THERMOGRAVIMETRIC ANALYZER

Open the catalog to page 1
Thermogravimetric Analyzer - 2

Since 1957 LINSEIS Corporation has been delivering outstanding service, know how and leading innovative products in the field of thermal analysis and thermo physical properties. We are driven by innovation and customer satisfaction. Customer satisfaction, innovation, flexibility and high quality are what LINSEIS represents. Thanks to these fundamentals our company enjoys an exceptional reputation among the leading scientific and industrial organizations. LINSEIS has been offering highly innovative benchmark products for many years. Claus Linseis Managing Director The LINSEIS business unit...

Open the catalog to page 2
Thermogravimetric Analyzer - 3

German engineering The strive for the best due diligence and ac- We want to deliver the latest and best tech- countability is part of our DNA. Our history is af- nology for our customers. LINSEIS continues fected by German engineering and strict quality to innovate and enhance our existing thermal analyzers. Our goal is constantly develop new technologies to enable continued discovery in Science.

Open the catalog to page 3
Thermogravimetric Analyzer - 4

SIMULTANEOUS THERMAL ANALYSIS Simultaneous TGA-DTA/DSC measures both, of the results. The complimentary information heat flow and weight change of a sample as a obtained allows differentiation between endo- function of temperature or time under control- thermic and exothermic events which have no led atmosphere. Simultaneous measurement of associated weight change (e.g., melting and cry- these two material properties not only improves stallization) and those which involve a weight productivity but also simplifies interpretation High precision beam balance Sample holder Beam Counter weight...

Open the catalog to page 4
Thermogravimetric Analyzer - 5

DSC- True Heat Flow measurement Quantitative DSC-signal Reference signal Sample signal Time (s) Ts = sample temperature Tr = reference temperature Differential Scanning Calorimetry (DSC) “A technique in which the difference in energy input into a substance and a reference material is measured as a function of temperature, while the substance and reference material are subjected to a controlled temperature program.” Differential Signal The differential signal is displayed as a baseline. Effects, for example the melting of a metal, can be observed as a peak. The area of the peak gives the...

Open the catalog to page 5
Thermogravimetric Analyzer - 6

SENSORS Our TGA can be equipped with an unmatched Each sensor is available with different thermo- amount of different user exchangeable TG-DSC, couples to provide the highest sensitivty for your desired temperature range. Al2O3 Platinum Aluminium others DSC Heat flux 3D-Calvet-DSC sensor custom volume Different crucibles available / broad variety Crucible DTA-sensor

Open the catalog to page 6
Thermogravimetric Analyzer - 7

custom volume TG-hang- down wire TG-sample holders for many different applications Best possible sensitivity for your application Electromotive force / Temperature All sensors available with the thermocouples illustrated. LINSEIS Senosor combinations cover the broadest temeprature range in the market (-180 up to 2400°C).

Open the catalog to page 7
Thermogravimetric Analyzer - 8

Vacuum and controlled atmosphere The balance design provide for high vacuum, inert, reducing, oxidiz ing or humidified atmosphere. Furthermore, the instrument can be pressurized up to 5 bar overpressure (option). Certain corrosive conditions can be analyzed with proper precautions. The system is capable of adapting residual gas analysis systems using an optional heated capillary. Evolved gas analysis Optional gas analysis with MS, FTIR or GCMS is possible. This provides valuable additional information. Sample robot OurTGA PT 1000 and 1600 can be equiped with a proven sample robot for...

Open the catalog to page 8
Thermogravimetric Analyzer - 9

Starter kit The starter kit includes a variety of tool such as scissors, cutting tools, anti electrostatic tweezers, magnifier, crucible holder, pipette, rasps, spatula etc. Oxygen Getter Material OGM The LINSEIS oxygen getter system (OGM) can be placed in any LINSEIS system as a modification of the sample gas capillary. It is used to getter smallest traces of residual oxygen in the sample chamber by offering a stronger oxygen affinity than sample materials, combined with a high effective surface to ensure the oxygen molecules react with the getter before they have a chance to get in touch...

Open the catalog to page 9
Thermogravimetric Analyzer - 11

Benefits of the vertical top loading design The vertical "sample on top" design of the ble accuracy due to a stable position of the sam-LINSEIS thermobalance provides highest possi- ple and easy sample handling. Vertical system (sample on top) LINSEIS configuration Advantages: • Easy sample handling • Easy exchange of sample holder • Stable position of the sample in the furnace (critical for good DTA/DSC and Cp results) Disadvantage: • Complicated construction Horizontal system Advantages: • Small buoyancy effects Disadvantages: • Sensor exchange very difficult • Sample handling difficult •...

Open the catalog to page 11
Thermogravimetric Analyzer - 13

The highest resolution 0.025 µg balance for The high mass variant allows measuring samp- small sample quantities allows the detection of les with big volumes or weight 35/50g to deter- very small effects with highest accuracy. mine even small effects within a big amount of inhomogeneous material. TGA PT 1600/2 The standard model covers a broad application range with excellent resolution 0.1 µg and accuracy.

Open the catalog to page 13
Thermogravimetric Analyzer - 14

All LINSEIS thermo analytical instruments are PC controlled. The individual software modules run exclusively under Microsoft® Windows® operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The Windows® software incorporates all essential features for measurement preparation, execution, and evaluation of a thermoanalytical measurement. Thanks to our specialists and application experts, LINSEIS was able to develop comprehensive easy to understand user friendly application driven software. Features-Software: • Program capable...

Open the catalog to page 14
Thermogravimetric Analyzer - 15

Thermal Library The LINSEIS Thermal Library software package The Thermal Library allows you the comparison comes as an option for the well-known, user of the complete curves with a data base provi- friendly LINSEIS Platinum evaluation software ding thousands of references and standard ma- that is integrated in almost all our instruments. terials within only 1-2 seconds. rial Mate tion tifica Iden ion gnit reco m urve on syste c DSC retati p inter Measured and matching reference curves (green) and reference curves with poor fit (red). Our software is available in many different etc. can be...