Catalog excerpts
page 1 PH Classic-Series “Village” Genset PHV 5, PHV 10 Standard Features „X Lister Petter PH Classic-Series, air-cooled, direct injection, naturally aspirated diesel engine „X 12V electric start „X single-bearing, 4-pole brushless alternator „X mechanical regulation „X flywheel-mounted cooling fan „X control panel, mounted on alternator „X 66-litre polypropylene fuel tank with contents gauge „X galvanised steel base-plate with forklift pockets and bunding for the fuel tank „X medium-duty dry-type air cleaner „X engine-mounted industrial silencer „X anti-vibration mountings „X electrical diagrams „X Operators’ Handbook Optional Item „X handle-starting (not anti-kick back) Easy maintenance air-cooled generating set Handstart Genset Power Outputs 50 Hz 1500 r/min Single Phase Three Phase Model Engine Rating kVA kW kVA kW PHV 5 PH1 Prime 5.0 5.0 5.0 4.0 Standby 5.5 5.5 5.5 4.4 PHV 10 PH2 Prime 10.0 10.0 10.0 8.0 Standby 11.0 11.0 11.0 8.8 Rating Definitions to ISO 8528-1 All ratings in the table are in accordance with ISO 8528-1. Power Factor: Single phase, 1.0 pf; three-phase, 0.8 pf. Voltages: Single phase 220, 230, 240; three phase 380/220V, 400/230, 415/240. 50 Hz. Single phase 220/110, 230/115, 240/120; Three phase 220/127, 230/133. 60 Hz. Other voltages are available; refer to Lister Petter. Power outputs are based on the optimum make of alternator for the set. Gensets fitted with other manufacturers’ alternators may not achieve the above ratings. Rating Conditions A standard generating set is designed to operate in environmental reference conditions of 25 °C, 100 kPa and 30% humidity. Prime Power This rating is for the supply of continuous electrical power (at variable load). There is no limit on the annual hours of operation and 10% overload power can be supplied for 1 hour in 12. Standby Power This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted. kVA, 50 Hz
Open the catalog to page 1page 2 Air-Cooled Handstart Generating Set: Approximate Dimensions and Weight Open generating set model: PHV 5 PHV 10 Open Set: side elevation (left); end elevation (right) Dry weight kg 370 450 lb 816 992 Length (A) mm 1400 1400 in 55.1 55.1 Width (B) mm 715 715 in 28.1 28.1 Height (C) mm 1248 1248 in 49.1 49.1 PH Classic-Series: “Village” Genset Technical Data Sheet Lister Petter have made efforts to ensure that the information in this data sheet is accurate but reserve the right to amend specifications and information without notice and without obligation or liability. P027-08532,...
Open the catalog to page 2All LISTER PETTER catalogs and technical brochures
-
TR Engines
44 Pages
-
LPW/LPWS/LPWX ENGINE
40 Pages
-
ALPHA MARINE ENGINES
3 Pages
-
TR MARINE ENGINES
2 Pages
-
GW4 - 22
2 Pages
-
LPW ENGINES
4 Pages
-
LWA High Speed Gas Genset
5 Pages
-
LWA Slow Speed Gas Genset
5 Pages
-
K Max 6 Gensets
2 Pages
-
K Max 10 Gensets
2 Pages
-
K Max 5 Gensets
2 Pages
-
LPWX3 G BUILD ENGINE
2 Pages
-
LPWX2 G BUILD ENGINE
2 Pages
-
LPWX4 G BUILD ENGINE
2 Pages
Archived catalogs
-
LLS Water-Cooled Gensets
4 Pages
-
Air-Cooled Genset
2 Pages
-
LLD Water-Cooled Gensets
4 Pages
-
LISTER-PACK Series
2 Pages
-
OMEGA 200 G-Build
3 Pages
-
GW4 G-Build Engine
4 Pages
-
DWS4 Engine
4 Pages
-
G-Build Engine
2 Pages
-
TR2 G-Build Engine
2 Pages
-
LV1
4 Pages
-
TR3 G-Build Engine
2 Pages
-
TR1 G-Build Engine
2 Pages
-
AC and AD Engines
4 Pages
-
ALPHA BIO
4 Pages