Magnetic Suspension Balance - MSB PT1
6Pages

{{requestButtons}}

Catalog excerpts

Magnetic Suspension Balance - MSB PT1 - 1

Magnetic Suspension Balance

Open the catalog to page 1
Magnetic Suspension Balance - MSB PT1 - 2

LINSEIS MSB - PT1 With the magnetic suspension balance gravimetric measurements in a wide temperature and pressure range and under aggressive media can be done. Such a magnetic suspension balance consist of a balance for recording the measurement values, a suspension coupling which carries the weight of the sample, a sensor for the position measurement of the levitation part and a control unit to control the suspension coupling. The contact-less transmission of the sample weight is realized with a levitation magnet and a holding magnet. The levitation magnet consists of a permanent magnet...

Open the catalog to page 2
Magnetic Suspension Balance - MSB PT1 - 3

Heater Temperature Pressure

Open the catalog to page 3
Magnetic Suspension Balance - MSB PT1 - 4

Technical Specifications Model Metal Version Glass Version Pressure Range UHV to 350 bar Vacuum to 1.3 bar Temperature Range -196 to 2400°C Up to 900°C Evolved Gas Analysis MS/FTIR possible MS/FTIR possible Special custom versions can be realized. Metal version The metal version can be used for a wide application area. Measurements from ultra high vacuum up to 350 bar and a temperature range from -196 to 2400°C are possible. Furthermore corrosive and toxic media are insertable. This will be possible with special coatings of the metal measurement cell. Glass version For the...

Open the catalog to page 4
Magnetic Suspension Balance - MSB PT1 - 5

–150 Stop water vapor Start water vapor with 0.4 ml/min A common known application for HDSC measurements is the investigation of the so called coal gasification or hydro gasification. This process, where carbon is heated in a water steam atmosphere is used in some catalytical processes, for example to remove carbon monoxide (CO) from exhaust fumes and especially to get valuable organic compounds out from resources like charcoal or biomass. The whole process can be described like this: Charcoal or the Carbon parts of Biomass react with water vapour to a mixture of carbon monoxide and...

Open the catalog to page 5
Magnetic Suspension Balance - MSB PT1 - 6

LINSEIS GmbH Vielitzerstr. 43 95100 Selb Germany Tel.: (+49) 9287–880 - 0 Fax: (+49) 9287–70488 E-mail: info@linseis.de LINSEIS Inc. 109 North Gold Drive Robbinsville, NJ 08691 USA Tel.: (+1) 609 223 2070 Fax: (+1) 609 223 2074 E-mail: info@linseis.com LINSEIS France Bureaux Paris 52 Boulevard Sébastopol 75003 Paris Tel.: (+33) 173-028 272 www.linseis.com Products: DIL, TG, STA, DSC, HDSC, DTA, TMA, MS/FTIR, In-Situ EGA, Laser Flash, Seebeck Effect, Thin Film Analyzer, Hall-Effect Services: Service Lab, Calibration Servi

Open the catalog to page 6

All Linseis Thermal Analysis catalogs and technical brochures

  1. LZT

    9 Pages

  2. L81_500LT

    3 Pages

Archived catalogs