Basic Characteristics:
The K-Max 10 Water Cooled Gensets are CE approved, operating at 50Hz and 3000rpm, with power outputs ranging from 10.0 to 13.75kVA. They are designed for light duty, portable, and emergency power applications, featuring a V-Twin water-cooled diesel engine and Bosch fuel gear. The gensets include marine/tropical grade alternator winding protection and a Deep Sea remote/2-wire start control panel suitable for inverter or AMF signal.
Standard Features:
The gensets come with a top-opening easy access acoustic canopy, corrosion-resistant zirconium phosphate treated steel, and a robust ripple effect scratch-resistant powder-coated canopy finish. They have a 12V electric starting system, naturally aspirated diesel engine, single bearing, 2-pole alternator with AVR, and a panel-mounted coolant temperature gauge. The fuel tank has a 45-litre capacity with a panel-mounted electronic contents gauge, and there is easy access to an in-line fuel filter. Additional features include A-class mechanical governing, a 12V starter battery and leads, an operator handbook, and country-specific socket outputs.
Control Panel Features:
The standard control panel includes a key switch, back-lit icon LCD display, LED and LCD alarm indication, USB configurability, configurable timers and alarms, remote start input, generator voltage display, battery voltage display, engine speed display, hours counter, and comprehensive shutdown or warning on fault condition.
Technical Data:
The gensets are suitable for light duty and emergency duty applications, with specific ratings for each. Light duty is for portable and intermittent applications, with an average load between 40% and 80%, not exceeding 3 hours of continuous use or 300 hours annually. Emergency duty is for utility power outages, with no overload capability and an annual operation limit of 200 hours. Derating factors apply for ambient temperatures over 25°C and altitudes over 100m.
Fuel Consumption and Sound Pressure:
Fuel consumption varies with load, with 3.5 litres per hour at 100% load, decreasing to 1.4 litres per hour at 40% load. The sound pressure level is 70 dB(A) at 7m with 75% load.
Dimensions and Weight:
The LWK10A model measures 1300mm in length, 740mm in width, and 880mm in height, with a dry weight of 280 kg.
Power Outputs:
For single-phase, 220-240V, the light duty rating is 10.0 kVA/kWe, and the emergency rating is 11.0 kVA/kWe. For three-phase, 400/230V, the light duty rating is 12.5 kVA and 10.0 kWe, and the emergency rating is 13.75 kVA and 11.0 kWe.
Options:
Optional features include a wireless remote push button start and a remote/wall-mounted mains sensing automatic transfer switch (ATS) with a static battery charger. The ATS includes Schneider contactors and ratings of 50 amp single phase and 25 amp three phase, with a 3-meter plug-in loom for remote start signal and battery charging current.
See more

Catalog excerpts

K Max 10 Gensets-1

K-MAX 10 WATER COOLED GENSETS LWK10A Series II CE Approved; 50Hz; 3000rpm; power outputs: 10.0-13.75kVAWATER COOLED GENERATING SETS BASIC CHARACTERISTICS • 50Hz, 3000 rpm, single or three phase • designed for light duty, portable and emergency power applications • V-Twin water cooled diesel engine • Bosch fuel gear • marine / tropical grade alternator winding protection • Deep Sea remote / 2-wire start control panel suitable for inverter or AMF signal standard features • top opening easy access acoustic canopy • corrosion resistant zirconium phosphate treated steel • robust ripple effect scratch resistant powder coated canopy finish • 12V electric starting system • naturally aspirated diesel engine single bearing, 2-pole alternator with AVR panel mounted coolant temperature gauge 45-litre fuel tank with panel mounted electronic contents gauge easy access in-line fuel filter A-class mechanical governing 12V starter battery and leads operator handbook 2 socket outputs (country specific) - single phase 1 x 32amp and 1 x 10amp socket - three phase 1 x 32amp and 1x 10amp single phase socket outlet plugs to suit sockets 24 months conditional warranty (see operator handbook) STANDARD Control Panel FEATuRES • key switch • back-lit icon LCD display • LED and LCD alarm indication • USB configurable • configurable timers and alarms • remote start input • generator voltage display • battery voltage display • engine speed display • hours counter • comprehensive shutdown or warning on fault condition

 Open the catalog to page 1
K Max 10 Gensets-2

OPTIONS • wireless remote push button start • remote / wall mounted mains sensing automatic transfer switch (ATS) with static battery charger, 50 amp single phase, 25 amp three phase K-MAx ATS • Schneider contactors • 50 amp single phase rating, 25 amp three phase rating • 3 meter plug in loom provided between ATS and K-Max genset for remote start signal and battery charging current APPROXIMATE WEIGHT AND DIMENSIONS 50 Hz, 3000 r/min, single phase, 220-240V 1. Light Duty Light duty rating is applicable for supplying power in portable and/ or intermittent applications. The average load should...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.