center with the help of Laser sight. The fixed photometry detector is testing the luminous intensity in various horizontal directions, while the light source rotating. The mechanical equipment allows turning the tested luminaries around a vertical axis and a horizontal axis. When the luminaries under test turn around horizontal axis, the detector which...

Open the catalog to page 3
LSG-1890B - 4

3. System Functions LSG-1890B/LSG-1800A Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1890B uses a constant temperature detector, Japanese Motor and Germany precision angle coder which keep high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries. Be utilized to measure photometric parameters of luminaries for LED road lighting fixture, room lighting fixture and projecting lighting fixture, such as spatial intensity...

Open the catalog to page 4
LSG-1890B - 5

Meets the requirements of CIE, IEC, IES LM-79 & GB standards Reaching many measurement ways such as B-βand C-γ Test Max Luminaires size and weight: LSG-1890B is 1900mm/60kg and LSG-1800A is 1600mm/50kg The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0-360°) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~107cd(detector) Photometry Accuracy: CIE Class A (Class L is option) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% English version...

Open the catalog to page 5
LSG-1890B - 6

L=6*E (According to CIE, it requests at least 6times than the testing lamps).  Control Room size request: min=2000*2000*2000mm The wall, ceiling and floor should be all coated with dull black paint or be covered by black cloth and black carpet. Air-conditioner should be set in the dark room to control the temperature around lamps to the standard value upon the CIE requirements LISUN engineer dept will submit the Lab Design support documents according to the customer’s lab size after the purchase order was confirmed (The below are two Typical Lab Design reference for LSG-1890B/LSG-1800A)

Open the catalog to page 6
LSG-1890B - 7

6. Typical oversea market customers: --------------------------------------------------------------------------------------------------- There are many world famous companies and lab institute choose Lisun Goniophtometer, Please get the reference customers’ information from Lisun Group Oversea Sales Dept. 7. Design Standard of Device The construction, technical parameter, test & operate steps as well as data processing software of goniophotometer meet the following requirements:  CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity Distributions” IES LM-35-1989,”IES Approved...

Open the catalog to page 7
LSG-1890B - 8

8. Application Software All control of the goniophotometer operations can be realized by the software, including gonophotometer movement, data acquisition and processing, real-time display on screen, report print and etc, thus enabling the measurement easy and secure. This system can export data files as following formats: This kind of format files can be transferred by other illumination and luminaries design software such as DiaLux Application software can also implement essential calculation for lighting design as iso-illuminance distribution curve on a working plane, luminance...

Open the catalog to page 8
LSG-1890B - 9

Fax:+86(21)51083342 Tel:+86(21)51083341 Lisun Instruments Limited www.Lisungroup.com Report No. : 3 Lisun Goniophotometer Test Report Product Info Luminaire Category : Indoor LED Lamp : cree Manufacturer : Philips Lighting B.V. Submitter : Michael Aslami Nuber of Lamps : 1 Lumens per Lamp : 2100 lm Luminous Length : 100 mm Luminous Width : 100 mm Electric Parameters Voltage : 229.80 V Power Factor : 0.938 Frequency : 50.06 Hz Photometric Parameters CIE Class : Direct Measurement Flux : 1942.7 lm Upward Ratio : 6.67 % Maximum Intensity : 663.61 cd Central Intensity : 663.51 cd Luminaire...

Open the catalog to page 9
LSG-1890B - 10

Fax:+86(21)51083342 Tel:+86(21)51083341 Lisun Instruments Limited www.Lisungroup.com Report No. : 3 Light Distribution Curve 140 Test Type : Type C Test Distance : 8.160 m Test Device : Lisun LSG-1890B (E312012J) Test Lab : LISUN Lab Test By : David C Plane (°): 0.0-180.0:1.0 Temperature : 25.0°C Review By :

Open the catalog to page 10