Catalog excerpts
LINSEIS / JASCO Thermal balance/FTIR // Evolved Gas Analysis EGA with TG / FTIR coupling technique This instrument consists of a horizontal Linseis balance series L81 which is coupled wi th a JASCO FTIR spectrometer series 460. This combination of 2 instruments enables to measure the change of weight over temperature and the evolved gas analysis by means of the JASCO FTIR in a temperature range from –150 up to +500°C. Other temperature r anges up to 1550°C are also possible by using a different type of furnace. The used Linseis thermo balance L81 has a horizontal measuring system which can measure weight changes with a resoluti on of 1 microgram. The furnace is a low temperature furnace which can go as low as –150°C by use of liquid nitrogen. The maximum temper ature is 500°C. The sample holder is made out of quar tz and has a relatively large volume of 3ml. The samples are placed i n the sample holder and are usually solids or powders.
Open the catalog to page 1By use of a manual gas control box two different gases can be applied to the sample and the gas stream can be controlled. A manometer is used to control the pressure on the measuring system. It is scanning the incoming gases with different wave length and measures absorption spectra. These spectra are stored in the computer and are then compared with existing libraries to determine what the evolved gases are. There are a lot of different libraries available that can be purchased for different applications. As standard a general library with 8000 different spectra is delivered with the...
Open the catalog to page 2Details of the Thermal balance L81 Details of the horizontal quartz glass measuring system L40/3052 2 times gas control station with integrated manometer which display the system pressure FTIR - gasanalysis system ( FTIR 460 plus ) Low temperature furnace with temperature range -150°C up to 500 °C, with coupling to a FTIR gasanalysis system
Open the catalog to page 3All Linseis Thermal Analysis catalogs and technical brochures
-
Linseis Couplings Overview
12 Pages
-
Simultaneous Thermal Analysis
24 Pages
-
Thermogravimetric Analyzer
20 Pages
-
Linseis Dilatometer
5 Pages
-
L74 Optical Dilatometer
7 Pages
-
Linseis Laser Dilatometer
4 Pages
-
LZT
9 Pages
-
Chip-DSC 100 and Chip-DSC 10
15 Pages
-
Linseis Quattro Dilatometer
1 Pages
-
L75 PT V Cryo Dilatometer
5 Pages
-
LINSEIS DATAGRAPH II series
2 Pages
-
Couplings / Gas Analysis
12 Pages
-
STA PT1600 TG-DSC/DTA
6 Pages
-
STA PT1000 TG-DSC
8 Pages
-
Analyse thermomécanique ATM
8 Pages
-
Strip Chart Recorder Series
2 Pages
-
LSR3 Seebeck Resistivity
6 Pages
-
Heat Flow Meter HFM
8 Pages
-
L78 / RITA (DIL Dilatometer)
8 Pages
-
Temperature Loggers, Temp101
2 Pages
-
CR4 Series circular recorder
3 Pages
Archived catalogs
-
Paperless/Videographic Recorders
3 Pages