L78 Rita Quenching Dilatometer
8Pages

{{requestButtons}}

Catalog excerpts

L78 Rita Quenching Dilatometer - 1

QUENCHING DILATOMETER RITA L78

Open the catalog to page 1
L78 Rita Quenching Dilatometer - 2

This practice is based upon the principle that, during heating and cooling of steels, dimensional changes occur as a result of both thermal expansions associated with temperature change and phase transformation. In this practice, sensitive high-speed quenching dilatometer equipment is used to detect and measure the changes in dimension that occur as functions of both time and temperature during defined thermal cycles. The resulting data are converted to discrete values of strain for specific values of time and temperature during the thermal cycle. Strain as a function of time or temperature,...

Open the catalog to page 2
L78 Rita Quenching Dilatometer - 3

Operation Method Operation Method of Quenching Dilatometer A solid or hollow sample is continuously heated to a certain temperature plateau. At this plateau a continuous cooling is started. The cooling is repeated at different (linear or exponential) cooling rates. The phase transformations occurring in the different cooling cycles are indicated by the measured change of length. An array of cooling curves with different cool down cycles represents a continuous or isothermal TTT diagram (Time Temperature Transformation diagram). Start and stop of the transformation define the fields of e.g....

Open the catalog to page 3
L78 Rita Quenching Dilatometer - 4

Software All LINSEIS thermo analytical instruments are PC controlled. The individual software modules exclusively run under Microsoft® Windows® operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The 32 bit software incorporates all essential features for measurement preparation, execution, and evaluation of a Dilatometer run. Thanks to our specialists and application experts, LINSEIS was able to develop comprehensive easy to understand user friendly application software. TA - WIN Quenching Software Module LINSEIS has...

Open the catalog to page 4
L78 Rita Quenching Dilatometer - 8

LINSEIS GmbH Vielitzerstr. 43 95100 Selb Germany Tel.: (+49) 9287–880 - 0 Fax: (+49) 9287–70488 E-mail: info@linseis.de LINSEIS Inc. 109 North Gold Drive Robbinsville, NJ 08691 USA Tel.: (+1) 609 223 2070 Fax: (+1) 609 223 2074 E-mail: info@linseis.com Products: DIL, TG, STA, DSC, HDSC, DTA, TMA, MS/FTIR, In-Situ EGA, Laser Flash, Seebeck Effect Services: Service Lab, Calibration Service