DELTA Series LLD Water-Cooled Genset
4Pages

{{requestButtons}}

Catalog excerpts

DELTA Series LLD Water-Cooled Genset - 1

page 5 1 DELTA Series LLD Water-Cooled Genset LLD 410 50 Hz; 1500 r/min; power outputs: 33 kVA 60 Hz; 1800 r/min; power outputs: 39 kVA Water-cooled mounted genset with electronic control module Acoustic Sets Only: „X acoustic canopy „X residential exhaust silencer „X external emergency stop button Open Set (LLD 410) Choice of: ƒÀ 50 Hz, 1500 r/min or 60 Hz, 1800 r/min ƒÀ Lister Petter DELTA Series water-cooled engine ƒÀ open set (LLD 410) or acoustic set (LLD 410A) Standard Features „X control system with electronic digital control module (for features see page 3) „X single-bearing, 4-pole brushless alternator „X 95-litre integral fuel tank with contents gauge „X black steel base-plate „X anti-vibration mountings „X 12 V starter battery and leads „X mechanical governing „X output circuit breaker „X emergency stop button (lock-down type) „X high engine temperature and low oil pressure shutdown system „X pusher fan „X Operators’ Handbook „X electrical diagram Open Sets Only: „X engine-mounted exhaust silencer Acoustic Set (LLD 410A)

Open the catalog to page 1
DELTA Series LLD Water-Cooled Genset - 2

page 2 Rating Definitions to ISO 8528-1 All ratings are in accordance with ISO 8528-1. Rating Conditions A standard generating set is designed to operate in environmental reference conditions of 25 °C, 100 kPa and 30% humidity. Prime Power This rating is for the supply of continuous electrical power (at variable load). There is no limit on the annual hours of operation and 10% overload power can be supplied for 1 hour in 12. Standby Power This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted. LLD...

Open the catalog to page 2
DELTA Series LLD Water-Cooled Genset - 3

page 3 Control Cubicle All LLD and LLDA sets have a control cubicle mounted on a vibration-isolated support, which has the following features: „X electronic digital control module with monitoring/control facility and warning indicators „X automatic shutdown protection „X emergency stop button (lock-down type) „X AC output circuit breaker with over-current protection „X DC circuit control switch and overload circuit breaker The control module gives digital readouts of: „X generator voltage (phase-to-phase and phase-to-neutral) „X generator current (each phase displayed separately) „X output...

Open the catalog to page 3
DELTA Series LLD Water-Cooled Genset - 4

page 4 P027-08521, July 2009 LLD (DELTA) Water-Cooled Genset Technical Data Sheet A comprehensive range of options allows you to select a specification that matches your requirements. Please ask your Lister Petter distributor. (See panel below left.) Lister Petter have made efforts to ensure that the information in this data sheet is accurate but reserve the right to amend specifications and information without notice and without obligation or liability. Distributor’s Address UK Lister Petter Limited, Dursley, Gloucestershire GL11 4HS England; Tel: +44 (0)1453 544141; Fax: +44 (0)1453...

Open the catalog to page 4

All LISTER PETTER catalogs and technical brochures

  1. TR Engines

    44 Pages

  2. GW4 - 22

    2 Pages

  3. LPW ENGINES

    4 Pages

Archived catalogs

  1. DWS4 Engine

    4 Pages

  2. LV1

    4 Pages

  3. ALPHA BIO

    4 Pages